SENSECAP Soil Moisture & Temperature Sensor User Manual

June 7, 2024
SENSECAP

logo

SENSECAP Soil Moisture & Temperature Sensor

product

 Introduction

The S-Soil MT-02 soil moisture & temperature sensor is provided with high accurate and high sensitive. By measuring the dielectric constant of the reaction of soil, soil direct stable real moisture content. This SSOIL MT-02 soil moisture & temperature sensor can measure the volume of soil moisture. the soil moisture measurement method is in line with international standards at present. Apply to the soil moisture monitoring, scientific experiment, water-saving irrigation, greenhouse vegetables, flowers, grass, soil, plant cultivation, measured speed of sewage treatment, grain storage, greenhouse control, precision agriculture, at the same time in the measurement of water, weather and particulate matter content.

Features:
  • High measuring accuracy, fast response, good interchangeability
  • Good sealing performance, corrosion resistance, long buried in soil using
  • The flame retardant epoxy resin curing, completely waterproof, can withstand the strong external shocks
  • Needle using quality materials, can withstand long-term electrolysis, can withstand the corrosion of acid and alkali in the soil
  • High measuring precision, reliable performance, the effects of soil salt content is small, suitable for all kinds of soil
  • Having power reverse protection

Specifications

Soil Temperature

Range| -40 ℃ to +80 ℃
Accuracy| ±0.5℃
Resolution| 0.1 ℃
Soil Moisture
Range| From completely dry to fully saturated (from 0% to 100% of saturation)
Accuracy| ±3% (0~53%); ±5% (53~100%)
Resolution| 1%
General Parameters
Product Model| S-Soil MT-02
Interface| RS-485
Protocol| MODBUS-RTU RS485
Power Supply| 3.6 ~ 30V DC
Current Consumption| Max 40mA @24V DC
Measuring Area| A cylinder area (with the probe as the center, diameter: 7cm, height: 7cm)
Response Time| Less than 1 second
IP Rating| IP68
Cable Length| 5 meters
Operating Temperature| -40 ~ 85℃
Storage Temperature| -40 ~ 85℃
The material of the probe| Food grade stainless steel
Sealing material| The black flame retardant epoxy resin
Installation| All buried or probe into all of the measured medium
Device Weight| 270g

 Wiring

image 1

Yellow RS485+/A/T+
White RS485-/B/T-
Red VCC+, power supply
Black VCC-, power ground
Green SET, V+ (power) when boot module into the “setting mode”. Not connected

or connected with the GND when boot into “mode of operation”.

Module configuration parameters such as Modbus address, baud rate, parity, communication protocol is composed of module inside the EEPROM (power down storage device stores). The specific configuration sometimes forget these parameters that cannot communicate with the module. In order to prevent this problem, the module has a special mode called “mode”. When the module is based on the “mode” electric start, the module communicates with the following parameters:

Fixed Modbus address 0 Communication configuration is 9600, N, 8,1 (9600bps, no parity bit, 8 data bits, a stop bit) Communication protocol for Modbus-RTU

Configuration parameters in EEPROM will not because the module into the

“mode” and “will change, when the module is in communication with in the EEPROM configuration parameter is still running mode”.

Installation

Rapid measurement method: the selected measurement locations, the right to avoid the rocks, to ensure that the needle will not touch the stones like hard object, according to the required depth of cut open the surface soil, maintain the tightness degree of the original soil below the sensor body, clenched vertically inserted into the soil, can not be inserted before and after shaking, ensure the close contact with the soil. A measuring point within a small range test should repeatedly averaging.

Buried in the underground measurement method: vertical drilling diameter greater than 20 cm depth of pit, according to the measurement needs, then the sensor wire inserted into the pit wall in a given level of depth, the pit landfill compaction, ensure the close contact with the soil. Stable after a period of time, can be last for days, months or even longer to measure and record.

If the surface measurement is hard, should first hole (diameter should be less than the diameter of the probe), and then inserted into the soil and the soil compaction and measurement; sensor should prevent violent vibration and impact, but not with a hard object percussion. Because the sensor for black package, in the strong sunlight will make the sensor to make sharp warming (up to over 50 DEG C), in order to prevent the temperature measurement of high temperature impact sensor, please pay attention to sun protection in the field or fields.

Modbus Communication Protocol

  • Serial communication parameters

Modbus is a serial communication protocol, Modicon programmable logic controller (PLC) for the use of published. It has become the industry standard communication protocols, and is now quite common connection between industrial electronic equipment. Modbus has extensive application in the industrial field. Modbus protocol is a master / slave framework agreement. A node is the master node, other nodes using the Modbus protocol in communication from node. Each slave device has a unique address.

