OPTEX OVS-50TNR Battery Operated Photoelectric Detector Instruction Manual
- June 6, 2024
- OPTEX
Table of Contents
OVS-50TNR Battery Operated Photoelectric Detector
BATTERY OPERATED PHOTOELECTRIC DETECTOR
OVS-50TNR
No. 59-2882-1
INSTALLATION INSTRUCTIONS
MODEL
DETECTION RANGE
OVS-50TNR
50 ft. / 15 m
FEATURES
· Easy installation with battery driven transmitter · 8 years battery life
with 2pcs. of SAFT LSH-20 · Simplified optical adjustment -Sniper View Finder
with ×2 magnification
1 INTRODUCTION
· Slim body design · Easy to see LED optical alignment · IP65 waterproof structure · Outdoor use / Usage extérieur
1-1 BEFORE YOUR OPERATION
The system must install in ordinary locations in accordance with the in Canada
general requirements are given in CSA Standard C22.2 No.0, General
Requirements Canadian Electrical Code, Part II.
· Read this instruction manual carefully prior to installation. · After
reading, store this manual carefully in an easily accessible place for
reference. · This manual uses the following warning indications for correct
use of the product, harm to you or other people and damage to your assets,
which are described below.
Be sure to understand the description before reading the rest of this manual.
Warning
Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage.
Caution
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage.
This symbol indicates prohibition. The specific prohibited action is provided
in and/or around the figure.
This symbol requires an action or gives an instruction.
This symbol indicates recommendation.
Le non respect des instructions indiquées par signe et un Avertissement
mauvais maniement peuvent causer la mort ou des blessures
graves.
Attention
Le non respect des instructions indiquées par ce signe et un mauvais maniement peuvent causer des blessures et/ou des dommages matériels.
Ce symbole signifie interdiction. L’action interdite est décrite dans et/ou autour de l’image. Ce symbole demande une action ou donne une instruction.
Warning
Do not use this product for any other purpose other than its intended use on
automatic gates. This product is not intended for use on Industrial Doors or
Vertical gates and does not comply with UL 325 for those applications.
Do not touch the unit base or power terminals of the product with a wet hand
(do not touch when the product is wet with rain, etc.). It may cause electric
shock. Never attempt to disassemble or repair the product. It may cause fire
or damage to the devices. Do not use batteries that have different levels of
power remaining (i.e., new and used batteries). Not observing the above may
result in an explosion, leakage of electrolyte, emission of toxic gases or
other outcomes that may be harmful to people and property. [Handling of
Batteries] Do not recharge, short circuit, crush, disassemble, exceed heat
above 100°C (212°F), incinerate, or expose contents to water. Do not solder
directly to the cell.
Caution
Do not pour water over the product with a bucket, hose, etc. The water may
enter, which may cause damage to the devices. Clean and check the product
periodically for safe use. If any problem is found, do not attempt to use the
product as it is and have the product repaired by a professional engineer or
electrician.
Avertissement
N’utilisez pas ce produit à d’autres fins que son utilisation prévue sur les
portails automatiques. Ce produit n’est pas destiné à être utilisé sur des
portes industrielles ou des portails verticaux et n’est pas conforme à la
norme UL 325 pour ces applications.
Ne pas toucher l’unité ou les bornes électriques du produit avec une main
humide (ne pas toucher si le produit a été mouillé par la pluie, etc.). Il y a
un risque de choc électrique.
Ne jamais essayer de démonter ou de réparer le produit. Cela pourrait causer
un incendie ou endommager le dispositif.
Ne pas utiliser des batteries avec des niveaux de charges différents (par ex.,
des batteries neuves avec des usagées). Le non respect de ce qui précède peut
causer une explosion, une fuite d’électrolyte, une émission de gaz toxiques ou
une conséquence nocive aux personnes et aux biens.
[Manipulation des batteries] Ne pas recharger, court-circuiter, écraser,
démanteler, porter à une température supérieure à 100°C (212°F), incinérer, ou
exposer le contenu à de l’eau. Ne pas souder directement à la cellule.
Attention
Ne pas verser d’eau sur le produit avec un seau, un tuyau, etc. De l’eau
pourrait pénétrer et endommager l’appareil.
Nettoyer et vérifier périodiquement le produit pour une utilisation en toute
sécurité. Si vous rencontrez un problème, n’essayez pas d’utiliser le produit
en l’état, faites le réparer par un ingénieur ou électricien professionnel.
1-2 PRECAUTIONS
Install the unit at 13″ height from the ground level.
Do not install the unit on an unstable surface.
Do not install the pole in a location where sufficient stability can not be ensured.
Do not install the unit in trees, leaves, or other objects that may swing in the wind and block the beam.
Avoid installing the receiver in a location where rising or setting sun may go directly into the receiver.
