SoClean Device Disinfector User Manual
- June 7, 2024
- SoClean
Table of Contents
- OVERVIEW
- SPECIFICATIONS
- OZONE INFORMATION
- FCC NOTICE PART
- Warnings and Precautions
- Warranty Information
- PARTS, BUTTONS & ICONS
- SETTING UP YOUR SOCLEAN DEVICE DISINFECTOR
- USING YOUR SOCLEAN DEVICE DISINFECTOR
- Maintenance
- REORDERING PARTS OR ACCESSORIES
- General Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SoClean Device Disinfector User Manual
OVERVIEW
SYMBOLS
-
Consult Manual
-
Do not use if package is damaged.
-
Not made with natural rubber latex
-
Serial Number
-
Waste Electrical and Electronic Equipment (WEEE). It is the responsibility of the end user to dispose of this equipment at a designated collection point
-
Operating Conditions
-
No Liquid in Chamber
-
Date of Manufacture
-
General Caution or Warning
-
Federal Communication
DISPOSAL INFORMATION Safe Disposal of the device: Follow the local, state, and national governing ordinances and recycling instructions regarding disposal or recycling of the device and device components at the end of the expected service life.
SPECIFICATIONS
Operating Conditions
10°C to 38°C (50°F to 100°F)
15% to 75% humidity
Physical Characteristics
Dimensions: 7.875” x 7.25” x 8.875”,
200 mm x 184 mm x 225 mm
Weight: 5.6 lbs, 2.5 kg
Cord Length: 4’ 8”, 1422.4 mm
Ozone Concentration
180ppm maximum from ozone generator
Electrical Characteristics
Use with power supply unit:
Model UES 18LCP-120150SPA
AC Adapter Output: DC 12V, 1.5A Max
Power Consumption: 18W Max
Storage and Transport Conditions
-20°C to +55°C (-4°F to 131°F)
15% to 95% non-condensing humidity
USB
USB output: 5V, 1A
OZONE INFORMATION
Ozone is a gaseous disinfectant that breaks down to oxygen after it is
generated. The SoClean Device Disinfector has a Filter inside the Chamber to
convert ozone back to oxygen and is designed to contain ozone within the
system, contacting the items only, not the user, during the Cycle.
The smell of ozone is detectable at low concentrations by some people and you
may smell ozone briefly during the Cycle. The scent of ozone has the
characteristic of a sweet chlorine-like smell.
WARNING: Discontinue use if strong ozone odor is detected or, in rare cases, if those with respiratory sensitivities experience irritation.
FCC NOTICE PART
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving
- Increase the separation between the equipment and
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
Consult SoClean Customer Care for help
FCC Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Caution: This equipment complies with FCC/IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. To maintain compliance with the FCC and IC RF Exposure guidelines, place the unit at least 20 cm away from nearby persons.
Warnings and Precautions
WARNING: Discontinue use if strong ozone odor is detected or, in rare cases, if those with respiratory sensitivities experience irritation.
CAUTION: Do not submerge the SoClean Device Disinfector in water or use chemical cleaners on or in your SoClean Device Disinfector. Keep away from water sources including rain, bathtubs, sinks, and pools.
WARNING: Do not place any living thing inside the Device Chamber.
WARNING: Do not place any flammable or ignitable items on top of the SoClean Device Disinfector. Do not use in explosive air environments, near gas vapors, or other flammables, etc.
CAUTION: Ensure that the SoClean Device Disinfector Lid Gasket is not damaged by inspecting for visible cracks before operating a Cycle.
WARNING : Do not disassemble the SoClean Device Disinfector.
WARNING: The appliance is only to be used with the power supply unit provided with the appliance.
WARNING: This appliance is intended to be household and indoor used only.
CAUTION: Do not clean your items with fragrant soap prior to device use.
CAUTION: If the SoClean Device Disinfector has been dropped or visibly damaged or if cracks in the enclosure are noticed, stop usage and contact SoClean.