Communication parameter default value: baud rate is 9600bps, a start bit, 8 data bits, no parity, one stop bit. Communication protocol for the Modbus RTU protocol. Communication parameters can be set by the program or the Modbus command to change.

  • Modbus Register


Parameter

| ****

Register address (HEX)

| ****


Parameter Type

| Modbus Function

Number

| ****


Range of Parameters and instructions

| ****


default

---|---|---|---|---|---


Channel 0





Temperature

| ****




0x0000

| ****




INT16,read only

| ****




3/4

| -4000-8000

Divided by 100 to obtain the actual temperature value. No temperature measurement model the readout value is always 0.

| ****




no


Volumetric moisture content

| ****


0x0001

| ****


INT16,read only

| ****


3/4

| 0-10000

Water volume is divided by 10000 to obtain the actual rate.

| ****


no

Retain| 0x0002| INT16,read only| 3/4| Always 0| no
Retain| 0x0003| INT16,read only| 3/4| Always 0| no
Volumetric water

content was the original AD value

| ****


0x0004

| ****


INT16,read only

| ****


3/4

| ****

Volumetric water content was the original AD value

| ****


no

Retain| 0x0005| INT16,read only| 3/4| Always 0| no
Retain| 0x0006| INT16,read only| 3/4| Always 0| no
Retain| 0x0007| INT16,read only| 3/4| Always 0| no





Soil Type

| ****




0x0020

| ****




UINT16,read only

| ****




3/6/16

| 0-3


0:Mineral soil (tillage) 1:Sand

2:Clay


3:Organic soil

| ****

0:Mineral soil (tillage)


Modbus Address

| ****

0x0200

| UINT16,Read and write| ****

3/6/16

| ****

0-255

| ****

1









baud rate

| ****








0x0201

| ****







UINT16,Read and write

| ****








3/6/16

| 0-7


0:1200bps 1:2400bps 2:4800bps 3:9600bps 4:19200bps 5:38400bps 6:57600bps

7:115200bps

| ****






3:9600bp


s





protocol

| ****




0x0202

| ****



UINT16,Read and write

| ****




3/6/16

| 0~1


0:Modbus RTU 1:Modbus ASCii

2:ADAM Advantech protocol


3:ADAM Advantech protocol (with parity)

| ****


0:Modbu s RTU



parity

| ****


0x0203

| ****

UINT16,Read and write

| ****


3/6/16

| 0-2

0:No parity 1:Even parity

| 0:No


parity

| | | | 2:Odd parity|
---|---|---|---|---|---


data bits

| ****

0x0204

| UINT16,Read


and write

| ****

3/6/16

| 1


1:8 data bits

| 1:8 data bits



Stop bits

| ****


0x0205

| ****

UINT16,Read


and write

| ****


3/6/16

| 0-1


0:1 stop bits


1:2 stop bits

| 0:1


stop bits





Response delay

| ****




0x0206

| ****



UINT16,Read


and write

| ****




3/6/16

| 0-255

The host request command is received after a delay time and response. The delay time for the set value of *10 Ms. When set to 0 without delay.

| ****




0





active output interval

| ****





0x0207

| ****




UINT16,Read


and write

| ****





3/6/16

| 0-255


Does not need the host request, to automatically send data fixed time interval. The time interval for the setting value * 1. Set to prohibit active output

function 0.

| ****





0

Note : UINT16:16 bit unsigned integer register INT16:16 bit signed integer register UINT32:32 bit unsigned integer register UINT32:32 bit signed integer register BIT: bit register

  • Detail of Modbus Register

Soil Temperature

parameter range| -4000-8000| Default: none
parameter storage| none|
Significance: the measured value of the temperature, negative for complement representation.


Example: if the return value is 0702H (16 m, the original code), the first byte byte second byte 07H, low byte is 02H, then the temperature measurement value of (07H*256+02H) /100=17.94 C.

If the return value is FF05H (16 m, complement), the first byte byte second byte FFH, low byte is 05H, then the temperature measurement value ((FFH*256+05H) -FFFFH-1H) /100 = (FF05H-FFFFH-1H)

/100=-2.51 C.

Soil Volumetric Water Content

parameter range| 0-5000| Default: none
parameter storage| none|
Significance: volumetric water content measurements. ****

Example: if the return value is 071DH (16 m), the first byte byte second byte 07H, low byte is 1DH, then the volumetric water content was measured (07H256+1DH) /10000= (7256+29) /10000=18.21%.

Volumetric Water Content Raw AD

parameter range| Not fixed| Default: none
parameter storage| none|
Significance: volumetric water content was the original AD value.

*** Example: if the return value is 071DH (16 m), the first byte byte second byte 07H, low byte is 1DH, then the volumetric water content was the original AD value was (07H256+1DH) = (7*256+29) =1821.

Soil Type

parameter range| 0-3| Default: none
parameter storage| Immediate memory|
Significance: soil type.

0: mineral soil (tillage soil)

1: sand

2: clay

3: organic soil

Example: if the return value is 071DH (16 m), the first byte byte second byte 07H, low byte is 1DH, then the volumetric water content was the original AD value was (07H256+1DH) = (7256+29) =1821.

Modbus Address

parameter range| 0-255| Default:1
parameter storage| Immediate memory|
The Modbus address, can be set to 0-255. When the module external address code switch is set to address 0, use this register contents as the slave address. After setting the need to power on or use the RST command to restart module, make this address in force. Use this command to modify the module address does not need to open the cabinet can be set.

Baud Rate

parameter range| 0-7

0:1200bps

1:2400bps

2:4800bps

3:9600bps

4:19200bps

5:38400bps

6:57600bps

7:115200bps

| Default:3
parameter storage| Immediate memory|

Protocol

parameter range| 0~1

0:Modbus RTU 1:Modbus ASCII

| Default:0
parameter storage| Immediate memory|

Parity

parameter range| 0-2

0:No parity 1:Even parity 2:Odd parity

| Default:0
parameter storage| Immediate memory|

Data Bits

parameter range| 1

1:8 data bits

| Default: 1, only supports 8 bits of data, the other is

invalid

parameter storage| Immediate memory|
Stop bits
parameter range| 0-1

0:1 stop bits

1:2 stop bits

| Default:0
parameter storage| Immediate memory|

Response Delay

parameter range| 0-255| Default:0
parameter storage| Immediate memory|
Serial communication delay in response to a user in the following cases: when the host sends a request command module, delay (RESPONSEDELAY10) ms, then the response data is returned to the host computer. For example, set the RESPONSEDELAY=5, then the module delay 510=50 ms after the response of host requests. When set to 0 for no delay immediate response. This command is mainly applied to the host from the sending State RS485 switch to slow the receiving state occasions.

Active Output Interval

parameter range| 0-255| Default:0
parameter storage| Immediate memory|
Serial communication active output time interval used in the following cases: the host does not need to send a request command, module active output response data, output interval for ACTIVEOUTPUTINTERVAL seconds, such as setting the ACTIVEOUTPUTINTERVAL=5 module, then every 5 seconds according to the communication protocol of the output data set. When set to 0 active output invalid, need a host requests before response. This command is mainly used in GPRS wireless transmission, need to terminal nodes initiatively sends data occasions. Note: when set to the active output data, RS485 bus can connect a module, in order to avoid data conflict.

CRC16 Validation and Sample Code

For example: 0x0000H-0x0001H read registers, measuring temperature, volumetric water content value
Request: 01 03 00 00 00 02 C4 0B (8 bytes)

Device address 1 byte 0x01
Function number 2 bytes 0x03
starting register address

2 bytes

|

0x0000

number of registers|

2 bytes

|

0x0002

Check| 2 bytes| 0xC40B

Request : 01 03 04 07 02 07 1D E1 7E (9 bytes)

Device address 1 byte 0x01
Function number 1 byte 0x03
effective number of bytes

1 byte

|

0x04

Data| 4 bytes| 0x07 (high temperature byte)
| | 0x02 (low temperature byte)
| | 0x07 (high volume water content byte)
| | 0x1D (low volume water content byte)
check| 2 bytes| 0xE17E

When the 9 bytes of data receiving equipment return, the following CRC computations, where num
(parameter 2) = 9.

// __

//CRC calculation of C51 language function is as follows

/ / input parameters of 1:snd, to check the byte array name

/ / input parameters of 2:num, the total number of bytes to be calibrated. (2 bytes including CRC check)

/ / function return value: return a value other than 0 check failed. Check back 0.

// __ unsigned int calc_crc16 (unsigned char *snd, unsigned char num)

{

unsigned char i,  j;

unsigned int c,crc=0xFFFF;

for(i = 0; i < num; i ++)

{

c = snd[i] & 0x00FF;

crc ^= c;

for(j = 0;j < 8; j ++)

{

if (crc & 0x0001)

{

crc>>=1; crc^=0xA001;

}

else

{

crc>>=1;

}

}

}

return(crc);

}

To get results back to 0 then the verification is successful, if the validation fails to return to a non-zero value.
After the successful calibration, use the following formula to calculate the temperature and volumetric moisture content (negative to complement representation):
When the temperature = (07H256+02H) /100=17.94
The volumetric moisture content = (07H
256+1DH) /10000= (7*256+29) /10000=18.21%
If the check fails, the error transfer process, should abandon the collected data, re collection.logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals