ENERMAX REVOLUTION ATX3.0 Power Supply User Manual

June 12, 2024
ENERMAX

REVOLUTION ATX3.0 Power Supply
User Manual

Precaution Notice

Only a technician, authorized by ENERMAX, is allowed to perform maintenance service! Warranty is subject to void under unauthorized attempt to open the power case or modification of any kinds, even attampted only, of the pawer supply or its components!
ENERMAX will not be responsible for damages caused by following sudations:

  • Opening of the PSU case and/or modification of any component or cable without ENERMAX written authorization.
  • Ignoring connector’s wrong insertion prevention design by attaching a connector to a device in wrong orientation.
  • Connecting too many devices to one cable unit by using additional adaptor (Y cables) .
  • The serial number label or warranty seal is defaced, modified, or removed.
  • Damage caused by natural phenomena or uncontrollable forces, such as lightning, flooding, fire, earthquake, etc.

Main plug is used as the disconnect devious, the disconnect device shall remain ready for operating.
Apparatus shall be connected to a MAIINS socket outlet with a protective earthing connection.
This ENERMAX Technology Corporation product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of purchase.
ENERMAX Technology Corporation agrees to repair or replace the product, at its own option and at no charge, if, during the warranty period, it is returned to nearest ENERMAX Technology Corporation subsidiary/agent with all shipping charges prepaid and bearing a return merchandize authorization (RMA) number, and if inspection reveals that the product is defective. Changes for removing or installing the product are excluded under the lerps of this warranty agreement. This warranty shall nat apply to any product, which has been subject to connection to a faulty power source, alteration, negligence, or accident, or to any product, which has been installed other than in accordance with these instructions. In no event shall ENERMAX Technology Corporation, or ts subsidiaries, or agents be liable for damages for a breach of warranty in an amount exceeding the purchase price of this product!
If you are uncertain whether or not your ENERMAX PSU is defective, please contact your dealer reseller for support!
Web Site: htip://wwew.enermax.com
E-mail: [email protected]
© 2023, ENERMAX Technology Corporation,
2F-1 , No. 888, Jing-Guo Road, Taoyuan City (330),
Tel. +886-3-316-1675, Fax. +686-3-346-6640
All rights reserved. Actual product and accessories may differ from Illustrations. Information in this manual is subject to change without prior notice. Printing errors and omissions excepted. All trademarks, registered trademarks and/or product names mentioned are the property of their respective owners.

ENERMAX REVOLUTION ATX3.0 Power Supply - Parts

Name of Parts

  1. Output cable: Please check “Cables & Connectors” section
  2. 13.5cm fan
  3. AC inlet*
  4. 1/0 switch”: individual PSU on/off switch (I= ON, O=OFF)
    *When assemble or maintain the system, please remove AC cord from AC inlet.
  5. Semi-finless

Specifications

Spec. Model ERA850EVVT ERA1000EVVT ERAl200EINT
AC Input Voltage 100-240VAC, 50-60Hz 100-240VAC, 50-60Hz 100-240VAC,

50-60Hz
AC Input Current| 10-5A| 13A| 15.0A
DC Output
| Rated| Combined| Rated| Combined| Rated| Combined
+3.3V| 22A| 120W| 22A| 120W| 22A| 120W
+5)/| 22A| 22A| 22A
+12V| 70.8A| 849.6W| 83.33A| 1000W| 100A| 1200W
-12V| 0.3A| 3.6W| 0.3A| 3.6W| 0.3A| 3.6W
+5Vsb| 3A| 15W| 3A| 15W| 3A| 15W
Total Power| 850W| 1000W| 1200W
Environment
Temp.| Operating : 0°C to +50°C
Non-operating : -20°C to +70°C
Humidity| Operating : 20% to 90% relative humidity (non-condensing).
Non-operating : 5% to 95% relative humidity (non-condensing).
Others
Power Factor| z 0.96 at 230Vac 50Hz (Full load)
Cooling| One 13.5cm Fluid Dynamic Bearing fan
MTBF| 100K hours minimum
Dimension| 150(W)86(H)150(D) mm
Safety & EMC| cTUVus, CE, FCC, EAC, BSMI

Dear customer,
Thank you for choosing this ENERMAX REVOLUTION ATX3.0 power supply unit (PSU)! Please read this manual carefully and follow its instructions, before installing the PSU.
Please only use the modular cables provided in your ENERMAX power supply package. Do NOT use other modular cables to prevent pin configuration damage to your system and your power supply.

