soclean PAP Disinfecting Device User Guide
- June 5, 2024
- SoClean
Table of Contents
- soclean PAP Disinfecting Device
- Indication of Use, Cautions, and Specifications
- Included with your SoClean
- Important Supplies
- Understanding Your PAP Machine
- Your SoClean Timer & Display
- Using Your SoClean
- Care and Maintenance for your SoClean
- FAQ
- Classification, Symbols, FCC Notice
- FCC NOTICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
soclean PAP Disinfecting Device
Thank You!
Thank you for your purchase of the SoClean 2 PAP disinfecting system.
Please familiarize yourself with this manual and the operation of the unit.
After a few simple steps, you’ll find that daily disinfecting of your PAP
equipment has never been easier. The SoClean disinfecting process eliminates
bacteria, mold, viruses and other pathogens, without the need for water or
messy liquid chemicals.SoClean is committed to developing innovative and safe
ways to improve the health and well-being of PAP users. Please feel free to
contact us with any questions you may have at
www.SoClean.com.
Indication of Use, Cautions, and Specifications
-
Indications for Use: The SoClean is a general Positive Airway Pressure (PAP) disinfecting unit
and is intended to be used in the home. A individual who uses Positive Airway Pressure (PAP) for Obstructive Sleep Apnea (OSA) treatment can use the SoClean to disinfect his or her PAP equipment when the daily cleaning procedures are not followed or when the user wants the added benefit of thorough PAP equipment disinfection. -
The SoClean is designed to be attached to a user’s PAP machine continuously, while only running when the mask is inside the disinfecting chamber.
-
Contraindications for Use: Do not use SoClean if a fragrant essence is used in the PAP water reservoir or if highly fragrant detergents are used to clean the PAP equipment. Discontinue use if acne or rash develops along mask contact line.
- DANGER: Keep away from water sources including rain, bathtubs, sinks and pools.
- DANGER: Keep away from children. It is not a toy!
- DANGER: Do not use in explosive air environments, near gas vapors, or other flammables, etc.
- DANGER: Do not place any items on top of SoClean Unit, particularly flammables or ignitable items.
- DANGER: Never place any living thing inside.
- WARNING: Do not dismantle the SoClean unit.
- WARNING: Do not run the SoClean for more than 30 minutes consecutively.
- WARNING: Please be aware that there are sensitive electronics inside the SoClean. If you need to clean your SoClean, wipe with a damp cloth. Do not submerge your SoClean or use any chemical cleaners to clean out the inside of the SoClean chamber.
-
Electrical Characteristics
Adapter input: AC 100~240V, 50/60HZ
Adapter output: DC 12V, 1.5A Max Power Consumption: 18W Max -
Environmental Characteristics Operating: 50F to 100F, 15% to 70% humidity Storage: -4F to 131F, 15% to 70% humidity
-
Physical Characteristics Dimensions: 7.875” x 7.25” x 8.875” Weight: 5.6lbs Cord Length: 4’ 8”
Included with your SoClean
Important Supplies
-
Check Valve (installed)
Prevents water in your humidifier reservoir from backing up into your SoClean machine. If you can see water in the clear tube, replace the check valve assembly immediately. Replace every 6 months, or when the SoClean display shows the “Order Filter Kit” message. -
Filter Cartridge (installed)
This filter converts activated oxygen back into normal oxygen.
Replace every 6 months, or when the SoClean display shows the “Order Filter Kit” message. -
Neutralizing Pre-Wash
Fragrance-free hypoallergenic cleaning solution. The pre-wash neutralizes any pre-existing odors from detergents, and removes any residue from the manufacturing process that could react with activated oxygen. Use the pre-wash whenever you hand wash your PAP equipment. Alternatively, you may use any other fragrance-free, dye-free dish soap.
Understanding Your PAP Machine
The SoClean is designed to connect to your PAP machine. This manual references some of the individual components of your PAP machine. Please use the diagram below to familiarize yourself with these terms before proceeding. Please note that there are many types of PAP machines. This diagram is for example reference only
-
Pre-washing your PAP Equipment
Use two capfuls of the included pre-wash with a gallon of water to wash your PAP equipment (mask, hose, and reservoir), then rinse thoroughly with clean water.
