scs sentinel MVE0100 Motor Drive for Swing Gates Instruction Manual
- July 23, 2024
- SCS sentinel
Table of Contents
- scs sentinel MVE0100 Motor Drive for Swing Gates
- SAFETY INSTRUCTIONS
- INFORMATION
- INSTALLING THE MOTORISED SYSTEM
- Potential risks
- DESCRIPTION
- WIRING/ INSTALLING
- Wiring diagram
- Control box
- SETTING/USING
- System learning process for single leaf gate Switch 1 OFF.
- MAINTENANCE
- Remote control
- TECHNICAL ASSISTANCE
- WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
scs sentinel MVE0100 Motor Drive for Swing Gates
SAFETY INSTRUCTIONS
WARNING: Important safety instructions. It is essential to follow these instructions for reasons of personal ? safety, as incorrect installation may result in serious injury. Keep these instructions in a safe place. If installation is carried out by a third party, this manual must be given to the end user. The end user must also be trained in the safe use of the appliance in accordance with the instructions in this manual.
INFORMATION
SGS SENTINEL certifies that its motorised operators comply with the standards
and safety regulations for motorised gate operators (EN 60335-2-103).
The use of this product outside the specified conditions or the use of
components or accessories not recommended by SGS SENTINEL may compromise the
safety of property and persons, and is therefore prohibited. SGS SENTINEL
accepts no liability for any damage resulting from failure to comply with the
instructions provided in this manual.
BEFORE INSTALLING
This product is only designed for the automation of a swing gate for
“residential” use.
Installation requires qualified staff with mechanical and electrical skills.
Before installing the motorised device, check that the driven part is in good
mechanical condition, properly balanced and opens and closes correctly.
Make sure that the temperature range indicated on the motorised system is
suitable for the installation’s location.
PLEASE NOTE: The motorised system cannot be used with a driven part
incorporating a side gate.
ELECTRICAL INSTALLATION
CAUTION: The power supply installation must comply with current standards
in the country where the prodl.:1..J uct is installed (NF G 15-100 for
France) and be carried out by qualified staff.
The mains supply must be protected against overload by a suitable trip switch
and an earth leakage circuit breaker. A means of disconnecting all the poles
of the power supply network must be provided. This device must be connected
directly to the supply terminals and have a contact separation distance on all
poles to ensure complete disconnection in accordance with the installation
rules.
If the power cable is damaged, it must be replaced by the manufacturer, its
after-sales service or similarly qualified persons in order to avoid a hazard.
INSTALLING THE MOTORISED SYSTEM
CAUTION: The motorised device must be dis connected from its power
source during installation.
WARNING: Make sure that in the installation environment (gate and fixed
parts), the zones at risk are avoided or at least signposted (see “Potential
risks” section after these instructions).
Ensure that crushing caused by the opening movement of the driven part is
avoided between the driven part and the surrounding fixed parts.
WARNING: Activation of the manual disconnection device may cause
uncontrolled movement of the driven part due to mechanical failure or loss of
balance. If a fixed control device is installed (keypad, key selector, etc.),
it must be installed 1.5 m above the ground, away from moving parts but always
within sight of the gate.
If the gate is to operate in automatic closing mode, or if it is to be opened
remotely without a direct view of the gate, photocells must be installed
without fail.
If your gate closes automatically, or if it opens onto the public highway, it
may be compulsory to install a flashing light, depending on the regulations
in the country where the motorised device is installed.
It is the installer’s responsibility to ensure that the installation is
compliant.
After installation, make sure that the mechanism is properly adjusted and that
the protection system and any
manual disconnection devices function properly. Permanently attach the label
concerning the manual disconnection device to the operating element of this
device.
USING THE MOTORISED SYSTEM
PLEASE NOTE: This appliance may be used by children at least 8 years old
and by people with reduced physical, sensory or mental capabilities or
without experience or knowledge, if they are properly supervised or
instructed in the safe use of the appliance, and if the risks involved have
been understood.
Children should not play with the appliance.
The user’s cleaning and maintenance must not be carried out by unsupervised
children.
Do not allow children to play with the unit or its controls. Keep remote
control units out of the reach of children.
WARNING: The user must supervise the gate during operation and keep
people away until the gate is fully opened or closed. Do not deliberately
hinder gate movement.
MAINTENANCE AND UPKEEP OF THE MOTORISED DEVICE
CAUTION: The motorised device must be dis connected from its power
source during cleaning, maintenance and parts replacement.
Check the installation frequently for poor balancing or signs of wear or
damage to cables, springs and mounting. Do not use the appliance if any
repairs or adjustments are required. Only original parts should be used to
replace or repair the motorised system.
For further information, see section
F-Maintenance
REMOTE CONTROLS
CAUTION: Do not swallow the battery (risk of chemical burns).
