OPTEX CX-702 Long Range PIR Detector Instruction Manual

June 4, 2024
OPTEX

OPTEX CX-702 Long Range PIR Detector

FEATURES

  • Dual Purpose Lens: Selectable “WIDE ANGLE and “LONG RANGE” detection patterns
  • Double Conductive Shielding of the pyroelectric element Extremely High Light and RFI Immunity (Patent listed)
  • Multifocus Optics Design (Patent listed)
  • LED On / Off Switch
  • Sealed Optics
  • Easy Installation
  • Alarm Memory (CX-702V Only)
  • LED Remote Control Terminal (CX-702V Only)

OPTION

  • CA-1W: Wall Mount Bracket: adjustable t45″ (Horizontally). 0 to 20 (Vertically downwards)
  • CA-2C: Ceiling Bracket: adjustable s45″ (Horizontally). 0 to 20° (Vertically downwards)

INSTALLATION HINTS

  1. Avoid direct sunlight.
  2. Avoid mounting detector where movement of Fans or Air Conditioning Fans can be detected.
  3. Avoid vapor or high humidity that can cause condensation.
  4. Avoid Curtain, Screen, etc. blocking detection area.
  5. Do not install outdoors.
  6. WARNING: Never repair or modify product. It may cause accident, fire hazard or electric shock.
  7. WARNING: When damage has occurred to the product, i.e. water logged, abnormal things inside product, overheating or smoking, strange smells etc., immediately stop using product and contact your supplier. Otherwise, continued use in such condition may cause electric shock or fire hazard.
  8. CAUTION: Mount securely. A falling product may cause injury.
    This symbol indicates prohibition.

DETECTION AREA

DESCRIPTION AND OPERATION

INSTALLATION

  1. Loosen fastening screw and remove cover.

  2. Lead in wires through knockouts along the wiring guide on the rear side of base. Mount base with supplied screws. When using a bracket, check matching knockout position before opening mounting holes. Wire according to Section 5.

  3. Remove the screw fixed the lens holder (CX-702V Only), open the cover’s hook and then lens cover can be removed.

  4. Remove lens holder carefully. Select wide angle or long range according to Section 6-2.
    ( Note: Factory default is WIDE ANGLE.)

  5. Check to confirm that the lens is in the desires position. Press down the lens holder until it clicks into place along the guide of cover. Fix the screw at the end.

  6. Conduct a walk test and make adjustments (Section 7). Fit cover using fastening screw.

WIRING

  • When using two or more units on one wire, the maximum length is obtained by dividing the maximum wire length listed above by the number of units
    used.

  • UL requires CX-702 to be connected to a UL listed power supply capable of providing a nominal input of 12 V DC 11 mA (max.) and battery standby time of 4 hours.

  • For UL Listed systems, do not connect field wiring more than 25 ft. to Alarm Memory, and DL terminals.

  • The equipment shall be installed in accordance accordance with tho National Electrical Coda NEDA 70.

ADJUSTMENTS FOR REQUIRED AREA PATTERN

The CX-702 is designed to provide ideal detection areas for different patterns ranging from 12 m (40 ft.) to 21 m (70 ft.) Wide Angle, and 24 m (80 ft.) to 45 m (150 ft.) Long Range. The following adjustments will provide ideal detection areas for each of these requirements.

  1. DETERMINE THE AREA PATTERN
    Before making adjustments, determine the pattern area, detection range mounting height.

  2. SELECTING WIDE ANGLE OR LONG RANGE DETECTION

  3. Inverting the lens will select either the Wide Angle or Long Range detection patterns.

  4. Please note markings “W (Wide Angle) ” and “L (Long Range) “, on each side of lens.

  5. For Wide Angle, “W” wil be on top of lens

  6. For Long Range, “L” will be on top of lens.

  7. VERTICAL ADJUSTMENT OF DETECTION AREA
    Adjust the vertical angle according to the desired detection range and mounting height.

  8. Set the upper edge of the lens at either the “A”, “B” or “C” position.

  9. The following chat illustrates the different position setting.

  10. Confirm the detection area by conducting a walktest.

FUNCTIONS

CAUTION : Always conduct a walktest after changing the position of this switch to ensure the detector is still providing optimum coverage.

  1. LED ON/ OFF
    Jumper Pin Switch : The Alarm LED indicator can be switched either “ON” or “OFF”.
    D.L. terminal (CX-702V Only)
    LED can be enabled or disabled remotely from control panel by D.L. terminal.

  2. Place Jumper Pin Switch in OFF position.

  3. LED “ON”:
    Connect DL terminal to common ground with detector. (0 to 1 V DC, grounded)
    LED “OFF”:
    No Connection to the DL terminal. (OPEN Or +5 to 16 V DC)

  4. PULSE COUNT
    The Detection Mode can be switched to either “2” or “4” mode depending on the environmental conditions of the installation.
    2:** For normal applications.
    4: For use in hostile areas where there may be movement of small animals or other objects such as fax machines or curtains.
    When the “4” is selected, the detector’s sensitivity may seem sluggish. It is therefore important to always conduct a walktest to ensure that the desired Coverage IS given.
    CAUTION :** Do not use pulse count 4 |for Long Range detection.

  5. ALARM MEMORY ( CX-702V Only )

  6. Alarm Memory
    This function is used to indicate if the detector was activated while the panel was armed. It will cause the red LED on the Detector to illuminate once the panel has been disarmed. Compatible Control Panel is required for Alarm memory. Connect A.M. terminal to Control Panel’s Control Voltage Signal terminal (System Arming status Voltage Output).

  7. Operation
    If the unit triggered during armed period, when the system is disarmed, LED will remain lit to confirm that it reported an alarm.

  8. Alarm Memory will operate even when LED is switched OFF.

  9. Alarm Memory will not operate while system is disarmed.

  10. After Alarm Memory latches, Alarm Output and LED operate normally during armed period.

  11. Reset
    Alarm Memory resets automatically when system is re-armed.
    POSITIVE : Leave AM Jumper as it is.
    NEGATIVE : Cut AM Jumper as shown.

TROUBLESHOOTING

Specifications

Specifications are design are subject to change without prior notice.

Note :

  • This unit is design to detect movement of an intruder and activate an alarm control panel.
  • Being only a part of a complete system , we cannot accept responsibility for any damages or other consequences resulting  from an intrusion.

EU & UK contact information

https://navi.optex.net/cert/contact

OPTEX INc./AMERICAS HQ (U.S.) www.optexamerica.com
OPTEX (EUROPE) LTD.JEMEA HQ (u.K.)www.optex-europe.com
OPTEX SECURITY B.V. (The Netherlands)www.optex-europe.com/nl

OPTEX Co., LTD. (JAPAN) www.optex.net

Read User Manual Online (PDF format)