FERMAX 1445 MEET KIN Touch Panel User Manual

June 4, 2024
FERMAX

FERMAX 1445 MEET KIN Touch Panel

http://www.fermax.com MEET DIGITAL VIDEO Panel manual available at https://www.fermax.com/qr/meet/ Copyright Notice Fermax and Fermax MEET panel are trademarks of Fermax Electronica S.A.U. registered in the European Union and other countries. © FERMAX ELECTRÓNICA S.A.U., 2018.

Product Introduction

Overview

FERMAX-1445-MEET-KIN-Touch-Panel-fig-1

Panel Display Screen

Functions Introduction

  • Call apartment
  • Call guard unit
  • Call volume settings
  • Door opening, relay delay settings
  • Connect exit button
  • Speech
  • Door opened and tamper alarm
  • Lift control (Only when installed)
  • Access Code
  • Mifare reader
  • Alarm management by access control
  • Face Recognition for release lock

Call Apartment

Block Panel call apartment

  • Visitors need enter apartment number followed by to confirm. For example, if the resident  lives in apartment 2601, the visitor should enter: 2601 and press

General Entry Panel call apartment

Visitors need to enter block number followed by a 4 digits apartment number followed by to confirm. For example, if the resident lives in block 3 apartment 2601, the visitor shall enter: 32601 and press

Call Guard Unit

Block Panel Call Guard Unit

The visitor or resident can call the guard unit by touch concierge icon , then select the concierge that they want to call .This call can be made from all Block Entry Panels.

General Entry Panel Call Guard Unit

The visitor or resident can call the guard unit by touch concierge icon , then select the concierge that they want to call .This call can be made from all General Entry Panels.

Access Code

Press ACCESS CODE icon to access code function, entering the access code followed by KEY icon to confirm. If the access code is correct the door will open and release the lock. You can enable or disable the function at web of the panel. The access code to be defined at web of the panel, Maximum access code 8.

Face Recognition

Press FACE RECOG icon to key access face recognition function, the camera of the panel will start to read the face information. If the face data is authorized, the door will open and release the lock. The face data is to be added through the management software. Maximum face data 10000.

Mifare Reader

Resident can access to their corresponding entrance by passing their authorized Mifare card, the door will open and release the lock. The Mifare card data is to be added through management software, Maximum of 100,000 Mifare cards.

About

Enter code 9999 followed by icon to confirm, The ABOUT information will show.

You can get information about the device name, firmware version, IP address, MAC address.

Installation

Connectors

FERMAX-1445-MEET-KIN-Touch-Panel-fig-12

  • 10/100Mbps RJ45 Port.
  • +, —: 12Vdc Power Input.
  • C, NO, NC: Relay contacts for release lock, the double terminals are the same connection.
  • +5V, —, WD0, WD1: Wigand-26 protocol output or input.
  • BS, —: Exit button.
  • —, SP: Door-open sensor.
  • 485+, 485-: To lift control gateway, F01491 (4 relay module).

Technical Parameters

Dimensions

  • Panel (mm): 185(W) ×405(H) ×53(D)
  • Power supply: 12Vdc/POE
  • Standby current: 330mA
  • Working current: 500mA

Technical specifications of the display:

  • Size: 10 inch
  • Format: 16:9
  • Resolution: 1024*600
  • Camera pixel: 1.2 megapixels
  • 90o visual angle: Vertical 72º, Horizontal 54º
  • Minimum illumination: 0.5Lux
  • Maximum conversation time: 120s
  • Door relay time: 1-9s
  • Door delay time: 0-9s
  • Door sensor time: 120s
  • IC cards: 100,000
  • Face data: 10000
  • Operating temperature: 40℃
  • Relative humidity: 20%~80%, without condensation

FCC Warning

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Caution:
Products can only be used below 2000m altitude For the following equipment: Product Name: KIN TOUCH PANEL Model: 1445 1446 Brand Name: FERMAX FERMAX (SHANGHAI) ELECTRONICS CO., LTD. E-mail: [email protected] hereby declares that this [Name: KIN TOUCH PANEL, Model: 1445,1446] is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the internet address: www.xxx.com This product is intended for sale and application in a business environment. RED Article 10 2

  • This product can be used across EU member states RED Article 10 10
  • The product is class 1 product, No restrictions

NFC:
Frequency Range: 13.56MHz Radiated H-Field: -12.6dBuA/m(@10m)

Installation

Installation height

FERMAX-1445-MEET-KIN-Touch-Panel-fig-13

Installation Guide Diagram

FERMAX-1445-MEET-KIN-Touch-Panel-fig-14

  1. Flush box install.
  2. Base flush box depth adjustment hook.
  3. The upper part of the panel is stuck in, then move the panel to the flush box.

FERMAX-1445-MEET-KIN-Touch-Panel-fig-15

Move the slider of the panel and fix the two screws. When installing, pay attention to the reservation of the 2 CM space around the door to move the slide cover.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FERMAX User Manuals

Related Manuals