OPTEX AP-360BR(C) Indoor Recessed Mount Battery Operated 360 Degree PIR Detector Instruction Manual
- June 1, 2024
- OPTEX
Table of Contents
OPTEX AP-360BR(C) Indoor Recessed Mount Battery Operated 360 Degree PIR
Detector
Before installation
Manufacturer’s statement
Symbol Meaning
- Warning: Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.
- Caution: Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.
Symbol Meaning
- Check mark indicates a recommendation.
- Nix sign indicates prohibition.
NOTE: Special attention is required to the section of this symbol.
Warning
Caution
Parts Identifications
Accessories
Settings
Disassemble
Jumper pin settings
Assemble
Installation
Ceiling mount without switch box
- Install a retaining spring on both sides. (follow the illustrated arrow steps to complete the assembly of the retaining spring.)
- Make a ø45 mm (1.77”) hole in the ceiling for mounting.
- Insert the detector into the hole with the retaining spring facing up.
- Mount the detector on the ceiling. (Be sure to arrange the wires with a downward slope to prevent water ingress into the detector.)
Ceiling mount with 86-type box
NOTE
For the 86-type box mount, dual 86-type boxes are recommended with the additional one used to accommodate the transmitter.
- Prepare an 86-type box on the ceiling.
- Install the detector into the 86-type box.
NOTE
-
Align the bump with the triangle recess as illustrated in the figure.
-
Fix the detector with two screws and cover their heads with two caps.
Wiring
Transmitter
Checking
Walk test
- Power on.
- Wait for 60 seconds to complete the warm-up time.
- Walk in the detection area to check the detecting performance.
- Start operation.
Specifications
Model | AP-360BR(C) |
---|---|
Detection method | Passive infrared |
Detection area | ø6 m (ø20’ at mounting height: 4.5 m (14’9” ft.) |
Mounting height | 2.5 to 4.5 m (8’2” ft. to 14’9” ft.) |
Mounting mode | Recessed ceiling mount/86-type box mount |
Sensitivity | 2.0℃ at 0.6 m/s (3.6°F at 2’/s) |
Detection speed | 0.3 to 3.0 m/s (1‘/s to 9’10”/s) |
LED indicator
| Warm-up upon power on blinking Stand-by: off
Walk test: solid on Alarm: off
Alarm cycle| Approx. 2 s
Battery saving timer| 120 s/ 5 s selectable
Alarm output| N.O./N.C., 3.6 V DC 10 mA max.
Tamper switch
| N.C. 28 V DC 100 mA max.
The contact opens once the casing is detached.
Warm-up time| Approx. 60 s
Power supply| 2.7 to 3.6 V DC (CR123A battery)
Current
| 3 V DC
Stand-by: 10цA, Max.: 4 mA
PIR sensitivity| H/ M/ L
Weight| 50 g (1.76 oz)
Operation temperature| -20 to +50℃ (-4°F to +122°F)
Operation humidity| < 95%
Location| Indoors
Dimensions
| ø52 x 42.5 mm (ø2.05 in. x 1.67 in.): without switch box mount
86 x 86 x 42.5 mm (3.39 x 3.39 x 1.67 in.): with 86-type box mount
- Specifications and designs are subject to change without prior notice.
- These units are designed to detect an intruder and activate an alarm control panel.
- Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
Dimensions
Detection area
Top view
Maximum detection area
Mounting height
| 2.5
(8’ 2’ )
| 3.0
(9’ 10” )
| 3.5
(11’ 6” )
| 4.0
(13’ 1” )
| 4.5
(14’ 9” )
---|---|---|---|---|---
Detection area
| ø3.3 (ø10’ 10” )| ø4.0 (ø13’ 1” )| ø4.6 (ø15’ 1” )| ø5.4 (ø17’ 8” )| ø6.0 (ø20’ )
Unit: m (ft., in.)
Side view
Timing chart
Troubleshooting
CONTACT
OPTEX INC./AMERICAS HQ (U.S.)
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
OPTEX SECURITY B.V. (The Netherlands)
OPTEX SECURITY SAS (France)
OPTEX SECURITY Sp.z o.o. (Poland)
OPTEX PINNACLE INDIA,
- PVT., LTD. (India)
- www.optexpinnacle.com
OPTEX KOREA CO., LTD. (Korea)
OPTEX (DONGGUAN) CO.,LTD.
- SHANGHAI OFFICE (China)
- www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
- www.optex.co.th
- Copyright (C) 2022 OPTEX CO., LTD.
EU & UK contact information
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>