Technical publication for information purposes edited by FERMAX ELECTRÓNICA S.A.U. FERMAX ELECTRÓNICA applies a continuous improvement policy, therefore t reserves the right to modify the contents of this document, as well as the product, features hereof at any time and without prior notice. Any modification will be reflected in ubsequent editions of this document.
Product Introduction
1.1 Overview
Functions Introduction
- Call apartment
- Open door, relay delay settings
- Connect exit button
- Speech message for release lock
- Door opened alarm
- Tamper alarm
- Alarm management by access control (only panel with proximity reader)
2.1 Call Apartment
Visitor pushes the pushbutton for calling in the 1W Panel, the ring back tone
will be sent, meanwhile, the monitor will ring. The monitor will show video
and can have a conversation after answer, then release the lock.
2.2 Mifare Reader (Only panel with proximity reader)
Residents can access their corresponding entrance by bypassing the authorized
Mifare card when the card closes the reader, the door will open and sent a
speech message if succeeded.
Configuration via Web Server
The 1W panel has an integrated web server, which allows configuring of the
parameters. This web server is accessed via the panel’s IP address.
The browser opens with the configured IP address of the panel. A screen opens
requesting a username and password.
Default IP: 10.1.1.2
Username: admin
Password: 123456
3.1 Device Information
The following information is displayed: Device name, firmware version, MAC
address, IP address of the panel.
3.2 General Settings
TYPE 1W PANEL
BLOCK: Block number of the 1W panel, between 001 and 999 (default option
1).
APARTMENT: Apartment number communicates with 1W panel, between 0001 and
9899 (default option 101).
DEVICE NO. : Panel Number, between 1 and 9 (default option 1).
DEVICE TAG : Text to be shown to the monitor and another concierge.
LANGUAGE: Select the desired language for the drop-down options (default
option ENGLISH). Refresh the webpage after changing the language.
PANEL VOLUME: Select the desired value between 1 and 6, (default option
4). The conversation volume is common for uplink and downlink.
DOOR OPEN VOICE: Enables or disables the speech when the door lock is
released. If the speech is disabled, no speech in the panel will sound when
the lock is released. Enabled by default.
VIDEO RESOLUTION: In order to fit the different types of monitors. The
default value is 640×480 is to be used usually.
SIP DIVERT MODE:
PARALLEL CALL: When the panel calls the resident, the monitor and the call
divert APP ring at the same time. Once one terminal answers the call the other
one stops ringing.
SEQUENTIAL CALL : When the panel calls the resident, the monitor will
ring for about 30s if no answer, the call divert APP will start to ring.
DATE FORMAT: Date format.
DATE: Setting the date of the panel.
TIME: Setting the time of the panel.
TIME ZONE : Setting the time zone of the panel. Select local time zone
and save.
If the project has no management software the installer can set the date,
time, and time zone manually. If the project has management software, the date
and time of the panel will synchronize automatically with the management
software. If the panel has access to the internet, the date and time of the
panel will also synchronize with an internet time server.
NOTE :
Do not use the TIME ZONE setting if the panel is connected to the Internet or
Management Software.
Date and time can’t be saved after power loss, the time zone and date
format can be saved.
3.3 Network Settings
MEET allows the installer to define the IP range according to the project
needs and make the network management easier. MEET panel network mode is the
static model. Ensure that each device has a unique IP address in the same
installation. The devices (digital panel, monitor, and guard unit) will show
IP conflict if the same IP is used on the same LAN.
IP: IP address of the panel (default option 10.1.1.2).
MASK: Subnet mask of the panel (default option 255.0.0.0).
GATEWAY: Default gateway of the panel (default option 10.254.0.1).
DNS: DNS of the panel (default option 8.8.8.8).
SOFTWARE IP: IP address of PC where MEET management software is
installed. (default option 10.0.0.200).
SW. PIN : The pin code is to be used when the panel is registered in MEET
management software.
3.4 ACC
DOOR RELAY TIME: Time that the lock-release relay remains active (1-9s
optional).