Note: The SoClean 2 uses no fluids in its operation. The pre-wash is supplied for hand washing your PAP equipment only. DO NOT immerse your SoClean in water. -
Installing the Injection Fitting
The injection fitting connects the SoClean to your PAP machine. Once installed, you do not need to disconnect the injection fitting to use your PAP. You may leave the SoClean connected to your PAP. If you need instructions for connecting to your specific PAP model, please visit our website www.SoClean.com.
With humidifier : Disconnect your PAP hose from your PAP machine. Position the injection fitting onto the port of your humidifier, allowing the smaller tubing to enter into the reservoir. The end of the tubing should rest on or near the bottom of the reservoir, over the heat plate. If necessary, carefully trim the injection tubing in increments until it is the correct length.
Now connect your PAP hose to the end of the injection fitting.
You may operate the SoClean with or without water in the humidifier reservoir.
The SoClean will disinfect any water in the humidifier reservoir as long as
the end of the injection tubing rests on or near the bottom of the reservoir,
and below water level.
Note: Different reservoirs may require different approaches to hose insertion. If you have difficulty, visit www.SoClean.com for information on various humidifier models, or contact SoClean directly at 1(866) 501-3705.
Without humidifier: If you are currently not using a humidifier, remove
the short length of black tubing from the inside of the injection fitting by
pulling it straight off, and then attach the fitting directly to your PAP
machine. Reconnect your PAP hose to the end of the injection fitting.
Depending on the style of your reservoir, you may need to disconnect the
fitting to add water to your reservoir.
If you regularly use your PAP without the reservoir attached, please contact
SoClean to receive a modified injection fitting
(PN1116) at no charge. You may call 1(866) 501-3705 or email
support@soclean.com.
If you need help connecting to your specific machine, please visit our support pages at www.SoClean.cmoclean-support
Plug your AC adapter into the back of the SoClean and then into a wall outlet. Proceed to set your timer.
Your SoClean Timer & Display
Your SoClean timer will allow you to completely automate your daily cleaning.
The SoClean comes preset to start a 7 minute cleaning cycle at 10:00 am. First
set the clock to match your current time. You can easily change these settings
by following the steps on the next pages.
If you unplug the SoClean or experience a power loss, you will need to reset
the current time only. The disinfecting settings will remain saved. For safe
use, operate your SoClean only as instructed in this guide.
Cycle Indicator Light
- The lighted bar below the clock display indicates the status of the SoClean.
- RED when the SoClean is operating and generating activated oxygen.
- YELLOW when the SoClean is in its 2-hour disinfecting cycle.
- GREEN when disinfecting has been successfully completed.
The lighted display will turn off once the lid is lifted. For questions about the status indicator light, please see the FAQ on page 18.
Display Messages
Hose not present. Cycle will not run: This message displays during the manual
mode when there is no mask and hose
in the SoClean, the lid is not properly closed, or the hose slot plug is
missing or improperly seated.
Order filter kit:
This message displays after approximately 6 months of use as a reminder to
order a replacement filter and check valve kit.
Using Your SoClean
After the initial setup, using your SoClean unit is extremely easy. You will not need to disassemble any components to disinfect you equipment daily.
-
Open the lid.
-
Install the removable hose slot plug into one open slot.
-
Insert your mask into the chamber allowing its attached hose to rest in the open hose slot.
Note: The SoClean gives you the option of inserting your mask and hose from either side of the machine. To change sides, remove the hose slot plug from its position by lifting it straight out, and insert it into the slot on the opposite side.
- Close the lid.
The SoClean will now automatically operate according to its preset time and duration.
Note: The SoClean will never operate without the mask and hose present in
the securely closed chamber. Additionally, the SoClean will not operate if the
hose slot plug is missing or improperly seated.
Important: Even though the actual run time of the SoClean may only be 5 to 10
minutes, it is necessary to let the mask remain in the closed chamber for at
least 2 more hours. After that period, the cycle indicator light will shine
green as a sign that all disinfecting is complete and the mask is ready to be
removed from the chamber.
