microsonic ucs-24-CDD-QM Ultrasonic Proximity Switch User Manual

June 9, 2024
microsonic

microsonic LOGO ucs-15-CDD-QM Ultrasonic Proximity Switch
User Manual

Ultrasonic Proximity Switch with two antivalent switching outputs ucs-15/CDD/QM ucs-15/CEE/QM

Product Description

The usc sensor offers a non-contact measurement of the distance to an object which must be positioned within the sensor’s detection zone. Both switching outputs are set antivalent in dependence of the adjusted detect distance. Via a button, the detect distance and the operating mode can be adjusted (Teach- in). One LED indicates the state of the switching outputs.
Using the Link Control adapter (optional accessory) and the Link Control software for Windows®, all Teach-in and additional sensor parameter settings can be optionally adjusted.

Safety Notes

  • Read the operating manual prior to start-up.
  • Connection, installation and adjustments may only be carried out by qualified staff.
  • No safety component in accordance with the EU Machine Directive, use in the area of personal and machine protection not permitted.

Installation

  • Mount the sensor at the place of fitting.
  • Connect a connection cable to the M12 device plug.

Start-up

  • Connect the power supply.
  • Set the parameters of the sensor according to diagram.

Factory Setting

  • Synchronous mode deactivated
  • D1 = NCC, D2 = NOC
  • Detect points on operating range

Available Operating Modes

  • Operation with one detect point
  • Window mode
  • Two-way reflective barrier

The two switching outputs always switch antivalent.
Synchronization
With the synchronous mode activated and an electrical interconnection of the Sync/Com inputs (pin 5), up to 10 sensors can be synchronized.

Maintenance

micro sonic sensors are maintenance free. With heavy dirt deposits, we recommend a cleaning of the white sensor surface.
Notes

  • The usc sensor has a blind zone, within which distance measurements are not possible.
  • The ucs sensor is equipped with an internal temperature compensation. Due to the sensor’s self-heating, the temperature compensation reaches its optimum working point after approx. 30 minutes of operation.
  • In the normal operating mode, a yellow LED signals that the switching output D2 is switched through.
  • In the Teach-in mode, the hysteresis are reset to factory setting.
  • In the »Two-way reflective barrier« operating mode, the reflector is surrounded by a symmetrical window of ±8 % of the distance value.
  • If the button is not pressed for 30 seconds during the teach-in setting, the setting made hitherto is deleted.
  • The sensor can be reset to its factory setting.

Technical data

microsonic ucs 15 CDD QM Ultrasonic Proximity Switch -
Dimension| microsonic ucs 24 CDD QM
Ultrasonic Proximity Switch - Dimension
---|---
Blind zone| 55 mm
Operating range| 240 mm
Maximum range| 350 mm
Angle of beam spread| see detection zone
Transducer frequency| 500 kHz
Resolution, sampling rate| 0.08 mm
Reproducible| ±0.15 %
Accuracy| Temperature drift internal compensated, ≤2 %, may be deactivated 1)
Operating voltage UB| 10 to 30 V DC, reverse polarity protection
Voltage ripple| ±10 %
No-load current consumption| <45 mA
Housing| Zinc die-cast, plastic parts: PBT,
ultrasonic transducer: polyurethane foam, epoxy resin with glass content
Class of protection to EN 60529| IP 67
Type of connection| 5-pin M12 initiator plug
Controls| 1 Teach-in button
Indicators| 1 Duo-LED yellow/green
Programmable| via Link Control
Synchronization| internal
Operating temperature| –25 to +70 °C
Storage temperature| –40 to +85 °C
Weight| 65 g
Switching output| 2x pnp, UB–2 V/2x npn, –UB+2 V
Imax = 2x 200 mA
antivalent switchable, short-circuit-proof
Switching hysteresis 1)| 2 mm
Switching frequency 1)| 25 Hz
Response time 1)| 30 ms
Time delay before availability| < 300 ms
Norm conformity| EN 60947-5-2
Order no.
microsonic ucs 15 CDD QM Ultrasonic Proximity Switch - Figure
11) Can be programmed via Link Control| microsonic ucs 15 CDD QM Ultrasonic Proximity Switch - Figure
2

Set sensor via Teach-in procedure

Set antivalent switching outputs D1 and D2

microsonic ucs 15 CDD QM Ultrasonic Proximity Switch - Figure
3

Further settings

microsonic ucs 15 CDD QM Ultrasonic Proximity Switch - Further
settings

microsonic LOGO micro sonic GmbH
Phoenixseestraße 7
44263 Dortmund
Germany
T +49 231 975151-0
F +49 231 975151-51
E info@microsonic.de
W microsonic.de
The content of this document is subject to technical changes.
Specifications in this document are presented in a descriptive way only.
They do not warrant any product features. 2014/30/EUmicrosonic ucs 24 CDD
QM Ultrasonic Proximity Switch - Bar Code

Documents / Resources

| microsonic ucs-24-CDD-QM Ultrasonic Proximity Switch [pdf] User Manual
ucs-24-CDD-QM Ultrasonic Proximity Switch, ucs-24-CDD-QM, Ultrasonic Proximity Switch, Proximity Switch, Switch
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

microsonic User Manuals

Related Manuals