SX1302-US915 M2 Multi-Platform Gateway and SenseCAP Sensors Instruction Manual

June 12, 2024
SENSECAP

SX1302-US915 M2 Multi-Platform Gateway and SenseCAP Sensors

Product Information

The SenseCAP is a multi-platform gateway and sensor system that allows users to monitor and collect data from various environmentalsensors. The system consists of the SenseCAP M2 Multi-Platform Gateway and SenseCAP Sensors. It provides a convenient and efficient solution for environmental data collection and analysis.

Product Usage Instructions

Gateway Network Configuration
To configure the network settings of the SenseCAP M2 Multi-Platform Gateway, follow these steps:

Connect to Ethernet Cable

  1. Connect the antenna and power adaptor to the gateway.
  2. The power LED will show in red.
  3. Wait for about 15 seconds for the indicator on the top to flash green, indicating that the gateway is booting.
  4. Connect the Ethernet cable to the Ethernet port.
  5. The indicator on the top will show solid green if the gateway is successfully connected to the internet.

Connect to WIFI via Luci
To connect to WIFI using Luci, you have two options:

Access via router

  1. Connect your device to an Ethernet cable and connect your PC to the same router.
  2. Check the IP Address of your device on your router admin page.
  3. Find the Username and Password on your device label.
  4. In your browser, enter the IP Address of your device to access the Luci page.
  5. Enter your device username and password to login.

Access via device AP hotspot

  1. Turn on the device AP hotspot by pressing the button for 5 seconds until the blue indicator flashes slowly.
  2. Connect your computer to the AP hotspot named SenseCAP_XXXXXX (6-figure MAC address). The default password is 12345678.
  3. Find the Username and Password on your device label.
  4. In your browser, enter the IP Address (192.168.168.1) to access the Local Console.
  5. Enter your device username and password, and click the Login button.

Connect to a WIFI

  1. Click on Network – Wireless.
  2. Click on the Scan button to scan for available WIFI networks.
  3. Select your WIFI network to join.
  4. Submit the Wi-Fi password and click Submit and Save.
  5. Click Save and Apply to apply your settings.
  6. The indicator on the top will show solid green if the gateway is successfully connected to the WIFI.

Connect with Cellular (for 4G version)

  1. Plug your SIM card into the Nano-SIM card slot.
  2. Login to the Luci page and click on Network – Cellular.
  3. Setup the APN info and click Save and Apply to apply your settings.

POE connection
The SenseCAP M2 Multi-Platform Gateway supports PoE (Power over Ethernet) and is compatible with the IEEE 802.3af standard.

Gateway Network Configuration

Connect the antenna and power adaptor to the gateway.
The power LED will show in red, and in about 15s, the indicator on the top will flash green, indicating that the gateway is booting.

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(1\)

There are two ways to connect to the Internet. Choose the one that works for you.

Connect to Ethernet Cable
Connect the Ethernet cable to the Ethernet port, and the indicator on the top will show solid green if the gateway is successfully connected to the internet.

Connect to WIFI via Luci
There are two ways for users to login Luci configuration page.

Access via router

  • Step 1: Connect your device to a Ethernet cable, and connect your PC to the same router.
    Note: Your PC and device should be connected to the same router/network.

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(2\)

  • Step 2: Get IP Address of your device
    Check the IP Address of your device on your router admin page.

  • Step 3: Get your device Username and Password
    You can find the Username and Password on your device label.

  • Step 4: Login Luci

  • Input the IP Address of your device in a browser to enter the Luci page. Then input your device username and password to login.

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(4\)

Access via device AP hotspot

  • Step 1: Turn on the device AP hotspot.
    Press the button for 5s until the blue indicator flashes slowly to enter the configuration mode.

  • Step 2: Connect to the AP hotspot.
    AP hotspot name is SenseCAP_XXXXXX (6-figure MAC address),default password is 12345678; connect your computer to this AP hotspot.

  • Step 3: Get your device
    Username and Password You can find the Username and Password on your device label.

