FERMAX 970188d V06_24 Kin Panel User Guide
- September 9, 2024
- FERMAX
Table of Contents
FERMAX 970188d V06_24 Kin Panel
Product Information
Specifications
- Power Input: 12 Vdc
- Output: Electric lock control relay output
Product Usage Instructions
Connections
Ensure proper power input and output connections for the device.
- Power Input: Connect a 12 Vdc power supply. Use LAN PoE if available.
- Output: Connect to the electric lock control relay output.
Basic Diagrams
Refer to the basic diagrams provided in the manual for different connection
setups using a PoE switch or no PoE switch.
Basic Programming from a PC
Follow these steps for basic programming from a PC:
- Access the device configuration by dialing 9999.
- Save the settings after making changes.
On-Screen Information
You can view basic information about the panel settings on the screen by
following these steps:
- Dial 9999.
- The screen will display information about the panel settings.
FAQ
-
Q: What should I do if the device is not powering on?
A: Check the power input connections and ensure the correct voltage is being supplied. Check the power supply unit for any faults. -
Q: How can I reset the device to default settings?
A: Refer to the user manual for instructions on resetting the device to default settings. Typically, there might be a reset button or a specific code to enter for this purpose.
CONNECTIONS
-
POWER INPUT: 12 Vdc power supply for the cases where no LAN PoE is available.
-
OUTPUT: Electric lock control relay output.
- NC: Normally closed contact.
- NO: Normally opened contact.
- C: Common.
NOTE: NC & C contacts are internally duplicated.
-
EX PROXIMITY:
- (WD0-WD1) Wiegand input/output.
- (+5V, -) 5 Vdc auxiliar output.
-
EXIT BUTTON/FIRE/DOOR SENSOR:
- (EXIT, -) Connections for the indoor button.
- (FIRE, -) Input for fire alarm & block doors unlock contacts.
- (DS, -) Connection for door opened sensor.
-
RS485: Output for Ref.1491/Ref.1490/Ref.1494/Ref.9545 module.
-
RJ 45 NETWORK: RJ 45 LAN connection.
BASIC DIAGRAMS
Basic diagram using Switch PoE.
Use a power supply adapted to the electric lock voltage & current.
Basic diagram using no PoE switch
- Supply the panel by means of a FERMAX Ref. 4813 (12 Vdc 2A) power supply.
- Use a power supply adapted to the electric lock voltage & current.
- Do not power the panel and the electric lock from the same power supply.
BASIC PROGRAMMING FROM A PC
- Panel programming is done exclusively through a PC connected to the same LAN, through a web browser (Chrome preferably), accessing the IP of the panel.
- The default IP is 10.1.0.1.
- The PC must have an IP of the same range as the IP of the panel.
Example:
In the case that the IP of the panel is 10.1.0.1, the IP of the PC has to be
of type 10. X.X.X with a subnet mask 255.0.0.0
- Assign, as a minimum, the parameters indicated in the following table.
- It is necessary to carry out a previous planning of the installation, to define the parameters to assign to each device.
To login, identify yourself with the username and password.
Default value:
- Username: admin
- Password: 123456
GENERAL
- Panel type: GENERAL, BLOCK or 1W PANEL
- Panel number: 1-999
- Device number (panels in the same block): 1-99
- Language: Choose from the available languages.
Confirm with SAVE
NETWORK
Indicate the network parameters assigned to this panel:
- Panel IP address
- Subnet mask
- Gateway
- DNS
Confirm with SAVE
ON-SCREEN INFORMATION
It is possible to get basic information on the equipment configuration through the screen.
- Dial 9999, followed by the telephone icon
- The screen will display information about panel settings:
- Firmware version
- GENERAL settings
- Serial number
- IP address
- MAC
Contact Information
FERMAX
- Avd. Tres Cruces, 133 46017 Valencia Spain
- For extended information, visit www.fermax.com.
- Contact: tec@fermax.com.