The PSU-1000X is a high-performance power supply unit designed for gaming PCs and workstations. It comes with a range of connectors to support various components and ensure stable power delivery.

Specifications

  • Product No.: PSU-1000X
  • Dimensions: 150mm x 86mm x 160mm
  • Weight: 2.5kg
  • Input Voltage: 100-240V
  • Output Power: 1000W

Product Usage Instructions

Component List
Before installing, ensure you have all the components listed:

  • PSU x 1
  • ATX Motherboard 24 pin x 1 60cm
  • ATX12VO Motherboard 10 pin x 1 60cm
  • CPU 4+4 pin x 2 70cm
  • 12V-2×6 12+4 pin x 1 60cm
  • PCIe 6+2 pin x 3 60cm
  • SATA (4 connectors) x 2 – 45cm, 15cm, 15cm, 15cm
  • 4P Molex (4 connectors) x 1 – 45cm, 15cm, 15cm, 15cm
  • Mounting Screws x 4
  • AC Cord x 1
  • PSU Tester x 1

Installation Instructions

  1. Ensure the main plug serves as the disconnect device.
  2. Connect the apparatus to a main socket outlet with a protective earthing connection.
  3. Follow the component list to connect the appropriate cables to your PC components.
  4. Use the included PSU tester to verify proper functionality before connecting to your system.

D.F. Switch and I/O Switch Functions
The D.F. switch initiates the Dust-Free Rotation Function for fan dust removal, while the I/O switch serves as the individual PSU ON/OFF switch.

Follow ENERMAX on social media for the latest information and show us your build with hashtag #ENERMAX

Product Notice

Only a technician, authorized by ENERMAX, is allowed to perform maintenance service! Warranty is subject to void under unauthorized attempt to open the power case or modification of any kind, even attempted only, of the power supply or its components!

ENERMAX will not be responsible for damages caused by the following situations:

  • Opening of the PSU case and/or modification of any component or cable without ENERMAX written authorization.
  • Ignoring the connector’s wrong insertion prevention design by attaching a connector to a device in the wrong orientation.
  • Connecting too many devices to one cable unit by using an additional adaptor (Y cables).
  • The serial number label or warranty seal is defaced, modified, or removed.
  • Damage caused by natural phenomena or uncontrollable forces, such as lightning, flooding, fire, earthquake, etc.
    • The main plug is used as the disconnect device, the disconnect device shall remain ready for operation.
    • The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.

This ENERMAX Technology Corporation product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. The warranty length may be different in diverse regions based on local policy. ENERMAX Technology Corporation agrees to repair or replace the product, at its option and at no charge, if, during the warranty period, it is returned to the nearest ENERMAX Technology Corporation subsidiary/agent with all shipping charges prepaid and bearing a return merchandise authorization (RMA) number, and if the inspection reveals that the product is defective. Charges for removing or installing the product are excluded under the terms of this warranty agreement. This warranty shall not apply to any product, that has been subject to connection to a faulty power source, alteration, negligence, or accident, or to any product, which has been installed other than by these instructions. In no event shall ENERMAX Technology Corporation, its subsidiaries, or agents be liable for damages for a breach of warranty in an amount exceeding the purchase price of this product!

We would like to thank you for your support. Please visit our website at:

Global:

Taoyuan :

Germany:

Korea:

If you have any questions or problems with our products, please contact our support team at www.enermax.com/support.

Component List

Product Introduction

The actual product may vary in different regions.

Test Your PSU Before You Connect to the PC System

  1. Take the AC cord and the motherboard cable.
  2. Insert the 18-pin and 10-pin connectors to the PSU.
  3. Plug in the 24-pin connectors to the tester.
  4. Plug in the AC cord and set the I/O switch to “I” to turn on the PSU.
  5. PSU fan will spin clockwise at the beginning to clean itself and then turn counterclockwise for several seconds, and stop to activate the semi-fanless function.

Installation-Cable

ATX Motherboard 24-pin
Connect the 24-pin motherboard power.

ATX12VO Motherboard 10-pin
Connect the 10-pin motherboard power.

CPU 4+4 pin
Connect the 4+4 pin CPU power.

12V-2×6 12+4 pin
Connect the 12+4 pin connector to your GPU as required.

PCIe 6+2 pin
Connect the PCIe connectors to your GPU as required.

SATA
Connect the SATA as needed.

4P Molex
Connect the 4P molex to your fans as required.

Warning
Please only use the modular cables provided in your ENERMAX power supply package. Do NOT use other cables to prevent pin configuration damage to your system and your power supply.

How to Install 12V-2×6 Properly

Please avoid vertically or horizontally cable bending too close to the connectors. We suggest a minimum distance of 35mm from the connectors before bending.