CABLES & CONNECTORS

| 24P Motherboard
24-pin configuration supports latest ATX PC.
---|---
| 4+4P CPU +12V,in combined mode
8-pin configuration supports dual CPU server/workstation systems and some single CPU PC systems.
| 4+4P CPU +12V,in split mode
4-pin configuration supports most ATX/BTX systems.
| 12VHPWR
12+4 pin configuration supports high-end graphic cards, which require 12VHPWR connector.
| 6+2P(8P) PCIe , in combined mode
8-pin configuration supports performance graphic cards, which require 8-pin PCIe connector.
| 6+2P(8P) PCIe , in split mode
6-pin configuration supports entry-level graphic cards, which require 6-pin PCIe connector.
| SATA
For SATA drives.
| 4P Molex #1
For devices with traditional 4P power in socket.
| b
For floppy drives.

1 If you plan to build your system with high-end, power demanding GPU cards,

please make sure that you connect all of the sockets with your power supply accurately.

COMPATIBILITY

ENERMAX REVOLUTION ATX3.0 series is compatible with:

  • Intel ATX Power Supply Design Guide v3.0 specification and downward compatible with v2.4
    This PSU does not support motherboard with ISA expansion slot, which might require -5V power. —5V has been cancelled from Intel ATX v1.3 specification onwards.
    To avoid failures and to increase lifetime of your entire PC, we suggest you to make sure that:

  • Your PC is NOT located near a radiator or any other heat producing device

  • Your PC is NOT located near a magnetic device

  • Your PC is NOT located in a moist and/or dusty and/or vibrating environment

  • Your PC is NOT exposed to direct sunshine

  • Your PC is sufficiently cooled by additional fans

We do not recommend using PC systems with finless cooling, because a potentially high inner temperature decreases stability and lifetime of all components inside your PC!

BOOTING YOUR SYSTEM

Before booting your system, please check that:

  1. All needed connectors are properly connected.
  2. AC cord is properly connected to wall plug and PSU AC inlet.
  3. Turn on the power supply by switching the I/O switch to “I”, and your system is ready.

PROTECTION, SAFETY & SECURITY

This ENERMAX PSU features multiple protections. In case of most abnormal situations, the power supply will automatically turn off to avoid potential danger to itself and other PC components. If you have any question or need support, please contact your reseller or nearest ENERMAX subsidiary/agent or ENERMAX headquarter service center.
Declaration of the Presence Condition of the Restricted Substances Marking
Declaration of the Presence Condition of the Restricted Substances Marking

Unit R esented substances and its chemical symbols
Lead (Pb) Mercury (Hg)
(Cr) Polypro Mated biphenyls
(PBS) Polybrominated Biphenyl ethers (PBDE)
case
wire
The main circuit board 0
Resistor 0
Capacitance 0
Diode
Still) DIODE
IC
Transformer 0
FUSE 0
Heat sinks 0
Mylar insulation slices 0
Switch and socket 0
Fan 0
Plastic parts 0
Packaging materials 0

Note 1 : ‘Exceeding 0.1 vet W and “exceeding 0.01 wt %” indicate that She percentage content of the restricted substance exceeds the reference percentage value of presence condition.
Note 2 : “Indicates that the percentage content of the restricted substances does not exceed the percentage of reference value of presence.
Note 3 : The “—* indicates that the restricted substance corresponds to the exemption.

Web Site: http://www.enermax.com
E-mail: [email protected]
Information in this document is subject to change without notice.
© 2023 ENERMAX Technology Corporation.
All rights reserved. Reproduction in any manner without the written permission of ENERMAX is strictly forbidden.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>