Safety notes

  • In case of the optics breaking, do not use the luminaire and ensure its replacement
  • Important: Do not touch the luminaire during operation or shortly after turning off – the risk of burning! Let the luminaire cool down! – Do not cover, place away from flammable substances
  • Warning: Prevent contact of the luminaire internal parts with water
  • Do not look at the luminaire from a short distance; there is a risk of injury to the eyes
  • Do not disassemble the luminaire – do not adjust or reset the electronic components of the luminaire circuits.
  • Installation and service may only be performed by qualified persons.

LEDtec G2

  • LEDtec G2 100, LEDtec G2 150
  • LEDtec G2 200, LEDtec G2 240

Installation dimensions (mm)

McLED-LEDtec-G2-Industrial-Light-
fig-2

Before you start installation

  • Unpack the product and check it carefully
  • If the product is damaged in any way, submit your claim together with the product in its original packaging Please, do not use the damaged product
  • Do not connect the luminaire to the live mains

Installation

  • Attach the hanging eye to the luminaire. Use a washer, according to Fig. A.
  • Adjust the luminaire to the desired angle in Fig. B.
  • Hang the luminaire on a suitable hinge, according to Fig. C
  • Connect the blue wire to “N”, brown wire to “L” and yellow-green wire to the grounding conductor.
  • If necessary, connect the control according to Fig. D.
  • Check for the correct connection and turn the power on.McLED-LEDtec-G2-Industrial-Light-fig-3

This product contains a light source with an energy efficiency class (see above).

Replaceability:
(1) Light source is not replaceable, the luminaire must be replaced. (2) control gear can be replaced by a qualified electrician without permanently damaging the luminaire.

McLED® warranty

McLED s.r.o. (Ltd.) provides a five-year warranty on LED luminaires
In case of a claim, the customer is entitled to compensation for costs associated with claims only in connection with shipping costs, which shall be approved by the seller in advance. To determine the legitimacy of the claim, the manufacturer must always have the option of assessing the correctness of the LED luminaire installation on the site where it is installed.

Importer: McLED s. r. o. , Vídeňská 185, 252 50 Vestec, tel.: +420 220 184 800, fax: +420 244 910 700, e-mail: office@mcled.cz, www.mcled.cz.