How to Connect Cable to GPU Properly

Check the power consumption from the official GPU website before installation, and also please see the PCIe slots installation instructions below.

2 PCIe Slots

3 PCIe Slots

  • High-powered GPU are usually outfitted with two or three PCIe power connector slots.
  • ENERMAX prefers the use of two or three separate PCIe cables to connect these cards to your PSU.

Installation-PSU

Step 1

Step 2

Specification

Spec./Model EGN1200P
AC Input Voltage 100-240VAC, 50-60Hz

200-240VAC, 50-60Hz (for China)

AC Input Current| 15A-8A

8A (for China)

ATX3.1



DC Output

| | +3.3V| +5V| +12V| -12V| +5Vsb| Total Power
Rated| 20A| 20A| 100A| 0.4A| 3A| ****

1200W

Combined| 100W| 1200W| 4.8W| 15W
ATX12VO




DC Output

| | +12V| +12Vsb| Total Power
Rated| 100A| 1.5A| ****

1200W

Combined| 1200W| 18W
Environment


Temp.

| Operating: 0°C to +50°C Non-operating: -40°C to +70°C


Humidity

| Operating: 20% to 85% relative humidity (non-condensing). Non-operating: 5% to 95% relative humidity (non-condensing).
Others
Power Factor| >0.95 at full load
Cooling| One 13.5cm Dual-Ball Bearing Fan
MTBF| 100K hours minimum
Dimension| 150(W)150(D)86(H) mm

Protection

OCP
(Over Current Protection)| OCP makes sure that the output of the DC voltage rails remains within safe operating limits.
---|---
OVP
(Over Voltage Protection)| OVP shuts down the PSU when the DC outputs exceed a certain level, which is determined by the PSU manufacturer.
UVP
(Under Voltage Protection)| UVP shuts off the PSU when the voltage is under a certain standard.
OPP
(Over Power Protection)| OPP shuts off the PSU when the power drawn is between 115% ~ and 135% of the rated power.
OTP
(Over Temperature Protection)| OTP makes sure that the PSU will shut down when the internal temperature reaches a set point.
SCP
(Short Circuit Protection)| SCP makes sure that the PSU shuts down when the 3.3V, 5V, and 12V rails short to any other rail, or to ground. It also ensures that no damage should occur to the unit, or your PC’s components in the event of a short.

FAQ

Where is the 4-pin CPU connector?

The 8-pin CPU cable can be split into two 4-pin connectors.

How to connect the PSU to the GPU with 6-pin and 2-pin connectors

Combine the 6-pin and 2-pin connectors into an 8-pin connector before connecting them to the GPU.

How to connect the PSU to the motherboard

For ATX motherboards Plug in the 18-pin and 14-pin connectors to the PSU and the 24-pin to the motherboard. For ATX12VO motherboards Plug in the 14-pin connector to the PSU and the 10-pin to the motherboard.

Why does the PSU fail to power up?

Check if the CPU connectors are connected to the motherboard and PSU correctly, if not, the PSU can’t be powered up.

After installing a new GPU, the PC system crashes frequently.

The PSU may be inadequate for your new GPU. Please refer to our PSU calculator tool on ENERMAX’s official website.

The fan doesn’t continue spinning after the PSU is turned on for several seconds.

With the Dust-free Rotation(DFR) function, the fan will start spinning clockwise for several seconds in the beginning to clean itself and then turn counterclockwise for a few more seconds. Eventually, it will pause to switch to fanless mode.

Can I open the power case for maintenance?

Only authorized technicians are allowed to perform maintenance services. Unauthorized attempts to open or modify the power supply will void the warranty.

Where can I get support for technical issues?

For technical support, please visit the ENERMAX website and contact the appropriate support team based on your region.

Declaration of the Presence Condition of the Restricted Substances Marking

Unit Restricted substances and their chemical symbols
Lead (Pb) Mercury (Hg)
Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE)
case
wire
The main circuit board
Resistor
Capacitance
二 Diode
SMD DIODE
IC
Transformer/coil
FUSE
Heat sinks
Mylar insulation slices
AC Switch and socket
Fan
Plastic parts

Packaging materials

| ○| ○| ○| ○| ○| ○
Note 1: “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of the presence condition.

Note 2: “○” indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.

Note 3: The “-” indicates that the restricted substance corresponds to the exemption.

Contact Information

  • © 2024, ENERMAX Technology Corporation, 2F-1, No. 888, Jing-Guo Road, Taoyuan City (330)
  • Tel. +886-3-316-1675
  • Fax. +886-3-346-6640

All rights reserved. Actual products and accessories may differ from illustrations. Information in this manual is subject to change without prior notice. Printing errors and omissions excepted. All trademarks, registered trademarks, and/or product names mentioned are the property of their respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals