ENERMAX Revolution ATX3.0 1000W Gold Fully Modular Power Supply User Manual

May 15, 2024
ENERMAX

ENERMAX Revolution ATX3.0 1000W Gold Fully Modular Power Supply

ENERMAX-Revolution-ATX3-0-1000W-Gold-Fully-Modular-Power-Supply-
PRO

Product Information

The ENERMAX PSU is designed to provide an efficient power supply for your system. It features a variety of output cables and connectors for versatile connectivity. The PSU comes with a 13.5cm fan for cooling and an I/O switch for an individual on/off control. It is semi-fanless, ensuring quiet operation.

Specifications

Spec. Model AC Input Voltage AC Input Current
ERA850EWT 100-240VAC, 50-60Hz 10-5A
ERA1000EWT 100-240VAC, 50-60Hz 13A
ERA1200EWT 100-240VAC, 50-60Hz 15.0A

Product Usage Instructions

Name of Parts:

  1. Output cable: Please check Cables & Connectors section
  2. 13.5cm fan
  3. AC inlet
  4. I/O switch: individual PSU on/off switch (I=ON, O=OFF) *When assembling or maintaining the system, please remove the AC cord from the AC inlet.
  5. Semi-fanless operation

Usage Guidelines:

  1. When assembling or maintaining the system, always disconnect the AC cord from the AC inlet.
  2. Use the I/O switch to control the power supply – I for ON and O for OFF.

FAQ

  • Q: Can I open the power case of the PSU for maintenance?
    A: Only a technician authorized by ENERMAX should perform maintenance on the PSU. Unauthorized attempts to open the power case may void the warranty.

  • Q: How can I determine if my ENERMAX PSU is defective?
    A: If you suspect any issues with the PSU, please contact your dealer/reseller for support and guidance on troubleshooting.

  • Q: What should I do in case of natural disasters like lightning or flooding?
    A: Ensure that the main plug is used as the disconnect device and remains ready for operation. In such situations, prioritize safety and follow all necessary precautions.

  • Q: Where can I find more information about ENERMAX products?
    A: Visit the official website at www.enermax.com or contact via email at enermax@enermax.com.tw for inquiries.

  • Q: Are there any restrictions on modifications to the PSU?
    A: Any modifications or attempted modifications to the power supply or its components, even if unsuccessful, may void the warranty. Always seek professional assistance for any maintenance needs.

Precaution Notice

Only a technician, authorized by ENERMAX, is allowed to perform maintenance service! Warranty is subject to void under unauthorized attempt to open the power case or modification of any kind, even attempted only, of the power supply or its components!

ENERMAX will not be responsible for damages caused by the following situations:

  • Opening of the PSU case and/or modification of any component or cable without ENERMAX’s written authorization.
  • ignoring the connector’s wrong insertion prevention design by attaching a connector to a device in the wrong orientation.
  • Connecting too many devices to one cable unit by using an additional adaptor (Y cables).
  • The serial number label or warranty seal is defaced, modified, or removed.
  • Damage caused by natural phenomena or uncontrollable forces, such as lightning, flooding, fire, earthquake, etc.
  • The main plug is used as the disconnect device, the disconnect device shall remain ready for operation.
  • The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.

This ENERMAX Technology Corporation product is warranted to be free from defects in material and workmanship for five (5) years from the date of purchase. ENERMAX Technology Corporation agrees to repair or replace the product, at its option and no charge, if, during the warranty period, it is returned to the nearest ENERMAX Technology Corporation subsidiary/agent with all shipping charges prepaid and bearing a return merchandise authorization (RMA) number, and if the inspection reveals that the product is defective. Charges for removing or installing the product are excluded under the terms of this warranty agreement. This warranty shall not apply to any product, which has been subject to connection to a faulty power source, alteration, negligence, or accident, or to any product, which has been installed other than by these instructions. In no event shall ENERMAX Technology Corporation, its subsidiaries, or agents be liable for damages for a breach of warranty in an amount exceeding the purchase price of this product!

If you are uncertain whether or not your ENERMAX PSU is defective, please contact your dealer/reseller for support!
Web Site: http://www.enermax.com
E-mail: enermax@enermax.com.tw

© 2023, ENERMAX Technology Corporation, 2F-1, No. 888, Jing-Guo Road, Taoyuan City (330),
Tel. +886-3-316-1675
Fax. +886-3-346-6640

All rights reserved. Actual products and accessories may differ from Illustrations. Information in this manual is subject to change without prior notice. Printing errors and omissions excepted. All trademarks, registered trademarks and/or product names mentioned are the property of their respective owners.

Name of Parts

ENERMAX-Revolution-ATX3-0-1000W-Gold-Fully-Modular-Power-
Supply-1

  1. Output cable: Please check “Cables & Connectors” section
  2. 13.5cm fan
  3. AC inlet*
  4. *I/O switch:* individual PSU on/off switch (I= ON, O=OFF)
    When assemble or maintain the system, please remove AC cord from AC inlet.
  5. Semi-fanless

Specifications

ENERMAX-Revolution-ATX3-0-1000W-Gold-Fully-Modular-Power-
Supply-2

Dear customer,
Thank you for choosing this ENERMAX REVOLUTION ATX3.0 power supply unit (PSU)! Please read this manual carefully and follow its instructions, before installing the PSU. Please only use the modular cables provided in your ENERMAX power supply package. Do NOT use other modular cables to prevent pin configuration damage to your system and your power supply.

CABLES & CONNECTORS

ENERMAX-Revolution-ATX3-0-1000W-Gold-Fully-Modular-Power-
Supply-2 ENERMAX-Revolution-
ATX3-0-1000W-Gold-Fully-Modular-Power-Supply-4

1 If you plan to build your system with high-end, power demanding GPU cards,

please make sure that you connect all of the sockets with your power supply accurately.

COMPATIBILITY

ENERMAX REVOLUTION ATX3.0 series is compatible with:

  • Intel ATX Power Supply Design Guide v3.0 specification and downward compatible with v2.4

This PSU does not support motherboard with ISA expansion slot, which might require –5V power. –5V has been cancelled from Intel ATX v1.3 specification onwards.

To avoid failures and to increase lifetime of your entire PC, we suggest you to make sure that:

  • Your PC is NOT located near a radiator or any other heat producing device.
  • Your PC is NOT located near a magnetic device.
  • Your PC is NOT located in a moist and/or dusty and/or vibrating environment.
  • Your PC is NOT exposed to direct sunshine.
  • Your PC is sufficiently cooled by additional fans.

We do not recommend using PC systems with fanless cooling, because a potentially high inner temperature decreases stability and lifetime of all components inside your PC!

BOOTING YOUR SYSTEM

Before booting your system, please check that:

  1. All needed connectors are properly connected.
  2. AC cord is properly connected to wall plug and PSU AC inlet.
  3. Turn on the power supply by switching the I/O switch to “I”, and your system is ready.

PROTECTION, SAFETY & SECURITY

This ENERMAX PSU features multiple protections. In case of most abnormal situations, the power supply will automatically turn off to avoid potential danger to itself and other PC components. If you have any question or need support, please contact your reseller or nearest ENERMAX subsidiary/agent or ENERMAX headquarter service center.

Web Site: http://www.enermax.com
E-mail: enermax@enermax.com.tw
Information in this document is subject to change without notice. © 2023 ENERMAX Technology Corporation. All rights reserved. Reproduction in any manner without the written permission of ENERMAX is strictly forbidden.

Declaration of the Presence Condition of the Restricted Substances Marking:

Unit Restricted substances and their chemical symbols
Lead (Pb) Mercury (Hg)
Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE)
case
wire
The main circuit board
Resistor
Capacitance
Diode
SMD DIODE
IC
Transformer /coil
FUSE

| ○| ○| ○| ○| ○
Heat sinks| ○| ○| ○| ○| ○| ○
Mylar insulation slices| ○| ○| ○| ○| ○| ○
AC Switch and socket| ○| ○| ○| ○| ○| ○
Fan| ○| ○| ○| ○| ○| ○
Plastic parts| ○| ○| ○| ○| ○| ○
Packaging materials| ○| ○| ○| ○| ○| ○
Note 1: “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.

Note 2: “○”indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.

Note 3: The “-” indicates that the restricted substance corresponds to the exemption.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>