OPEN DOOR DELAY: Time delay between door lock command is sent, and door
lock relay is activated. The delay time is useful when the lock is not close
to the panel (0-9s optional).
ADMIN CARD: Master card registered to enroll additional prox cards. When
there is no management software enter 0000 if you do not know the ID of the
admin card. The first prox card detected by the reader will act as an
admin/master card the card of the resident can be added afterward. If this
method is used, register the resident proximity id numbers on the cards.
DISARM BY CARD: When the card opens the door, the alarm status of the
monitor corresponding unit can change to HOME mode.
ACC PIN: Without function.
3.5 SIP Settings
ENABLE SIP: Enable or disable the sip function.
SEARCH SIP STATUS : this button appears when enabling the SIP function,
show SIP
REGISTERED if the panel registered successfully or SIP REGISTER FAILED if
the panel registered unsuccessfully.
SIP SERVER : SIP server IP address.
DOMAIN: Sip server domain.
OUTBOUND: Some servers are used when NAT is active on the router.
STUN IP: Audio and video NAT traversing public network server IP.
STUN PORT : The port of audio and video NAT traversing the public network
server.
H.264: Video coding parameters.
SIP USER: The username of the sip account.
SIP PASS: The password of the sip account.
CONVERSATION, RING TIME: No function.
NOTE:
When the panel is used as a sip device, use the quick dial to call SIP devices
or receive the calling of other SIP devices, the SIP function has to be
enabled.
3.6 Advanced Settings
The quick dial is associated with an MIO monitor, guard unit, or sip terminal.
QUICK DIAL : Enable or disable the quick dial function.
NOTE: The panel type does not be used 1W panel if you enable quick dial.
URL : if call device of the MEET system, URL: sip: sip account @ IP
address of MEET device, the sip account is optional. If call SIP device, URL:
sip: sip account @ IP address of sip server
ONU(GPON): Enable or disable the SIP penetration firewall function.
3.7 Pincode Settings
This allows changing the pin code of the webserver login.
3.8 Restore
RESTORE FACTORY SETTINGS: All the settings are restored to the factory
settings.
The IP address will be changed to the default IP: 10.1.1.2
REBOOT DEVICE: The guard unit will be restarted and will keep all the
previous settings.
Installation
4.1 Installation height
4.2 Installation Step Diagram
○,1Flush box install. ○,2Base flush box depth adjustment hook. ○,3The upper part of the panel is stuck in, then move the panel to the flush box
○,4Move the slider of the panel and fix the two screws, when installing, pay attention to the reservation of the 1.7CM space around the door to move the slide cover.
4.3 Connectors
- 10/100Mbps RJ45 Port
- +12V, —: 12Vdc Power Input
- NC, C, NO : Relay contacts for release lock
- EXIT, —: Exit button
- —, DS : Door-open sensor
- 485+, 485- : RS485 port
4.4 Technical Parameters
Dimensions
Panel (mm): 118 (W) × 183(H) × 49(D)
Flush box (mm): 105(W) × 172.5(H) × 63(D)
Power supply: 12Vdc
Standby current: 125mA
Working current: 250mA
Camera pixel: 1 megapixels
visual angle: Vertical 72º, Horizontal 54º
Minimum illumination: 0.5Lux
Maximum conversation time: 120s
Door relay time: 1-9s
Door delay time: 0-9s
Door sensor time: 120s
Block: 001-999
Apartment: 0001-9899
Maximum number per home: 9
Operating temperature: -40~70℃
Relative humidity: 20%~93%, without condensation
RADIOFREQUENCY MODULE. EC DECLARATION OF CONFORMITY:
FERMAX ELECTRÓNICA, S.A.U. declares that this product complies with the
requirements in
the RED 2014/53/EU Directive “Radiofrequency equipment”.
https://www.fermax.com/intl/en/pro/documents/technical-documentation/DT-13
-declarationsof-conformity.html
Radiofrequency module: Frequency: 13.56MHz / Maximum Power: 3,90 dBm,equivalent to 2,45mW.