- Once cycle has completed, open the lid, remove mask and removable hose slot plug. Leave slot plug inside SoClean chamber. Store the slot plug inside the SoClean chamber.
Care and Maintenance for your SoClean
You may wipe down the SoClean with a damp cloth. The SoClean check valve and filter cartridge should be replaced every 6 months. A reminder message on the display will appear after approximately six months, depending on usage.
FAQ
-
Will my PAP equipment be wet from the SoClean? No. The SoClean disinfects with activated oxygen. No fluids or water are used in this process.
-
Is the SoClean harmful to me or the environment? No. The SoClean disinfects with activated oxygen. The same sanitizing technology is safely used on produce and drinking water. The SoClean produces activated oxygen in a closed system. The activated oxygen disinfects your equipment and naturally breaks down to regular oxygen within two hours. Additionally, any excess activated oxygen passes through a filter which converts it back to regular oxygen before release.
-
How do I know that my SoClean is disinfecting properly? After the disinfecting process has successfully completed, the status indicator light will shine green. Your PAP equipment will have a light, clean scent.
-
What if the scent the SoClean leaves is too strong for me? First, try washing your equipment with the Neutralizing Pre-wash. If the smell is still strong, you may try any of these steps: (1) Before wearing your mask at bedtime, run your PAP for 20 seconds to allow any residual scent to blow out. (2) Set the timer so that the machine runs earlier in the day, allowing any residual scent to dissipate by nighttime.(3) Increase the cycle duration time up to 12 minutes for a few days, and then reduce the time to your preferred setting. A strong odor usually indicates a high amount of oxidized organics.
-
What if my indicator light is shining red or yellow? This means that the disinfecting process is not yet complete. Please wait until the light shines green to remove your PAP equipment from the SoClean chamber. (See page 14)
-
It has been more than two hours since the SoClean completed a cycle, but the status
- light is still yellow. Why?
Some types of indoor lighting may make it difficult to distinguish the yellow and green lights on the SoClean. If two hours have passed since the SoClean completed a cycle, your PAP equipment is disinfected and ready for use.
- light is still yellow. Why?
-
What if the indicator light is not shining after a scheduled cleaning time? The SoClean did not complete a disinfecting cycle successfully. Common reasons for this are that the lid was not securely closed, there was no mask in the chamber at cleaning time or the hose slot plug is missing or not properly seated.
-
What if I missed my scheduled disinfecting time, but still wish to disinfect my equipment? You can use the Manual feature to run a cycle. (See page 13)
-
Why does my display say Order Filter Kit?This message appears approximately every 6 months, depending upon usage, as a reminder to regularly replace the filter and check valve. You can purchase the filter and check valve together in a Cartridge Filter Kit. To reorder, contact your authorized reseller or visit www. SoClean.com.
-
Are there materials that I should avoid putting into the SoClean? Nylon and natural rubber break down when exposed to activated oxygen. Most manufacturers typically do not use these materials in their reservoirs, hoses, masks or headgear. If you have questions, contact your PAP manufacturer, supplier or SoClean.
-
My mask feels oily, what should I do?Skin chemistry is unique. Some individuals with an oily skin type may need to hand-wash the mask occasionally. If you hand-wash your mask, be sure to use the Neutralizing Pre-wash or a fragrance-free, dye-free dish soap.
For further questions or concerns, please visit our website www.SoClean.com.
Classification, Symbols, FCC Notice
CLASSIFICATION
Class lla According to 93/42/EEC MDD Annex IX,Sect lll,Rule 15 PAP
Disinfecting device
SYMBOLS
- Consult Manual
- Complies with Medical Device
- Directive of the European Union.
- Serial Number
- Waste Electrical and Electronic Equipment (WEEE) It is the responsibility of the end user to dispose of this equipment at a designated collection point.
- Operating temperature conditions
FCC NOTICE
Please note that changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
USER GUIDE
For more information about SoClean 2
or our other innovative products, please visit
www.SoClean.com
References
- SoClean | Bettering Lives Through the Power of A Better Clean
- SoClean | Bettering Lives Through the Power of A Better Clean
- SoClean 2 Support | SoClean U.S.