13″ ± 2″ (330 ± 50 mm)
No less than 11″
www.GateOpenerSafety.com | 800-878-7829
| Sales@GateOpenerSafety.com
1-3 PARTS IDENTIFICATION
Main unit cover
Main unit
Back box
Main unit cover lock screw
Optical unit Optical lens
Optical alignment dial
Main unit mounting bracket
Viewfinder
Dip SW (Receiver only)
Battery Plate
Battery cover lock screw
Battery cover
Swivel Optical unit.
Accessories>>
4×25 self tapping for wall mounting (with rubber washer): 4
M4×16 screws for pole mounting
(with rubber washer): 4
Pole brackets: 2
U-brackets: 2
Interface board
2 INSTALLATION
2-1 SEPARATING (Transmitter & Receiver)
1 Remove the battery cover.
2 Remove the main unit cover.
3 Remove the connectors.
1 Loosen the battery cover lock screw.
2 Pull
4 Remove the main unit from the back box.
2
1 Loosen the main unit cover lock screw.
2 Pull
1
1 Turn the optical unit 90 degrees and loosen the screw.
3
2 Take the main unit out of the back box.
2-2 WIRING (Receiver only) 1 Open the battery plate, eject InterfaceBoard.
Battery Plate
2 Using a screwdriver or similar tool, break the
knockout position in the back box as shown.
3 Open the battery plate and then route the Gate Operater
wires from the rear of the back box through the knockout holes. Adjust the
wires so that they extend about 100mm (4 inch) from the holes.
Interface board
Gate Operater
www.GateOpenerSafety.com | 800-878-7829 | Sales@GateOpenerSafety.com
4 Fill the holes with the wires
using the some putty.
5 Insert Interface board into the slots on the back box and then connect
the wires to nterface board terminals.
6 Close the battery plate .
2-3 WALL MOUNTING (Transmitter & Receiver)
1 Using a screwdriver or similar tool, break the knockout position (×2)
in the back box as shown.
Knockout position
Open the screw holes from the inside of the back box to the outside.
WALL
POLE(1) POLE(2)
3 Mount the main unit.
1
2
2 Mount the back box to the wall.
Gate
In order to minimize some reflection from the gate,adjust horizontal angle
away from the gate.
4×20 self tapping (with rubber washer)
Distance from the ground 13″z (330Nm)
Pitch : 3.3 inch (83.5mm) For connection to gang electric box
4 Attach the connectors.
Note>> · Avoid placing the cables in a position where
they can be caught between the main unit and cover.
3
1 Route the two connectors of the back box through the slits on the upper part of the main unit.
2 Tighten the main unit fixing screw and turn the optical unit 90 degrees.
5 Replace batteries (Transmitter only).
1 Open the battery plate in the direction of the arrow. Insert the two
batteries into their compartment.
2 Ensure the positive terminals are facing toward the front.
3 Close the battery plate.
Disposal method for batteries Dispose of used batteries in accordance with
local government regulations/low and EU Battery Directive (2006/66/EU).
3
1
2 3.6 VDC D size Lithium batteries
Warning
· Do not mix batteries that have different levels of power remaining (i.e.,
new and used batteries or batteries of different manufacturers). Not observing
the above may result in an explosion, leakage of electrolyte, emission of
toxic gases or other outcomes that may be harmful to people and property.
Avertissement
· Ne pas mélanger des batteries avec des niveaux de charges différentes (par
ex. des batteries neuves avec des batteries usagées, ou des batteries de
fabriquants différents). Le non respect de ce qui précède peut causer une
explosion, une fuite d’électrolyte, une émission de gaz toxiques ou d’autres
conséquences dangereuses pour les personnes ou les biens.
Caution
· Remove all batteries prior to replacing with new ones. If this is not
followed, the low battery indicator LED will not reset and will continue to
blink.
Attention
· Enlever toutes les batteries avant d’en remettre de nouvelles. Cela
empêcherait la remise à zéro de la LED qui continuera de clignoter.
· Lors du retour de ce détecteur au fournisseur, retirez toutes les batteries
de l’émetteur et le récepteur.
www.GateOpenerSafety.com | 800-878-7829 | Sales@GateOpenerSafety.com
6 Referring to “4 SETTING” on page 5, perform the necessary settings.
7 Close the main unit cover.
1
8 Close the battery cover.
1
2
1 Hook on the upper part 2 Push the lower part of
of the back box.
the main unit cover.
3 Fasten the main unit cover lock screw.
Caution
· Do not touch the optical unit when mounting the cover. Otherwise, the
resulting shift of the optical axis may result in malfunction of the unit and
require readjustment.
Attention
· Ne touchez pas à l’unité optique lors du montage du couvercle. Sinon, le
déplacement résultant de l’axe optique peut entraîner un dysfonctionnement de
l’unité et nécessiter un réajustement.
2-4 POLE MOUNTING
1 Using the guide below, break the knockout positions (×2) in the back
box with a screwdriver.
Knockout position
Open the screw holes from the inside of the back box to the outside.
WALL
POLE(1) POLE(2)
Instruction condition
Knockout position Detector No. 1 Detector No. 2
One detector
POLE (1)
–
Two detectors in opposing directions
POLE (1)
POLE (2)
Caution
· If you accidentally open an unnecessary knockout, be sure to fill the
knockout. Not doing so may result in waterproof failure and malfunction of the
product.
Attention
· Entrée défonçable inutile mal cassée : elle doit être refermée avec un
matériau imperméable à l’eau. Sinon, cela peut entraîner un problème
d’imperméabilité et un mauvais fonctionnement du produit.
2-5 WIRING (Receiver only)
The Receiver Beam unit must power by UL approved Class 2 power supply.
Receiver
Output Fome C
NO NC COM PWR
Power 12-24VDC
2
3
Just fit
1 Close the battery cover.
2 Tighten the fixing screw for the battery cover.
Caution
· When closing the cover, be careful that the cables are not caught by the
cover.
Attention
· Lors de la fermeture du couvercle, veillez à ce que les câbles ne se
prennent pas dans le couvercle.
2 Fix the back box on the pole.
Gate
Pole bracket
In order to minimize some reflection from the gate,adjust horizontal angle
away from the gate.
M4×20 screw (with rubber washer)
Distance from the ground 13″z (330Nm)
Pole : 1.69″ to 1.89″ dia. (43 to 48 mm dia.)
U-bracket
3 Perform the wall mounting procedure of 5 to 8 on page 3.
Power Input
Interface board
Gate Operator
Receiver Main unit
www.GateOpenerSafety.com | 800-878-7829
| Sales@GateOpenerSafety.com
3 SETTINGS
3-1 FUNCTIONS
1 DIP SWITCH Refer to “1-3 PARTS IDENTIFICATION”.
Receiver
SELECTOR POSITION OVS-TNR
ON
1234
Beam interruption adjustment switch Disabled
(factory default)
2 BEAM INTERRUPTION ADJUSTMENT
Initial setting is at 20ms. Set the beam interruption adjustment switches of
the Receiver according to the required response time. If get longer, less
false alaarm.
Note>>
· Do not press the tamper when you set the DIP switches. Otherwise the
settings will not actually be changed.
3-2 OPTICAL ALIGNMENT
Optical alignment is an important procedure to increase reliability. Be sure to take alignment step 1 through 2 described below to attain the maximum level of the output through the monitor jack.
Horizontal alignment angle
Vertical alignment angle
5° 5°
90°
90°
Selector Position Interruption Time
ON
1234
1234 1234 1234
20msec 100msec 250msec 500msec
UL-325 complied setting.
2 Checking the Indicator LED and fine alignment
Checking of the indicator · After the rough alignment using the view finder,
check the light receiving status by the Alignment / Level Indicator.
Beam interrupted
Beam received
Alignment / Level ON Fast blink Slow blink
OFF
indicator LED
1 Look into the viewfinder and perform fine alignment of the horizontal and
vertical angles using the alignment dial.
Viewfinder
Adjust until another side sensor comes to center.
Note>> < How to look into the viewfinder >
Left eye
Right eye
From right side
From left side
Adjustment level
Realign
Fair Good Excellent
Monitor jack output 0 V 0.1 VDC
2.4 VDC
2.8 VDC
(PPENPSFUIBO7%$
Fine adjustment with monitor jack
· After checking the receiving level of optical axis by using the alarm
indicator, make sure to make fine alignment for both transmitter and receiver
with voltmeter until it reaches maximum monitor output over “Good” level.
Note>> · When making the adjustments by the monitor jack, be careful not to cover the optical unit with your hand, the voltmeter pin cord, etc.
< Receiver >Set the voltmeter range to 5 to 10VDC and connect the voltmeter probes and to and of the monitor jack respectively.
< Horizontal alignment > < Vertical alignment >Turn the horizontal alignment dial by fingers to make alignment
Turn the vertical alignment dial with a screwdriver to make alignment
Caution
· The Alignment / Level indicator LED is a supporting tool for easy alignment.
Be sure to perform fine alignment to ensure the maximum output level through
the monitor jack.
· The Alignment / Level indicator LED should only be used for rough alignment.
For fine or good alignment, always use the monitor jack output level.
