OPTEX AP-360B(C) Indoor Recessed Mount PIR Detector Instruction Manual

June 2, 2024
OPTEX

OPTEX AP-360B(C) Indoor Recessed Mount PIR Detector

Specifications

  • Model : AP-360B(C)
  • Installation : Indoor Recessed Mount
  • Power Supply: 12V DC or 14V DC
  • Mounting Height: 2.5 to 4.5 meters (8’2 to 14’9)
  • Power Cable Length: AWG 22 – 520m (12V DC) or 1,130m (14V DC)

Product Usage Instructions

Settings

  1. Disassemble: Open the base cover to set the detector.
  2. Jumper Pin Settings:
    • JP1 Alarm output mode: N.C. (default) or N.O.
    • JP2 PIR sensitivity: H (recommended), M (default), L
  3. Light Control Mode Settings: Adjust the jumper pin accordingly based on mounting height.
  4. Assemble: Close the base cover and fasten the screw to fix the cover.

Installation

Ceiling Mount Without Switch Box

  1. Install retaining springs on both sides as illustrated.
  2. Insert the detector into the hole with the retaining spring facing up.
  3. Mount the detector on the ceiling, ensuring wires slope downward to prevent water ingress.

Ceiling Mount With 86-Type Box

  1. Prepare an 86-type box on the ceiling aligning with the bump and triangle recess.
  2. Install the detector into the 86-type box.
  3. Fix the detector with screws and cover their heads with caps, ensuring wires slope downward.

Wiring

Wiring details:

  1. Red: Power supply positive
  2. Black: Power supply negative
  3. White: Alarm output
  4. Yellow: Alarm output
  5. Green: Tamper output
  6. Blue: Tamper output

Note: Power cable length should be within the specified limits for optimal performance.

Before installation

Manufacturer’s statement

Symbol

  • Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.
  • Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.

Symbol

  • The check mark indicates a recommendation.
  • Nix’s sign indicates prohibition.
  • Special attention is required to the section of this symbol.

Warning

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-5

Caution

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-6

Parts identifications

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-7

Accessories

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-8

Settings

  1. Disassemble

  2. Jumper pin settings
    JP1
    Alarm output mode
    JP2PIR sensitivityOPTEX-AP-360B\(C\)-Indoor-Recessed-
Mount-PIR-Detector-fig-11****

  3. Light control mode settings

  4. AssembleOPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-fig-13

Installation

  1. Install a retaining spring on both sides. (follow the illustrated arrow steps to complete the assembly of the retaining spring.)OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-fig-15
  2. Make a ø45 mm (1.77”) hole in the ceiling for mounting
  3. Insert the detector into the hole with the retaining spring facing up.
  4. Mount the detector on the ceiling. (Be sure to arrange the wires with a downward slope to prevent water from digging into the detector.)

Ceiling mount with 86-type box

  1. Prepare an 86-type box on the ceiling.
  2. Install the detector into the 86-type box.
  3. Fix the detector with two screws and cover their heads with two caps.

NOTE

Align the bump with the triangle recess as illustrated in the figure.

NOTE

Be sure to arrange the wires with a downward slope to prevent water ingress into the detector.

Wiring

  1. RedPower supply: Positive
  2. Black Power supply: Negative
  3. White Alarm output
  4. Yellow Alarm output
  5. Green Tamper output
  6. Blue Tamper output

Power cable length

The power cable should be limited to the following length. AP-360B(C)

Checking

Walk test

  1. Power on.
  2. Wait for 60 seconds to complete the warm-up time.
  3. Walk in the detection area to check the detecting performance.OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-fig-29
  4. Start operation.

Others

Specifications

Model AP-360B(C)
Detection method Passive infrared
Detection area ø6 m (ø20’) at mounting height 4.5 m (14’9”)
Mounting height 2.5 to 4.5 m (8’2” to 14’9”)
Mounting type Recessed ceiling mount/86-type box mount
Sensitivity 2.0℃ at 0.6 m/s (3.6°F at 2’/s)
Detection speed 0.3 to 3.0 m/s (1’/s to 9’10”/s)


LED indicator

| ****

Warm-up upon power on: blinking Stand-by: off

Alarm: solid on

Alarm cycle| 2 s to 120 s (variable)
Illuminance| 20 to 320 lux (variable/not detected)
Alarm output| N.O./N.C., 28 V DC 200 mA max.


Tamper switch

| N.C. 28 V DC 100 mA max.

The contact opens once the casing is detached.

Warm-up time| Approx. 60 s
Power supply| 9.5 to 16 V DC


Current

| 12 V DC

Stand-by: 11mA, Max.: 13 mA

PIR sensitivity| H/ M/ L
Weight| 50 g (1.76 oz)
Operation temprature| -20 to +50℃ (-4°F to +122°F)
Operation humidity| < 95%
Location| Indoors


Dimensions

| ø52 x 42.5 mm (ø2.05 in. x 1.67 in.): without switch box mount
86 x 86 x 42.5 mm (3.39 x 3.39 x 1.67 in.): with 86-type box mount

  • Specifications and designs are subject to change without prior notice.
  • These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.

Dimensions

Without switch box mount

With 86-type box mount

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-32

Detection area

Top view

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-32

Maximum detection area

Mounting height

| 2.5

(8’ 2’ )

| 3.0

(9’ 10” )

| 3.5

(11’ 6” )

| 4.0

(13’ 1” )

| 4.5

(14’ 9” )

---|---|---|---|---|---

Detection area

| ø3.3 (ø10’ 10” )| ø4.0 (ø13’ 1” )| ø4.6 (ø15’ 1” )| ø5.4 (ø17’ 8” )| ø6.0 (ø20’ )

Side view

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-35

Troubleshooting

OPTEX-AP-360B\(C\)-Indoor-Recessed-Mount-PIR-Detector-
fig-36

Compliance

EU & UK contact information

https://navi.optex.net/cert/contact/

contact

Copyright (C) 2022 OPTEX CO.,LTD.