CAUTION: In the event of loss of power, rerun the
Cycle.
NOTE TO USERS : Any serious incident that has occurred in relation to the
device should be reported to SoClean.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
Warranty Information
WARRANTY FOR SOCLEAN DEVICE DISINFECTOR
**** SoClean Inc. warrants this product under this warranty for a two
(2) year limited warranty for defects in manufacture or workmanship. For all
warranty issues, a Return Authorization Number and Proof of Purchase is
required. Please contact SoClean at
info@soclean.com or
866-501-3705 for a Return Authorization
Number. CODs are not accepted. Shipping fees are non-refundable
Products repaired or replaced under this warranty will not incur
reshipping charges. Under this warranty, the sole remedy shall be repair or
replacement at SoClean’s discretion.
This warranty does not cover product failures due to misuse, abuse,
improper maintenance, normal wear and tear, typical required periodic
replacement products, or circumstances beyond the control of SoClean.
IMPORTANT: Please purchase your Filter from SoClean to ensure authenticity. For purchases from an online marketplace such as Amazon®, please check “sold by SoClean” before making your purchase. Your SoClean Device Disinfector has been designed to only work with genuine SoClean Device Disinfector Filters. You will not be able to operate your SoClean system with an inauthentic SoClean Device Disinfector Filter. Warranties will be voided if the product is used with an inauthentic Filter and not replaced in accordance with usage instructions.
LIMITATION DAMAGES: SOCLEAN SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. NO LIABILITY ARISING FROM ITS USE, HOWEVER, CAN BE ACCEPTED BY THE COMPANY, WHO RESERVES THE RIGHT, WITHOUT PRIOR NOTICE, TO ALTER THE SPECIFICATIONS, CONSTRUCTION, OR CONTENT OF ITS EQUIPMENT AT THE COMPANY’S OWN DISCRETION.
PARTS, BUTTONS & ICONS
LID GASKET: Seals the Lid in order to contain ozone within the Chamber.
CAUTION: Ensure that the SoClean Device Disinfector Lid
Gasket is not damaged by inspecting for visible cracks before operating a
Cycle.
LID LATCH: Keeps the Lid of the device closed securely during the Cycle.
CHAMBER: Place your items inside the Chamber during a Cycle. Be careful
not to overfill or force Lid closed.
CONTROLPANEL: Houses all the buttons and icons for operating your SoClean Device Disinfector
LID: Opens for access to the Chamber
NOTE: The SoClean Device Disinfector Lid will not open during a Cycle
until the Cycle Complete Icon illuminates green.
**FILTER:
** Converts ozone in the Chamber into oxygen. Your device will remind you when the Filter needs to be replaced.
FILTER DOOR:
Your Filter goes in here. The device will not operate a Cycle if the Door
is open, or if the Filter is inauthentic or missing.
AIR INLET:
Air enters the device from this small hole and is converted into ozone
during the Cycle.
POWER INPUT:
The Power Supply provided plugs in here.
PHONE CHARGING PORT:
There is a USB port on the back for convenient charging of another device.
Do not attempt to charge a device that is in the Chamber.
WARNING : Do not disassemble the SoClean Device Disinfector.
CYCLE START:
Initiates the Cycle with a single push.
CYCLE LENGTH:
Used to set a 5, 10 or 20 minute Cycle Length. The default Cycle Length is
set to 20 minutes. You can select a length by pushing once for 5 minutes,
twice for 10 minutes and three times for 20 minutes.
LIDOPEN:
Opens the Lid when the device is powered. This button can also be used to
cancel an active Cycle by pushing and holding for 5 seconds.
NOTE: If you cancel a Cycle, the Lid cannot be opened until Cycle
Complete Icon illuminates green.
NOTE:
There is no power button. The device is powered and “on” when it is plugged
in.
CAUTION: In the event of loss of power, rerun the Cycle.
SYSTEM
Solid Red
Indicates when your device has detected an issue that prevents it from
operating a Cycle. Contact customer care for assistance.
Flashing Red
Indicates that the Lid cannot be opened because a Cycle is in process. See
step 4 on page 15 for Canceling a Cycle.
CYCLE COMPLETE
Solid Green Indicates that a Cycle is complete.
5, 10 OR 20 MINUTE CYCLE LENGTH
Solid Blue Indicates if a Cycle Length has been programmed.
FILTER ISSUE:
Flashing Amber Indicates that it is time to order a new Filter.
NOTE: You can still use your device during this time
Solid Amber
Indicates that your Filter has expired and will need to be replaced. You will
not be able to operate a Cycle.
FILTER DOOR ISSUE
Solid Amber Indicates that the Filter Door is not completely closed. Check
your Filter Door and open/ close it securely
CYCLE PROGRESS BAR
Progressive Blue: Gradually turns blue from the left to the rightas an
indication of the progress of a Cycle.
Solid Red
Indicates that an active Cycle has been interrupted (example: temporary loss
of power).
NOTE: During this time, your device is pumping air through the system to
remove ozone.
SETTING UP YOUR SOCLEAN DEVICE DISINFECTOR
-
Plug one end of the Power Adapter cord into the back of
the device and the other end into AC wall outlet.
-
Unpack and install the Filter into the back of the device. Ensure that the blue rubber gasket on the Filter is facing the Chamber.
USING YOUR SOCLEAN DEVICE DISINFECTOR
-
Open the Lid by pressing the Lid Open button.
NOTE: The SoClean Device Disinfector Lid will not open during a Cycle until the Cycle Complete Icon illuminates green. -
Organize your items inside the device Chamber and close the Lid. Do not to stack your items in the Chamber. The ozone needs room to flow around the items. Do not block the ozone port.
-
Run a Cycle by first selecting your desired Cycle Length then pushing the Cycle Start button. The default Cycle Length is set to 20 minutes.
WARNING: Discontinue use if strong ozone odor is detected or, in rare cases, if those with respiratory sensitivities experience irritation.
- When the Cycle Complete icon lights up green you can now push the Lid Open Button and remove your items. NOTE: You can cancel a Cycle at any time. Simply press and hold the Lid Open button for 5 seconds. The cancellation will not happen immediately. The system needs time to purge the ozone from the Chamber. During this time, the System icon will flash red indicating the Lid is locked and the Cycle Start button will illuminate blue. The Progress Bar on the Control Panel will flash blue while the cycle cancellation is in progress. The Cycle Complete Icon will light up green when you can open the Lid to remove your items.
Maintenance
CLEANING YOUR DEVICE
To clean, wipe the interior and exterior of your device with a slightly damp cloth. Do not submerge the device in liquid or use chemical cleaners. Do not put water inside the device Chamber.
CAUTION:
Do not submerge the SoClean Device Disinfector in water or use
chemical cleaners on or in your SoClean Device Disinfector. Keep away from
water sources including rain, bathtubs, sinks, and pools.
WASHING YOUR ITEMS
To pre-clean dirt or oil, use fragrance-free wipes or soap on your high-touch
items before dropping them into the SoClean Device Disinfector.
CAUTION: Do not clean your items with fragrant soap prior
to device use.
VISIBLE CRACKS OR DAMAGE
CAUTION: If the SoClean Device Disinfector has been dropped or visibly damaged or if cracks in the enclosure are noticed, stop usage and contact SoClean.
REPLACING THE FILTER
The advanced technology in our Filter quickly converts the ozone, into fresh
oxygen as it exhausts from the unit. No need to mark your calendar, your
device will remind you! Filter must be replaced approximately every 6 months
with one Cycle run per day. The Filter Issue icon will flash amber to
remind you to change your Filter.
REORDERING PARTS OR ACCESSORIES
To reorder supplies, contact your authorized reseller or visit SoClean. com/device.
IMPORTANT: For extended product life, use only authentic parts. Please purchase your Filters from SoClean to ensure authenticity. For purchases from an online marketplace such as Amazon® or eBay® please check “sold by” SoClean before making your purchase. Authentic SoClean Filters contain unique technology required for use of the SoClean Device Disinfector. The manufacturer is not responsible for device malfunction or accidents caused by the use of inauthentic parts or accessories. Please contact SoClean immediately if you have had any issues with your Filter.
Your SoClean Device Disinfector has been designed to only work with authentic Filters. You will not be able to operate your SoClean Device Disinfector with an inauthentic Filter.
Part name | SKU | Description |
---|
Filter
|
PN1507
|
The Filter converts ozone in the Chamber to oxygen after the Cycle has run.
The Filter needs to be replaced approximately every 6 months with one Cycle run per day. The device reminds you when the Filter needs replacement.
AC Power Adapter|
PN1422
|
Used to power your SoClean Device Disinfector.
General Troubleshooting
PROBLEM | YOU SEE | POSSIBLE CAUSES |
---|---|---|
Device will operate a Cycle but needs a replacement part soon | This icon is | |
flashing amber on the Control Panel | Time to order new filter. | |
Your device will not operate a Cycle | This icon is solid amber on the Control | |
Panel | The Filter door may be open. | |
This icon | ||
is solid amber on the Control Panel | The Filter is expired. |
This icon is
solid red on the Control Panel| There may be an internal device issue.
None of the lights illuminate, even when I push buttons| The device may not be
powered.
SOLUTIONS
- Order replacement Filter
- Open and securely close the Filter door.
- Replace with a new Filter
- Unplug your device from its power source and plug it back in. If the issue persists, contact SoClean customer service.
- Check that the AC power cord is plugged-in correctly into the back of the device and the AC wall outlet. Your device will not operate a Cycle
PROBLEM| YOU SEE|
---|---|---
Your device will not operate a Cycle| | Progress bar is flashing blue.
Lid does not open when the Lid Open button is pushed| | These icons are illuminated
blue on the Control Panel.
The “!” icon will flash after the Lid Open button is pushed.
| | I
hear a click and the buttons light up blue but the Lid doesn’t open.
Your device is making a noise like it’s operating but there are several red
indicators on the control panel| | These icons are illuminated on the
Control Panel.
POSSIBLE CAUSES| SOLUTIONS
---|---
Indicates the Cycle has been canceled.| The Progress Bar on the Control Panel
will flash blue until the cycle cancellation progress is complete.
The Cycle is running.| The Lid is locked during a Cycle. To cancel the cycle,
press the Lid Open button for approximately 5 seconds. The cancellation will
not happen immediately. The system needs time to purge the ozone from the
Chamber. The Cycle Complete icon will illuminate green signaling that the Lid
can now be opened.
The Lid may be stuck.| Be sure to release the button once you hear the click.
Your device was operating a Cycle and one of the following occurred:
- Power to the device was momentarily lost
- Lid was forced opened
- Internal device Issue
| Your device is pumping air through the system to remove ozone and allow you to access your items. Allow this Cycle to complete. You can then either remove your items for use or start a new Cycle.
PROBLEM | YOU SEE | POSSIBLE CAUSES |
---|---|---|
Strong scent of ozone during Cycle | Your device appears to operate normally. |
There may be physical damage to your device.
My item is discoloring or getting sticky| Your device appears to operate
normally.| Material in your item may be incompatible with ozone.
SOLUTIONS:
- Disconnect the power, step away from the device and contact SoClean.
- Discontinue use and contact SoClean customer service.
Thank you for purchasing SoClean Device Disinfector
The SoClean Device Disinfector kills germs
on the surfaces of your common high-touch
items when used in accordance with its labeled
directions for use.*† This manual contains the information you need
to get your SoClean Device Disinfector up and
running. Please read this entire manual carefully
before using your SoClean Device Disinfector and
keep it for future reference.
For questions regarding setup or operation, contact
us by visiting SoClean.com/device-user-manual
or call 866-501-3705
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>