ORION T6 Rectangular Bolted Top Tank
Product Information
Engineering Specification
Model: ES-OR-T6
Email for Submission:
oriontanks@wattswater.com
Specifications
The Orion T6 tank is a rectangular, seamless, stress and defect-free tank made from rotationally molded construction usingvirgin PE resins conforming to ASTM D 1248. It features a single FIP inlet with dip tube, standard outlet, and vent. All penetrations are heat fused to the tank wall. The non-load bearing tank cover is gasketed and bolted to the top of the tank.
Tank Sizes and Capacities
Capacity (Empty/Effective USG) | Dimensions (L x W x H) | In/Out/Vent Size (In.) |
---|
Connection Locations & Sizes
Select standard or custom inlet, outlet, and vent locations based on your requirements.
Connection, Cover, Support & Access Options
Various connection options are available including optional no hub or flanged connections. Tank anchor flanges, cleanout access, gamma top access, fiberglass wrap, and other accessories can be selected based on your needs.
California Prop 65 Warning
This product contains chemicals known to the State of California to cause cancer and birth defects. For more information, visit www.P65Warnings.ca.gov.
Installation Notes
- Custom C dimension may affect tank capacity.
- Tanks with heights over 18 require external support to prevent bowing of tank walls when filled.
Additional Information
Verify all selections with your local Orion representative as tank products and accessories are non-cancelable and non-returnable.
Product Usage Instructions
Tank Setup
- Choose the appropriate tank size based on capacity requirements.
- Select the connection locations and sizes according to your installation needs.
- Determine any additional accessories required such as cleanout access or tank anchor flanges.
- Ensure proper support is in place for tanks with heights over 18 inches.
Installation
- Thoroughly read all installation instructions provided before beginning the installation process.
- Follow safety information and guidelines during installation to prevent accidents.
- If unsure about any technical details, contact customer service for assistance.
- Verify all selections with your local Orion representative before installing the tank.
Maintenance
- Regularly inspect the tank for any signs of damage or leaks.
- Clean the tank cover and connections periodically to ensure proper functioning.
- If any issues arise, contact customer service for troubleshooting and support.
FAQ
Q: What should I do if I need a custom inlet or outlet location?
A: For custom inlet or outlet locations, indicate the desired locations in the provided diagram and specify the dimensions required. This customization may affect the tank’s effective capacity.
Q: Are extensions available for tanks with heights exceeding standard dimensions?
A: Yes, if the required tank height exceeds the standard height, an extension may be necessary. Please check the extension option and verify the height with Orion Technical Support.
Engineering Specification
Please e-mail your signed and completed submittal, tank quote and purchase order to oriontanks@wattswater.com.
T6 Rectangular Bolted Top Tank
Specification
Orion T6 tank is rectangular, seamless, stress and defect-free, rotationally
molded construction to uniform wall thickness from virgin PE resins conforming
to ASTM D 1248. Single FIP inlet with dip tube, outlet and vent are standard.
All penetrations are heat fused to tank wall. Standard non-load-bearing tank
cover is gasketed and bolted to top of tank.
Call customer service if you need assistance with technical details.
Tank Size
CALIFORNIA PROP 65 WARNING: This product can expose you to chemicals including benzene which is known to the State of California to cause cancer and birth defects or other repro-ductive harm. For more information go to www.P65Warnings.ca.gov.
NOTICE
The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.
Orion Fittings product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Orion Fittings Technical Service. Orion Fittings reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Orion Fittings products previously or subsequently sold.
Connection Locations & Sizes (Select only one locations box)
-
Standard Locations:
Inlet-at 9:00 and centered 4″ down from the top of the tank rim Outlet-at 3:00 and centered 4″ down from the top of the tank rim Vent-at 6:00 & centered 3″ down from top of tank rim -
Custom Locations – C & D Dimensions Required:
Indicate desired locations in the small circles of the top-view diagram below.
I-Inlet O-Outlet V-Vent -
Custom Sizes: Indicate 2″, 3″, 4″, or 6″ in corresponding connection-type box.
Tank Extension
If required tank height exceeds standard height (H) for a buried tank, an
extension may be required. Please check extension option box above. Extension
height will be verified by Orion Technical Support.
Verify all selections with your local Orion rep – tank products and accessory equipment are non-cancelable & non-returnable.
Note:
Rectangular tanks with heights over 18″ require external support (supplied by
others) to prevent bowing out of tank walls when filled.
Allow an extra 2″ on each side of L and W dimensions for cover.
Tanks are made to +0.25 in. tolerance.
USA: T: 800-334-6259 •
OrionFittings.com
Canada: T: 888-208-8927 •
OrionFittings.ca
Latin America: T: (52) 52-4122-0138 •
OrionFittings.com
ES-OR-T6 2422