OPTEX AP-20NBR(C) Indoor Recessed Mount PIR Detector Instruction Manual
- June 1, 2024
- OPTEX
Table of Contents
OPTEX AP-20NBR(C) Indoor Recessed Mount PIR Detector
Specifications
- Model: AP-20NBR(C)
- Mounting Type: Indoor Recessed
- Detection Area: 6.0m (20′) curtain detection area at 4.5m (14′ 9″) mounting height
Product Usage Instructions
Before Installation
Manufacturer’s Statement:
Warning: Failure to follow the provided instructions may cause serious
injury.
Parts Identification
- Top Cover
- Lens
- Base Cover
- JP2 PIR Sensitivity
- JP1 Alarm Output Mode
- SW1 Tamper Switch
- JP3 Battery Saving Timer
Settings
- Disassemble the base cover to set the detector.
- Adjust Jumper Pin settings for Alarm Output Mode, PIR Sensitivity, and Battery Saving Timer.
- Reassemble the base cover securely.
Installation
Ceiling Mount Without Switch Box
- Install retaining springs on both sides as illustrated.
- Insert the detector into the hole ensuring the retaining springs are positioned correctly.
- Arrange wires with a downward slope to prevent water ingress.
Ceiling Mount With 86-Type Box
- Prepare an 86-type box on the ceiling.
- Install the detector into the 86-type box and secure with screws and screw caps.
FAQ
-
What is the recommended mounting height for the detector?
The recommended mounting height is between 2.5m to 4.5m (8’2″ to 14’9″). -
How can I adjust the PIR sensitivity of the detector?
Use Jumper Pin JP2 to adjust the PIR sensitivity to High (H), Medium (M), or Low (L). -
Can the detector be used outdoors?
No, outdoor installation is not recommended as it may lead to performance issues.
Before installation
Manufacturer’ s statement
Parts identifications
Accessories
Settings
- Disassemble
Open the base cover, and to set the detector.
- **Jumper pin settings
**
- Assemble
Close the base cover, and fasten the screw to fix the cover.
Installation
Ceiling mount without switch box
- Install a retaining spring on both sides.
(follow the illustrated arrow steps to complete the assembly of the retaining spring.)
-
Make a ø45 mm (1.77”) hole in the ceiling for mounting.
-
Insert the detector into the hole so that the retaining springs come first.
Ceiling mount with 86-type box
NOTE
For the 86-type box mount, dual 86-type boxes are recommended with the
additional one used to accommodate the transmitter.
- Prepare an 86-type box on the ceiling.
- Install the detector into the 86-type box.
NOTE
Align the bump with the triangle recess as illustrated in the figure.
- Fix the detector with two screws and cover their heads with two caps.
Wiring
Checking
Walk test
-
Power on.
-
Wait for 60 seconds to complete the warm-up time.
-
Walk in the detection area to check the detecting performance.
- Start operation.
OTHER
Specifications
Model | AP-20NBR(C) |
---|---|
Detection method | Passive infrared |
Detection area
| < Ceiling mount >
6.0 m x 1.0 m (20’ x 3’3”)
at 4.5 m (14’9”) height
| < Wall mount >
6.0 m x 4.5 m (20’ x 14’9”)
at 1.5 m (4’11”) height
Mounting height
| 2.5 m to 4.5 m (8’2” to 14’9”)| 1.5 m (4’11”): Horizontal
1.0 m (3’3”): Vertical
Mounting type| Recessed ceiling mount/ Wall mount/ 86-type box mount
Sensitivity| 2.0℃ at 0.6 m/s (3.6°F at 2’/s)
Detection speed| 0.3 to 3.0 m/s (1’/s to 9’10”/s)
LED indicator
| Warm-up upon power on: blinking Stand-by: off
Walk test: solid on
Alarm: off
Alarm cycle| Approx. 2 s
Battery saving timer| 120 s/ 5 s selectable
Alarm output| N.O./N.C., 3.6 V DC 10 mA max.
Tamper switch
| N.C. 28 V DC 100 mA max.
The contact opens once the casing is detached.
Warm-up time| Approx. 60 s
Power supply| 2.7 to 3.6 V DC (CR123A battery)
Current
| 3 V DC
Stand-by: 10цA, Max.: 4 mA
PIR sensitivity| H/ M/ L
Weight| 50 g (1.76 oz)
Operation temprature| -20 to +50℃ (-4°F to +122°F)
Operation humidity| < 95%
Location| Indoors
Dimensions
| ø52 x 35.5 mm (ø2.05 x 1.40 in.): without switch box mount
86 x 86 x 36.5 mm (3.39 x 3.39 x 1.44 in.): with 86-type box mount
- Specifications and designs are subject to change without prior notice.
- These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
Dimensions
Detection area
Timing chart
Troubleshooting
ABOUT COMPANY
-
OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com -
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com -
OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl -
OPTEX SECURITY SAS (France)
www.optex-europe.com/fr -
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex-europe.com/pl -
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
www.optexpinnacle.com -
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com -
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
www.optexchina.com -
OPTEX (Thailand) CO., LTD. (Thailand)
www.optex.co.th
References
- Homepage | Optex Europe
- Homepage | Optex Europe
- Homepage | Optex Europe
- Homepage | Optex Europe
- OPTEX ASEAN | Sensor and system designed in Japan
- OPTEX Global Site
- Leading manufacturer of high performance sensing technologies - Optex America
- 奥泰斯电子(东莞)有限公司-红外对射探测器|双鉴探测器|被动红外探测器|室外探测器|报警系统|联网报警
- Optex - Leading Sensing Technologies Manufacturer
- Contact Information