Attention
· Le témoin de l’alarme/de niveau est un outil d’aide pour faciliter
l’alignement. Assurez-vous de réaliser réglage précis pour obtenir le niveau
maximum de sortie du point de test.
www.GateOpenerSafety.com | 800-878-7829 | Sales@GateOpenerSafety.com
4 OPERATION CHECK
4-1 LED INDICATION
Alignment / Level indicator LED (Receiver only)
Alignment / Level indicator LED
DETECTOR
Beam Interruption Beam not
received sufficiently
Beam Aligned
LED
ON (continue)
Fast blink
or
Slow blink
OFF
Power / Low battery indicator LED
Power / Low battery indicator LED
Transmitter and Receiver
BATTERY CONDITION
LED
Normal
Transmitter is low battery
ON (continue)
· · ·
Fast blink
4-2 OPERATION CHECK
After installation is complete, be sure to check the operation.
1
Make sure that the Alignment / Level indicator LED is OFF. If it is illuminated even when the beams are not blocked,
make optical alignment again.
2 Check that the Power / Low battery indicator LEDs on both
transmitter and receiver are ON. If the Power / Low battery indicator LED is
blinking, the battery power is low. Replace with new batteries.
3 Conduct a walk test to check that Alignment / Level indicator
LED on the receiver turns ON as the walker interrupts the beams.
Transmitter
Receiver
A
C
B
Be sure to conduct a walk test at the following three points: A. In front of the transmitter B. In front of the receiver C. At the mid point between the transmitter and receiver
The detector is installed properly when Alignment / Level indicator LED turns solid ON in the tests at all the three points.
5 TROUBLESHOOTING
PROBLEM
Power / Low battery indicator LEDs are not illuminated. (Receiver)
Power / Low battery indicator LEDs are not illuminated. (Transmitter) Output
is not sent.
When the beam is blocked, the “OUTPUT” indicator LED is illuminated but the
Output is not activated. Output is activated even if the light is not blocked.
Batteries are running out too quickly. Frost, snow or heavy rain causes
activation.
Improper output Even if new batteries are used, Low battery indicator LED is
ON.
POSSIBLE CAUSE
Power may not be supplied. The supply voltage may not be correct. The power
supply polarity is wrong. Reversed battery polarity.
Reflection from the floor or wall. Beam has not been blocked. Signal line
short-circuited.
Surface of Transmitter/Receiver cover soiled. Optical alignment was not
performed properly. Main unit cover is not set properly. Optical alignment not
optimized. Too much snow or frost accretion. Problem with wiring. Batteries
are inactive condition.
CORRECTIVE ACTION
Connect power supply of 12-24VDC. Check Power supply voltage 12-24VDC. Check
power supply polarity. Check the battery polarity.
Align beams away from the floor or wall. Block all two beams. Check the
wiring.
Clean the cover (wipe the cover with a soft cloth dampened with water or
diluted neutral detergent). See “3-2 OPTICAL ALIGNMENT” on page 5 and make
realignment. Set the cover properly. See “3-2 OPTICAL ALIGNMENT” on page 5 and
make realignment. Remove snow or frost on the cover. Install the correct
wiring. Clean up the battery terminal if it is covered with an oxide film or
soil.
www.GateOpenerSafety.com | 800-878-7829 | Sales@GateOpenerSafety.com
6 SPECIFICATIONS
Model Detection range Detection method Interruption time Operation frequency
Power source
Current draw
Battery life *** Output
LSH-20 by SAFT Output Output hold time Resistive Termination
Indicator LED
Output / Level indicator (Receiver)
Power/ Low battery indicator (Transmitter )
Operating temperature Operating humidity Alignment angle Dimension
Weight
International protection
OVS-50TNR 50 ft. / 15 m Twin infrared beam interruption detection Variable between 20/100/250/500 ms (4 steps) 200Hz Transmitter : 3.6 VDC D size lithium batteries (2 units) Receiver : 12 – 24 VDC Transmitter : 130µA (25°C, DC3.6V) Receiver : 80mA (max.) Approx. 8 years (Transmitter) Form C relay ; 30VDC. 0.2A Blocked beam period +0.5 sec 10K ohm across NO contact ON : Beam not received Blinking : Beam not received sufficiently OFF : Beam received ON : Power ON Blinking : Low voltage OFF : Power OFF -20°C to +60°C (-4°F to 140°F) 95 % (max.) ±90° Horizontal / ±5° Vertical H × W × D inch (mm) : 11.6 (295) × 2.7 (69) × 4.6 (117) 1200 g (42.3 oz) (Total weight of Transmitter + Receiver, excluding accessories) IP65
Specifications and design are subject to change without prior notice. * The value is based on the condition that it is used within the ambient temperature range of 20 to 25°C. ** Using batteries other than those recommended may shorten the battery life.
7 DIMENSIONS
2.7 (69)
3.3 (83.5) (WALL)
11.6 (295)
4.6 (117)
Unit : inch (mm)
www.GateOpenerSafety.com | 800-878-7829 | Sales@GateOpenerSafety.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>