Product Information

Specifications:

  • Product Name: PSU (Power Supply Unit)
  • Manufacturer: ENERMAX
  • Components: See Component List below
  • Website: ENERMAX Global Website

Component List :

  • A PSU x 1
  • F SATA (4 connectors) x 2 – 45cm, 15cm, 15cm, 15cm
  • B Motherboard 24 pin x 1 – 60cm
  • C CPU 4+4 pin x 2 – 70cm
  • D 12V-2×6 12+4 pin x 1 – 60cm
  • E PCIe 6+2 pin x 3 – 60cm
  • G 4P Molex (4 connectors) x 1 – 45cm, 15cm, 15cm, 15cm
  • H Mounting Screws x 4
  • I AC Cord x 1 *The actual AC cord depends on different areas.
  • J PSU Tester x 1

Product Usage Instructions

  • Test Your PSU Before You Connect to PC System:
    Before connecting the PSU to your PC system, use the provided PSU tester to ensure it is functioning correctly.

  • Installation-Cable:
    Refer to the Component List for cable types and lengths. Connect the appropriate cables to their corresponding components following the installation guidelines.

FAQ :

  • Q: Can I open the power case of the PSU for maintenance?
    A: Only a technician authorized by ENERMAX is allowed to perform maintenance on the PSU. Unauthorized attempts to open or modify the power supply will void the warranty.

  • Q: How do I contact ENERMAX support for product issues?
    A: For questions or problems with ENERMAX products, contact the support team through the website at www.enermax.com/support.

User Manual

Follow ENERMAX on social media for the latest information and show us your build with hashtag #ENERMAX

Product Notice

Only a technician, authorized by ENERMAX, is allowed to perform maintenance service! Warranty is subject to void under unauthorized attempt to open the power case or modification of any kinds, even attempted only, of the power supply or its components!
ENERMAX will not be responsible for damages caused by following situations:

  • Opening of the PSU case and/or modification of any component or cable without ENERMAX written authorization.
  • ignoring connector’s wrong insertion prevention design by attaching a connector to a device in wrong orientation.
  • Connecting too many devices to one cable unit by using additional adaptor (Y cables) .
  • The serial number label or warranty seal is defaced, modified, or removed.
  • Damage caused by natural phenomena or uncontrollable forces, such as lightning, flooding, fire, earthquake, etc.
  • Main plug is used as the disconnect device, the disconnect device shall remain ready for operating.
  • Apparatus shall be connected to a MAIINS socket outlet with a protective earthing connection.

This ENERMAX Technology Corporation product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. The warranty length may be different in diverse regions based on local policy. ENERMAX Technology Corporation agrees to repair or replace the product, at its own option and at no charge, if, during the warranty period, it is returned to nearest ENERMAX Technology Corporation subsidiary/agent with all shipping charges prepaid and bearing a return merchandize authorization (RMA) number, and if inspection reveals that the product is defective. Charges for removing or installing the product are excluded under the terms of this warranty agreement. This warranty shall not apply to any product, which has been subject to connection to a faulty power source, alteration, negligence, or accident, or to any product, which has been installed other than in accordance with these instructions. In no event shall ENERMAX Technology Corporation, or its subsidiaries, or agents be liable for damages for a breach of warranty in an amount exceeding the purchase price of this product!
We would like to thank you for your support. Please visit our website at: Global :

Taoyuan :

Germany:

Korea :

Component List

ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(1\) ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(2\)

Product Introduction

The actual product depends on different regions or countries.

ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(3\) ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(4\)

Product Introduction

ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(5\)

Test Your PSU Before You Connect to PC System

ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(6\) ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(7\)

  1. Take the AC cord and the motherboard cable.
  2. Insert the 18 pin and 10 pin connectors to the PSU.
  3. Plug in the 24 pin connectors to the tester.
  4. Plug in the AC cord and set the I/O switch to “I” to turn on the PSU.
  5. PSU fan will spin clockwise at the beginning to clean itself and then turn counterclockwise for several seconds, and stop to activate semi-fanless function.

Test Your PSU Before You Connect to PC System

Installation-Cable

  • Motherboard 24 pin

    • Connect the 24-pin motherboard power.

ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(8\)

  • CPU 4+4 pin

    • Connect the 4+4 pin CPU power.
  • 12V-2×6 12+4 pin

    • Connect the 12+4 pin connector to your GPU as required.
  • PCIe 6+2 pin

    • Connect the PCIe connectors to your GPU as required .
  • SATA

    • Connect the SATA as needed.
  • 4P Molex

    • Connect the 4P molex to your fans as required.

Warning
Please only use the modular cables provided in your ENERMAX power supply package. Do NOT use other cables to prevent pin configuration damage to your system and your power supply.

How to Install 12V-2×6 Properly?

ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(14\) ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(15\)

Please avoid vertically or horizontally cable bending too close to the connectors. We suggest a minimum distance of 35mm from the connectors before bending.

How to Connect Cable to GPU Properly?
Check the power consumption from the official GPU website before installation, and also please see the PCIe slots installation instruction below.

ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(16\) ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular- \(17\)

High-powered GPU are usually with two or three PCIe power connector slots. ENERMAX prefers the use of two or three separate PCIe cables to connect these cards to your PSU.

Installation-PSU ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular-
\(18\) ENERMAX-ETV850G-W-PLUS-Gold-Fully-Modular-
\(19\)

Specification


Model

Spec.

| ****

ETV750G ETV750G-W

| ****

ETV850G ETV850G-W

---|---|---
AC Input Voltage| 100-240VAC, 50-60Hz
AC Input Current| 10A
DC Output
| Rated| Combined| Rated| Combined
+3.3V| 20A| ****

100W

| 20A| ****

100W

+5V| 20A| 20A
+12V| 62.4A| 748.8W| 70.8A| 849.6W
-12V| 0.4A| 4.8W| 0.4A| 4.8W
+5Vsb| 3A| 15W| 3A| 15W
Total Power| 750W| 850W
Environment


Temp.

|

  • Operating : 0°C to +50°C
  • Non-operating : -40°C to +70°C

Humidity

|

  • Operating : 20% to 85% relative humidity (non-condensing).
  • Non-operating : 5% to 95% relative humidity (non-condensing).

Others
Power Factor| >0.98 at 230Vac 50Hz(Full load)
Cooling| One 11.5cm Dual-Ball Bearing Fan
MTBF| 100K hours minimum
Dimension| 150(W)86(H)122(D) mm
Safety & EMC| cTUVus, CE, FCC, EAC, CCC

Protection


OCP (Over Current Protection)

| OCP makes sure that the output of the DC voltage rails remains within safe operating limits.
---|---
O VP (Over Voltage Protection)| OVP shuts down the PSU when the DC outputs exceed a certain level, which is determined by the PSU manufacturer.
UVP (Under Voltage Protection)| UVP shuts off the PSU when the voltage under the certain stander.
OPP (Over Power Protection)| OPP shuts off the PSU when the power drawn is between 115% ~ 135% of the rated power.
OT (Over Temperature Protection)| OTP makes sure that the PSU will shut down when the internal temperature reaches a set point.
SCP (Short Circuit Protection)| SCP makes sure that the PSU shuts down when the 3.3V, 5V, and 12V rails short to any other rail, or to ground. It also ensures that no damage should occur to the unit, or your PC’s components in the event of a short.

FAQ

  1. Can’t find out the 4 pin CPU cable.
    We provide two 4+4 pin CPU cables, it can be used in split mode.

  2. How to connect 8 pin PCIe with 6+2 pin PCIe cable?
    Combine the 6 pin and 2 pin before connecting it to the GPU.

  3. How to connect the motherboard cable?
    Plug in the 18 pin and 10 pin connectors to the PSU, and insert the 24 pin connector to the motherboard.

  4. Can’t power up the PSU successfully.
    Check if the motherboard and CPU cables are connected to the motherboard exactly, or the PSU will not work.

  5. After installing a new GPU, the PC system crashes frequently.
    It means the PSU is inadequate for your GPU, before purchasing the PSU, please refer to our PSU calculator tool on ENERMAX website.

  6. The fan won’t spin after the PSU power on for a several seconds.
    PSU fan will spin clockwise at the beginning to clean itself and then turn counterclockwise for several seconds, and stop to activate semi-fanless function.

Unit Restricted substances and its chemical symbols
Lead (Pb) Mercury (Hg)
Polybrominated biphenyls (PBB)  Polybrominated diphenyl ethers (PBDE)
case

|

|

|

| ○| ○
wire|

|

|

|

| ○| ○

The main circuit board

|

|

|

|

| ○| ○
電阻

Resistor

|

|

|

|

| ○| ○
Capacitance|

|

|

|

| ○| ○
Diode|

|

|

|

| ○| ○
SMD DIODE|

|

|

|

| ○| ○
IC|

|

|

|

| ○| ○

Transformer /coil

|

|

|

|

| ○| ○
FUSE|

|

|

|

| ○| ○
Heat sink|

|

|

|

| ○| ○

Mylar insulation slices

|

|

|

|

| ○| ○
Switch and socket|

|

|

|

| ○| ○

Fan

|

|

|

|

|

| ○

Plastic parts

|

|

|

|

|

| ○

Packaging materials

|

|

|

|

|

| ○

  • Note 1: “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.

  • Note 2 :“○”indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.

  • Note 3 :The “-” indicates that the restricted substance corresponds to the example on.

  • © 2024, ENERMAX Technology Corporation,

  • 2F-1 , No. 888, Jing-Guo Road, Taoyuan City (330)

  • Tel. +886-3-316-1675,

  • Fax. +886-3-346-6640

  • All rights reserved. Actual product and accessories may differ from Illustrations. Information in this manual is subject to change without prior notice. Printing errors and omissions excepted. All  trademarks, registered trademarks and/or product names mentioned are the property of their respective owners.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals