OPTEX FLX-S-ST FlipX Series Flexible Range Indoor Detector Instruction Manual

June 9, 2024
OPTEX

FLX-S-ST FlipX Series Flexible Range Indoor Detector

Product Information

Flexible Range Indoor Detector

The Flexible Range Indoor Detector, FlipX series is a standard model that comes with a wide/narrow area PIR flip lens and a microwave mounting bracket. It is available in different models such as FLX-S-ST, FLX-S-ST-BKT, FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8, and FLX-S-DT-X9. The FLX-S-DT-X5 and FLX-S-DT-X5-BKT models operate at 10.525GHz while the FLX-S-DT-X8 operates at 10.587GHz and the FLX-S-DT-X9 operates at 9.425GHz. The product is not certified to INCERT, SBSC, EN 50131-2-2 (FLX-S-ST-BKT)/EN 50131-2-4 (FLX-S-DT-X5-BKT/X9), and UL.

Product Usage Instructions

Before Installation

Before installation, please read the manufacturer’s statement and identify the parts required for installation. Pay attention to the symbols provided in the manual. A warning symbol indicates that failure to follow instructions may cause death or serious injury, while a caution symbol indicates that failure to follow instructions may cause injury and/or property damage.

Installation

To install the Flexible Range Indoor Detector, follow the steps below:

  1. Disassemble the product
  2. Mount the product on the wall without the bracket or with the bracket
  3. Assemble and connect the product

Settings

The Flexible Range Indoor Detector comes with jumper pin settings and a wide/narrow setting. Please refer to the manual for instructions on how to set these.

Checking

After installation, it is important to check the product to ensure that it is functioning properly. Please refer to the manual for instructions on how to check the product.

Others

The manual also provides information on the specifications of the product, including its dimensions, detection area, and angle adjustment with bracket CW-G2. It also includes information on compliance.

INSTALLATION INSTRUCTIONS

| Wide/Narrow area

Flip lens

| PIR| Microwave| Mounting bracket
---|---|---|---|---
FLX-S-ST| ✓| ✓| –| –
FLX-S-ST-BKT3| ✓| ✓| –| ✓
FLX-S-DT-X5
1| ✓| ✓| ✓   (10.525GHz)| –
FLX-S-DT-X5-BKT3| ✓| ✓| ✓    (10.525GHz)| ✓
FLX-S-DT-X8
2| ✓| ✓| ✓   (10.587GHz)| –
FLX-S-DT-X9*3| ✓| ✓| ✓     (9.425GHz)| –

  1. Not certified to INSERT
  2. Not certified to SBSC and UL
  3. Not certified to EN 50131-2-2 (FLX-S-ST-BKT)/EN 50131-2-4 (FLX-S-DT-X5-BKT/X9), INCERT, SBSC and UL

Contents

OPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-
fig-1

Before installation

Manufacturer’s statement

Symbol/Meaning

  • Warning: Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.

  • Caution: Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.

  • The check mark indicates a recommendation.

  • The Nix sign indicates prohibition.

  • NOTE: Special attention is required to the section of this symbol.OPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-fig-3 OPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-fig-4

Parts identifications

OPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-
Indoor-Detector-fig-5

Installation

Disassemble

  1. Unlock the cover
  2. Open the cover
  3. Remove the main unit

Wall mount without bracket

  1. Wire through the base
    • How to break the knockoutsOPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-fig-11
  2. Mount the base

Mounting holes

  • a. Wall mount
  • b. Corner mount

NOTE

Mounting screws are not included. Φ 3 mm screws are recommended.

Wall mount with bracket

  1. Wire and mount on the wall
  2. Join the base on the bracket

NOTE

  • Adjust the detection direction while jointing. Confirming with a walk test is required. –> Refer to “3-1. Walk test”OPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-fig-17
  • Fix the base with the fixing screws (optional)

Ceiling mount with bracket

How to change the bracket to the ceiling mounting

  1. Loosen the fixing screw.
  2. Rotate the body.
  3. Tighten the fixing screw.OPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-fig-20

Wire and mount on the ceiling

NOTE: See page 4 for how to break the knockouts.

Join the base on the bracket

NOTE: Adjust the detection direction while jointing. Confirming with a walk test is required. –> Refer to “3-1. Walk test”

NOTE: Mounting screws are not included. Φ 3 mm screws are recommended.