This product contains a button cell battery. If swallowed, the button cell
battery can cause severe internal burns in only 2 hours and may cause death.
Keep new and used batteries out of the reach of children. If the battery
compartment does not close securely, stop using the product and keep it out
of the reach of children. If you suspect a battery or other part has been
swallowed or inserted into any part of the body, seek medical advice
immediately. Do not clean the remote control with abrasive or corrosive
substances.
Just use a soft cloth. Do not allow children to play with the product or its
packaging. When replacing batteries, ensure they have the same characteristics
as the ones supplied with the product. If the device is not being used for a
prolonged period, remove the batteries unless the system is intended for
emergency situations. Do not expose the batteries to excessive heat or throw
them in a fire.
Potential risks
There are 4 potential risks 3 zones identified opposite:
Risk 1 : Shock and crushing
Prevention :
- Obstacle detection by motor.
- Use of photocells.
Risk 2 : Hand crushing
Prevention :
- Leave a minimum distance of 10 cm between the leaf and the pillar/wall.
- Notch the corner of the pillar without weakening it.
Risk 3 : Imprisonment and crushing
Prevention :
- Obstacle detection by the motor.
- Leave a minimum distance of 50 cm between the motor arm and the wall (or other fixed part).
Risk 4 : Crushing of the feet Prevention :
To avoid a danger zone for feet, leave a minimum distance of 12 cm or a
maximum of 5 mm between the bottom of the leaves and the floor.
DESCRIPTION
Dimensions
WIRING/ INSTALLING
Dimension chart
Comply with the measures shown on the chart for proper installation. Adjust
the gate structure to fit it for best automation, if necessary.
Before proceeding with the installation, be sure that gate moves freely and
that
- Hinges are properly positioned and greased.
- No obstacles in the moving area.
- No frictions between two gate leafs or with the ground while moving
inside opening – installation with closed gate
Outside opening – installing with open gate (max 90°)
Warning ! With outside opening. it is imperative to install a blinker on
pillar for security reasons.
For an external opening, it will be necessary to manufacture a metal part in
order to offset the motors, it is then IMPERATIVE to respect the dimensions of
installation indicated in the table.
Emergency release
In case of power failure or to program your automatic gate, you can manually
unlock the engines:
Under the gate. Insert the hex wrench for unlocking and then turn anti-
clockwise 180 degrees. You can now open the gate by hand.
To lock again the engine, insert the hex wrench for locking and then turn
clockwise 180 degrees.
Permanently attach the label for the manual disconnection device to the operating element of this device.
Motor fixing
Before placing the arm on the gate, unlock the arm (C3) and take out the tub
from the cylinder. Then, retract the tube by 3 cm (this ensures that the gate
is locked when closed).
TIP
If you have problems unlocking your motor, you can use a battery. Simply
connect the white and yellow motor wires, one way or the other following the
polarity to operate the motors.
- Fix the first bracket to the pillar. Position the automation in the bracket, then place the screw and nut.
- Assemble the second bracket with the other side of the automation and screw the bracket to the closed gate.
Make sure arms are fixed in horizontal position especially in those positions:
- Gate in« CLOSE» position
- Gate in« OPEN» position
- Gate at« 45° angle» position
Prior to weld the bracket on the gate leaf (if necessary), cover the gate opener to prevent damages from sparks.
Wiring diagram
Installing
Prepare all the wires of the accessories beforehand and connect the wires to
the gear motors and accessories on the PCB as shown in Figure 1. All of the
wiring connections of the accessories are not requested to distinguish the
positive(+) and the negative(-) polarity.
Control box
BEFORE INSTALLATION
Decide the installation position of control box first, it is suggested to be
installed near the gate and should be protected from possible damage.
Be aware of the motor cable length before deciding the installation position
of the control box.
PRE-INSTALLATION
- Remove the cover by unscrewing the four screws on the cover. See Figure 1 (1 ).
- Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure 1 (2).
- Fix and secure your electronic box on the wall.
- Connect the wires of the various devices to be connected to the PCB board (devices described on the following pages)
- Seal the holes of cables entries
- Close the box by tightening the 4 screws. (See Figure 1 (3))
Motor
MOTOR – WIRE CONNECTION
Avoid tension in the cable during open and close phase.
For gates opened outward:
M1 Motor : Connect the motor wire (Yellow -) to the terminals Mo1 +, and
(White +) to the terminals Mo1-. (motor opening in first)
M2 Motor : Connect the motor wire (Yellow -) to the terminals Mo2 +, and
(White +) to the terminals Mo2 -.
M1 MOTOR CONNECTION (first opening motor)
M2 MOTOR CONNECTION (second opening motor)
Electric Lock (option)
Connect the two wires from the electric lock (24V) to the terminal Lo + and
Lo- on the PCB.
Photocells
The photocells are safety devices for control automatic gates. Consist of one
transmitter and one receiver based in waterproof covers; it is triggered while
breaking the path of the beams. If an obstacle is detected, the gate stops and
opens again slightly allowing the obstacle to be released safely.
Blinker
Remove any packaging before connecting.
SETTING/USING
Single/double gate setting (dip switch 1)
Switch settings: «on» right position, «off» left position.
DIP SWITCH 1 D/S set :
ON = double gate operation
OFF= single gate operation (connection on 11 and 12)
D2- Power setting (dip switch 2 et 3)
Gate auto-close adjustment (dip switch 4)
DIP SWITCH 4
«ON»: Active automatic closing in 30 seconds. Simultaneously pressing the
two remotes top keys (opened or closed gate) will turn OFF the automatic mode
(the blinker will flash 3 times as confirmation). Repeat the operation to turn
ON the automatic mode (the blinker will flash 3 times as confirmation).
Note: in case of automatic closing, photocells are required.
«OFF»: Automatic closing OFF (caution it will still be possible to turn
ON with the remote)
Photocell adjustment (dip switch 5)
DIP SWITCH 5 :
ON : Photocells ON. When the photocells detect an obstacle while the gate
is closing, the gate stops and opens during 2 seconds.
If the gate auto-close is adjusted, and the photocells detect an obstacle when
the gate is totally opened, then the closing time will be reseted.
OFF: No detection by the photocells, the photocells will not control the
opening of the gate.
Dephasing of the leaves (dip switch 6)
DIP SWITCH 6 :
ON : Dephasing in closing/ opening of 8 seconds.
OFF: Dephasing in closing/ opening of 3 seconds.
Decelaration speed
The speed is 70% output of the full speed (no adjustment possible).
LED indication
LED 1 RF indicator : radio frequency
LED1 will be on when remote controls are activated.
LED 2 System learning:
LED 2 blinks twice per second during normal operation and once per second
during learning. Static LED2 means incorrect programming.
LED 3 Photocells:
LED 3 will be on when photocells are not aligned.
LED4 start :
LED 4 will be on if the switch of the transmitter, key selector, or the
push button is activated.
Remote controls learning process
Press “RF-learn” button for 2 seconds, and the LED1 will be on; then press the
transmitter top left button.
The LED1 will blink twice and stay on for 10 seconds then be off. And the
remote memorization has completed.
System learning process for double leaf gate
The remote control memory storing operation must be over before starting the
final system learning process.
Let your gate totally opened then lock them (part C3)
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would), then press the upper-left
key for a double gate.
The system learning process will be as follows, step by step:
After step 6, the system learning process is complete. You can use it with the
remote control:
doble gate full opening pedestrian opealag (Single gate
The LED2 light will remain ON until the system learning process is not over.
Check the wiring connection and repeat the step.
System learning process for single leaf gate Switch 1 OFF.
Open the leaf totally.
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would), then press the upper-
right key for a single gate.
The system learning process will be as follows, step by step:
single gate opening
TECHNICAL FEATURE
Blinker
Remote controls
Photocells
MAINTENANCE
Motor
Conduct the following operations at least every 6 months. If in high intensity
of use, shorten the period in between.
Disconnect the power supply
- Clean and lubricate the screws, the pins, and the hinge with grease.
- Check the fastening points are properly tightened.
- Make the wire connection are in good condition.
Connect the power supply
- Check the power adjustments.
- Check the function of the manual release.
- Check the function of photocells or other safety device.
Remote control
TECHNICAL ASSISTANCE
Troubleshooting
Tutos
Online chat
Any question?
For an individual answer, use our on line chat on our website www.scs-
sentinel.com
WARRANTY
SCS Sentinel grants to this product a longer warranty period, beyond the legal
time, as a sign of quality and reliability.
The invoice will be required as proof of purchase date. Please keep it during
the warranty period.
Carefully keep the barcode and the proof of purchase, that will be necessary
to claim warranty.
Are never covered by our warranty:
- Damage resulting from the consequences of a bad installation (bad wiring, reverse polarity … ).
- Damage resulting from improper use of the device (use in contradiction with the manual) or its modification.
- Damage resulting from the consequences of the use of components not from SCS SENTINEL.
- Damage due to lack of maintenance, physical shock.
- Damage due to weather: hail, lightning, strong wind etc ..
- Returns made without a copy of the invoice or receipt.
WARNINGS
Don’t throw batteries or out of order products with the household waste
(garbage). The dangerous A A substances that they are likely to include may
harm health or the environment. Make your retailer take – back these products
or use the selective collect of garbage proposed by your city.
DECLARATION OF CONFORMITY
SCS Sentinel hereby declares that this product is in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU
and Directive 2006/42/EC. The Declaration of Conformity can be found at:
www.scssentinel.com/downloads
Toutes les infos sure :www.scs-sentinel.com
110, rue Pierre-Gilles de Gennes 49300 Chalet -France
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>