  • Step 4: Log in to the Local Console
    Input the IP Address (192.168.168.1) in your browser to enter the Local Console. Then input your device username and password, and click the Login button.

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(7\)

Connect to a WIFI
Click on Network – Wireless

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(8\)

Click on the Scan button to scan the WIFI

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(9\)

Select your WI-FI to join the network.

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(10\)

Submit the Wi-Fi password, and then click Submit and Save.

Then click Save and Apply to apply your settings.
The indicator on the top will show solid green if the gateway is successfully connected to the WIFI.

Connect with Cellular(for 4G version)

  • Step 1: Plug your SIM card into the Nano-SIM card slot
    SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(12\)

  • Step 2: Login the Luci page, and click on Network – Cellular’
    SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(13\)

  • Step 3: Setup the APN info, and click Save and Apply to apply your settings.
    SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(14\)

POE connection
SenseCAP M2 supports PoE (Power on Ethernet) and is compatiblewith IEEE 802.3 af standard. Note:
You will need to have an extra PoE switch that provides 40V-57V DCpower asa PSE (Power Sourcing Equipment) if your modem/router does not support PoE.

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(15\)

Checking the Gateway Connection Status After powering on the gateway, there are two ways for you to check the gateway working status::

LED Indicator


Mode

| ****

Description

---|---
Green| Solid| Gateway is healthy and the internet is well connected.
Slow blinking| Gateway is booting, please wait.
Blue| Solid| The gateway is ready for internet connection. Further configuration is needed.
Slow blinking| Configuration mode, and will auto exit after 5 mins if no activity.
Fast blinking| Press the button for 3 0 s until the indicator show fast flash will trigger the factory reset.


Orange

| Slow blinking| Firmware is updating, and please do not power off the gateway or disconnect the internet.
**** White| Solid| Gateway is only with a factory firmware, and will be updated to the latest firmware automatically when it is connected to the internet.


**** Red

| Solid| Hardware issue or internet connection failure.
Slow blinking| Gateway not connected to the LNS.

SenseCAP Mate APP
In the SenseCAP Mate App, “Online status” indicates “Online” when the gateway is connected to the network and can receive and transfer  sensor data. Please refer to the next chapter for obtaining the SenseCAP App.

Bind the gateway

SenseCAP Mate APP supports device configuration and remote
management.

  • Step 1: Download the SenseCAP Mate APP
    SenseCAP Mate APP for iOS on App Store
    SenseCAP Mate APP for Android on the Google Play Store
    You can also download App from App Center
    SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(16\)

  • Step 2: Login the APP
    If it is your first time to use the SenseCAP platform, please register an account first.
    Note: Please select Global of Server Location

  • Step 3: Add device
    Click the + in the upper right corner and select Add device
    Then scan the QR code on your gateway label.

Set up your device name and location. Then confirm your settings. After successful binding, you will see your gateway in the Device directory.
SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(17\)

Connect the SenseCAP Sensors

  • Step 1: Add device
    Click the + in the upper right corner and select Add device
    Then scan the QR code on your gateway label.

  • Step 2: Select the frequency plan
    Click on “Settings”, set the platform and frequency, the frequency should match your gateway frequency. eg: If your gateway is US915 version , then you need to set your sensor toUS915 frequency.
    Note: Sense CAP M2 Multi-Platform Gateway can’t connect to Helium network.
    For more configurations about Sense CAP sensors, please refer to: Sense CAP Sensor

SenseCAP Portal and Mate APP

SenseCAP Mate APP and SenseCAP Portal can be used to check your device status and device management.

  • SenseCAP Mate APP for iOS on App Store
  • SenseCAP Mate APP for Android on the Google Play Store
  • SenseCAP Portal

Gateway Info
Check the gateway info on the SenseCAP Portal and SenseCAP MateAPP

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(5\)

Sensor data
Check the sensor data on the SenseCAP Portal and SenseCAP Mate APP

SX1302-US915-M2-Multi-Platform-Gateway-and-SenseCAP-Sensors-FIG-
\(6\)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals