omtech CW-3000 Series Industrial Refrigeration Chiller User Manual

June 5, 2024
omtech

omtech -logoomtech CW-3000 Series Industrial Refrigeration Chilleromtech
CW-3000 Series Industrial Refrigeration Chiller product

SAFETY INFORMATION

Warning!

  • DO NOT run this chiller without first providing adequate water. (See page 3.) Deionized or distilled water is preferrable.
  • ONLY use with stable, compatible, and well-grounded power supplies. See page 5 for the correct voltage for your model.
  • Place this chiller in a well-ventilated, dry environment away from heat sources but warm enough to avoid freezing temperatures.
  • Leave at least 1 foot (30 cm) of space behind the rear air outlet.
  • Leave at least 4 inches (10 cm) of space around the two side air inlets.
  • Do not allow children or untrained persons to use this chiller.
  • Pay attention to possible condensation on the chiller and its water lines. If condensation is observed, raise the water temperature, keep the water lines and cooled components warmer, or reduce ambient humidity until no condensation occurs.
  • When cooling a laser engraver, take care that this device does not cause the room’s humidity to exceed safe levels.
  • Do not all the air filter to become blocked by dust. Clean it regularly.
  • Disconnect the power and drain all water from the chiller before storage or transport. Caution!
  • Remember that the OUTLET of the water chiller should connect to the INLET of the product to be cooled. Similarly, the water chiller’s inlet should be connected to the other machine’s water outlet.

PACKAGE LIST

  • 1 × Industrial Chiller
  • 1 × Power Cord
  • 1 × Alarm Signal Output Plug
  • 1 × Spare Fuse (held near the rear power socket) 1 × Instruction Manual

PARTS DIAGRAM

FRONTomtech CW-3000 Series Industrial Refrigeration Chiller fig
1

BACKomtech CW-3000 Series Industrial Refrigeration Chiller fig
2

INSTALLATION

It is very simple to install this industrial chiller.

  1. Open the package to check that the machine is intact and all the necessary accessories are included.

  2. Open the injection port and add water. For best results, use deionized water.
    Pour slowly and do not fill the chiller completely. There should be about 3–6 inches (8–15 cm) between the opening and the top of the water in the machine. Do not allow the water to overflow.
    For cooling carbon steel equipment, the water should have the appropriate amount of anticorrosive additive.

  3. Connect the water inlet and outlet pipes to the system you wish to cool. Be sure to connect the chiller’s OUTLET pipe to your system’s INLET port and the chiller’s inlet pipe to the system’s outlet port.

  4. Plug in the power and flip the power switch. The pump will begin working.
    There may be some bubbles at first. These should disappear after a minute or two.
    Don’t worry if the fans and other components of the chiller do not activate. They are usually automatically controlled and will not begin working until they are needed by the machine.
    In different conditions, the time for startup may vary from seconds to a few minutes. Do not become frustrated and switch the machine on and off, except when necessary to add water.omtech CW-3000 Series Industrial Refrigeration
Chiller fig 33

  5. Check the water level of the water tank again, as in Step 2 above. The water level of the chiller will lower somewhat as it fills the cooling path of your machine. If necessary, carefully add more water to the chiller to maintain a level about 3–6 inches (8–15 cm) below the top of the chiller.
    If the water level drops sharply or continues to go down during normal use, turn off your devices and examine the water pipes and cooling path for leakage. Repair any such leaks before restarting the devices and continuing work.

ALARMS

Alarm Lights and Sounds

DISPLAY

CONDITION

| Indicator Lights| Alarm| H1/H2

Output

| H1/H3

Output

---|---|---|---|---
Normal| On      Off| None|  Off| On
Blocked pathway| Off      On|  Buzzing| On|  Off
Water above 140°F (60°C)| Off      On|  Buzzing| On|  Off
Faulty pump| Off      On|  Buzzing| On|  Off
Water shortage| Off      On|  Buzzing| On|  Off
Electrical circuit failure| | | On|  Off
Power interruption| | | On|  Off

Note that the flow alarm is connected to relay contacts requiring that the operating current be less than 5A and working voltage less than 300V.

Alarm Circuitomtech CW-3000 Series Industrial Refrigeration Chiller fig
5

MAINTENANCE

  • Clean with a soft damp cloth and mild soap. Never allow water to enter the chiller’s electrical components. Do not use caustic chemicals or harsh abrasives.
  • Always keep the vents clean and unobstructed and the filters clear.
  • Periodically confirm that no dust or debris has entered the water tank of your chiller. If any is found, empty and clean the tank completely before continuing use.

SPECIFICATIONS

Model CW-3000AG CW-3000DG
Voltage 220V 110V
Frequency 50Hz 60Hz
Current 0.45A 0.9A
Cooling 27.8W/°F (50W/°C)
Capacity 2.4 US gal. (9L)
Port Dia. 10 mm
Max. Lift 32.8 ft. (10 m)
Max. Flow 2.6 gpm (10 L/min.)
Net Weight 20.9 lb. (9.5 kg)
Dimensions 19×11×15 in. (48.3×27×38 cm)

TROUBLESHOOTING

Never use a dangerous system like a laser engraver if the water cooling system is malfunctioning. If the laser or other dangerous device is already on, shut it down immediately and correct the problem with the chiller before using it again.

Failure Approach

The machine has no power.

| Check that the power cord is firmly connected.
Cut the device’s power and pull out the fuse box from the back of the machine. If the fuse has blown, ensure that the power supply is stable or install a voltage regulator. Replace the fuse with the spare stored in the fuse box.

The machine is on, but the water

does not flow.

| Check that there are no leaks in the water pipes or cooling pathway. Then add more water until it reaches the correct height.
The water is flowing but there is an alarm.| Check that there are no leaks in the pipes and add more water.

The water temperature is too high.

| Check that the chiller has proper room for ventilation and the air filter is clean.
Ensure that the power supply is stable or install a voltage regulator.
Ensure that there is sufficient time for refrigerator to occur before activating the device you want to cool. At most, with a functioning machine, this should take less than 5 minutes.
Reduce the heat load or upgrade to a stronger chiller.

The fan does not turn on.

| This is normal when the water is below 70°F. If the water is heated and the fan still does not operate, contact customer service.

The room temperature is too high.

| Ensure the chiller has proper room for ventilation (See p. 1). If it already does, take action to cool the surrounding work space.
There is constant condensation around the machine and the water lines.| Increase the water temperature or heat the area around the cooling path. Failing this, take action to reduce the ambient humidity of the surrounding work space.
Water drains slowly.| Open the injection port.

Thank you for choosing our products! If you have any questions or comments, contact us at [email protected] and we’ll resolve your issue ASAP!