Fix the base with the fixing screws (optional)

Assemble and connect

  1. Attach the main unit to the baseOPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-fig-25
  2. Connect wires to the terminalOPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-fig-26

Power cable length
The power cable should be limited to the following length. FLX-S-ST FLX-S-DT

WIRE GAUGE 12 V DC 14 V DC WIRE GAUGE 12 V DC 14 V DC

AWG 22

(0.33 mm²)

| 520 m

(1,710 ft.)

| 1,130 m

(3, 718 ft.)

| AWG 22

(0.33 mm²)

| 410 m

(1,350 ft.)

| 890 m

(2,920 ft.)

AWG 20

(0.52 mm²)

AWG 18

(0.83 mm²)

| 820 m

(2,690 ft.)

| 1,790 m

(5,870 ft.)

| AWG 20

(0.52 mm²)

AWG 18

(0.83 mm²)

| 650 m

(2,130 ft.)

| 1,400 m

(4,590 ft.)

1,320 m

(4,330 ft.)

| 2,850 m

(9,350 ft.)

| 1,030 m

(3,380 ft.)

| 2,240 m

(7,350 ft.)

Settings

Jumper pin settingsOPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-
Detector-fig-27

Wide/Narrow setting

  1. Set the Flip lens to “Wide” or “Narrow”

Go to 2-2 to skip 2-19 when using the default “Wide” setting.OPTEX-FLX-S-ST-
FlipX-Series-Flexible-Range-Indoor-Detector-fig-28

NOTE: Install the lens so that the letters on the cover and on the lens match your intention.

How to remove the lens

Caution

Be careful not to damage the light path of the LED. Also, be careful not to allow the light path to pinch the wiring when closing the cover.

Caution

Be careful not to damage the lens with a screwdriver.

How to install the lens

Push the lens firmly at 3 points in numerical order.OPTEX-FLX-S-ST-FlipX-
Series-Flexible-Range-Indoor-Detector-fig-31

Set the jumper pin to “Wide” or “Narrow”

Caution

The jumper pin must be “Narrow” when the lens is set to “Narrow” .

NOTE

  • The default setting is “Wide”.
  • When “Narrow” is selected, MW detection will be disabled.

Checking

Walk test

  1. Confirm that the LED pin is “ON” , then close the cover.
  2. Walk in the detection area to check the detecting performance via LED indication.
  3. Return the LED pin to “OFF” after the walk test, if necessary.
  4. Lock the cover

NOTE
Conduct a walk test at least once a year.

Others

Specifications

Model FLX-S-ST (-BKT) FLX-S-DT-X5(-BKT)/-X8/-X9

Installation
Detection method| Passive infrared| Passive infrared and Microwave
Coverage| Wide:12 m (40 ft.) 85°/ Narrow:18 m (60 ft.) 5°

( No MW detection at “Narrow” setting )

Detection zones| Wide: 76 zones/ Narrow: 12 zones
Mounting height| 2.0 to 3.0 m (6’7″ to 9’8”)
Alarm period| 2.0 ± 0.5 s
Warm-up period| Approx. 60 s (LED blinks)
LED indicator| Switchable ON/OFF Green: [1] Warm-up    [2] Alarm
Electrical
Power input| 9.5 to 16 V DC UL *
Current draw| 8 mA (normal)

11 mA (max.) at 12 V DC

| 11 mA (normal)

14 mA (max.) at 12 V DC


Relay output

| Alarm| N.C. 24 V DC 0.1 A max. (Resistive load)
Tamper| N.C. 24 V DC 0.1 A max. (Resistive load)

(Open when the cover is removed.)

Remote LED| **| Terminal: open = OFF 0 V = ON
Environmental
Operation temperature| -20℃ to +50℃(-4°F to +122°F)| -20℃ to +45℃(-4°F to +113°F)
Temperature compensation| Digital (SMDA)
Environmental humidity| 95% max.
RF interference| No alarm 10 V/m
Mechanical**
Dimension| H: 129.2 x W: 61.5 x D: 50.9 mm (H: 5.09” x W: 2.42” x D: 2.00”)
Weight| Approx. 90 g (3.17 oz)

(with Bracket : Approx. 120 g (4.23 oz))

| Approx. 105g (3.7 oz)

(with Bracket : Approx. 135 g (4.76 oz))

Mounting| Wall, Corner (Indoor)

(with Bracket : Wall, Corner, Ceiling)

  • Specifications and designs are subject to change without prior notice.
  • These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
  • UL: Shall be powered via a UL listed burglar alarm class 2 output power limited power supply that has a min standby power of 4 hrs.

Dimensions

OPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-
fig-37

Detection areaOPTEX-FLX-S-ST-FlipX-Series-Flexible-Range-Indoor-Detector-
fig-38

NOTE

  • The dotted line indicates the recommended mounting height.
  • When “Narrow” is selected at the jumper pin, MW detection will be stopped.
  • Narrow area settings are not certified to the following standards. EN 50131-2-2 (FLX-S-ST)/EN 50131-2-4 (FLX-S-DT), INCERT and SBSC.

Angle adjustment with bracket CW-G2OPTEX-FLX-S-ST-FlipX-Series-Flexible-
Range-Indoor-Detector-fig-39

Compliance

RE Directive 2014/53/EU

  • OPTEX declares that FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8, and FLX-S-DT-X9 comply with RE Directive 2014/53/EU. Doc documents can be found on our website; www.optex.net
  • Microwave Emission Frequency and Power
  • FLX-S-DT-X5: 10.525 GHz 15.78 mW e.i.r.p
  • FLX-S-DT-X5-BKT: 10.525 GHz 15.78 mW e.i.r.p
  • FLX-S-DT-X8: 10.587 GHz 8.93 mW e.i.r.p
  • FLX-S-DT-X9: 9.425 GHz 14.50 mW e.i.r.p
  • The following list indicates the areas of intended use of the equipment and any known restrictions. For countries not included in this list, please consult the responsible Spectrum Management Agency.
  • 10.525 GHz Belgium, Denmark, Finland, Germany, Greece, Italy, Luxembourg, The Netherlands, Spain, Sweden, Iceland, Norway, Switzerland
  • 10.587 GHz Belgium, France, Germany, Ireland, Luxembourg, The Netherlands, United Kingdom
  • 9.425 GHz Austria, Czechia, Esthonia, Germany, Slovakia, Turkey, Russia
  • FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8, and FLX-S-DT-X9 also comply with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
  • EN 50131-1 Grades and Environmental Class; Security Grade 2, Environmental Class II Applied Standards; EN 50131-2-2 (FLX-S-ST), EN 50131-2-4 (FLX-S-DT-X5 and FLX-S-DT-X8)
  • Tested and certified by Telefication
    • larm klass 2, miljö klass II, SSF 1014
  • PD6662:2017
    • UL/c-UL listed (FLX-S-ST and FLX-S-DT-X5)
  • EU & UK contact information
  • https://navi.optex.net/cert/contact/
  • OPTEX CO., LTD. (JAPAN)
  • www.optex.net
  • OPTEX INC./AMERICAS HQ (U.S.)
  • www.optexamerica.com
  • OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
  • www.optex-europe.com
  • OPTEX SECURITY B.V.
  • (The Netherlands)
  • www.optex-europe.com/n
  • OPTEX SECURITY SAS (France)
  • www.optex-europe.com/fr
  • OPTEX SECURITY Sp.z o.o. (Poland)
  • www.optex-europe.com/pl
  • OPTEX PINNACLE INDIA,
  • PVT., LTD. (India)
  • www.optexpinnacle.com
  • OPTEX KOREA CO.,LTD. (Korea)
  • www.optexkorea.com
  • OPTEX (DONGGUAN) CO.,LTD.
  • SHANGHAI OFFICE (China)
  • www.optexchina.com
  • OPTEX (Thailand) CO., LTD. (Thailand)
  • www.optex.co.th
  • Copyright (C) 2022 OPTEX CO.,LTD.

Documents / Resources

| OPTEX FLX-S-ST FlipX Series Flexible Range Indoor Detector [pdf] Instruction Manual
FLX-S-ST, FLX-S-DT-X5, FLX-S-DT-X8, FLX-S-DT-X9, FLX-S-ST FlipX Series Flexible Range Indoor Detector, FLX-S-ST, FlipX Series Flexible Range Indoor Detector, Flexible Range Indoor Detector, Range Indoor Detector, Detector
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals