OPTEX FlipX Series Range Indoor Detector Installation Guide

June 4, 2024
OPTEX

OPTEX FlipX Series Range Indoor Detector Installation Guide
OPTEX FlipX Series Range Indoor Detector

Instructions

| Wide/Narrow area Flip lens| PIR| Microwave| Mounting bracket
---|---|---|---|---
FLX-S-ST| ✓| ✓| –| –
FLX-S-ST-BKT3| ✓| ✓| –| ✓
FLX-S-DT-X5
1| ✓| ✓| ✓ (10.525GHz)| –
FLX-S-DT-X5-BKT3| ✓| ✓| ✓ (10.525GHz)| ✓
FLX-S-DT-X8
2| ✓| ✓| ✓ (10.587GHz)| –
FLX-S-DT-X9*3| ✓| ✓| ✓ (9.425GHz)| –

Before installation

Manufacturer’ s statement

Symbol Meaning
Warning Failure to follow the instructions provided with this indication

and improper handling may cause death or serious injury.
Caution| Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.
Symbol| Check mark indicates recommendation.
| Nix sign indicates prohibition
| Special attention is required to the section of this symbol.

Warning

Warning
Warning Warning
WarningWarning

Caution

Caution
Caution
Caution Caution
Caution

Parts identifications

Parts identifications

Option

CW-G2 *
Bracket for wall/ceiling mount

Models with “-BKT” in the model name include CW-G2.
Parts identifications

Joint screw x 3

Fixing screw x 2

*Not certified to EN 50131-2-2:2017
/EN 50131-2-4:2020, INCERT and SBSC

Installation

Disassemble

  1. Unlock the cover
    Installation

  2. Open the cover
    Installation

  3. Remove the main unit
    Installation

Wall mount without bracket

Wire through the base

Wiring knockouts
Wall mount

How to break the knockouts
Wall mount

  • A. Surface wiring
    Wall mount Wall
mount

  • B. Hidden wiring
    Wall mount

Mount the base

Mounting holes
Wall mount

  • a. Wall mount
    Wall mount

  • b. Corner mount
    Wall mount

Wall mount with bracket

Wire and mount on the wall
Wall mount with bracket

Wall mount with bracket

Mounting screws are not included.
Φ 3 mm screws are recommended.

See page 4 for how to break the knockouts.

Join the base on the bracket
Wall mount with bracket

Fix the base with the fixing screws (optional)
Wall mount with bracket

The bracket is basically jointed using 3 holes and 3 joint screws.
Also use 2 additional fixing screws if stronger support is required.

Adjust the detection direction while jointing.
Confirming with a walk test is required.
–> Refer to “3-1. Walk test”

Ceiling mount with bracket

How to change the bracket to the ceiling mounting

  1. Loosen the fixing screw.
    Ceiling mount with bracket

  2. Rotate the body.
    Ceiling mount with bracket

  3. Tighten the fixing screw
    Ceiling mount with bracket

Wire and mount on the ceiling

Ceiling mount with bracket

See page 4 for how to break the knockouts.

Ceiling mount with bracket

Mounting screws are not included.
Φ 3 mm screws are recommended

Join the base on the bracket

Ceiling mount with bracket

Adjust the detection direction while jointing.
Confirming with a walk test is required.
–> Refer to “3-1. Walk test”

Fix the base with the fixing screws
(optional)

Ceiling mount with bracket
The bracket is basically jointed using 3 holes and 3 joint screws.
Also use 2 additional fixing screws if stronger support is required.

Assemble and connect

Attach the main unit to the base
Assemble and connect Assemble and
connect

Connect wires to the terminal

Assemble and connect

Power cable length
The power cable should be limited to the following length.

FLX-S-ST

WIRE GAUGE 12 V DC 14 V DC

AWG 22

(0.33 mm²)

| 520 m

(1,710 ft.)

| 1,130 m

(3, 718 ft.)

AWG 20.

(0.52 mm²)

AWG 18

(0.83 mm²)

| 820 m

(2,690 ft.)

| 1,790 m

(5,870 ft.)

1,320 m

(4,330 ft.)

| 2,850 m

(9,350 ft.)

FLX-S-DT

WIRE GAUGE 12 V DC 14 V DC

AWG 22

(0.33 mm²)

| 410 m

(1,350 ft.)

| 890 m

(2,920 ft.)

AWG 20

(0.52 mm²)

AWG 18

(0.83 mm²)

| 650 m

(2,130 ft.)

| 1,400 m

(4,590 ft.)

1,030 m

(3,380 ft.)

| 2,240 m

(7,350 ft.)

Settings

Jumper pin settings
Settings

Wide/Narrow setting

Set the Flip lens to “Wide” or “Narrow”
Wide/Narrow setting
Wide/Narrow setting

Install the lens so that the letters on the cover and on the lens match your intention.

Wide/Narrow setting
Wide/Narrow setting

Caution

  • Be careful not to damage the light path of the LED.
  • Also, be careful not to allow the light path to pinch the

Caution

  • Be careful not to damage the lens with a screwdriver.

How to install the lens

Push the lens firmly at 3 points in numerical order.
How to install the lens 

Set the jumper pin to “Wide” or “Narrow”
Set the jumper pin

Caution

  • The jumper pin must be “Narrow” , when the lens is set to “Narrow” .

  • Default setting is “Wide” .

  • When “Narrow” is selected, MW detection will be disabled.

Checking

Walk test

Confirm that the LED pin is “ON” , then close the cover.
Checking

Walk in the detection area to check the detecting performance via LED indication.
Walk test

Return the LED pin to “OFF” after the walk test, if necessary.
Walk test

Conduct a walk test at least once a year.

Lock the cove
Walk test

Specifications

Model FLX-S-ST (-BKT) FLX-S-DT-X5(-BKT)/-X8/-X9

Installation
Detection method| Passive infrared| Passive infrared and Microwave
Coverage| Wide:12 m (40 ft.) 85°/ Narrow:18 m (60 ft.) 5°

( No MW detection at “Narrow” setting )

Detection zones| Wide: 76 zones/ Narrow: 12 zones
Mounting height| 2.0 to 3.0 m (6’7″ to 9’8”)
Alarm period| 2.0 ± 0.5 s
Warm-up period| Approx. 60 s (LED blinks)
LED indicator| Switchable ON/OFF Green: [1] Warm-up    [2] Alarm
Electrical
Power input| 9.5 to 16 V DC UL *
Current draw| 8 mA (normal)
11 mA (max.) at 12 V DC| 11 mA (normal)
14 mA (max.) at 12 V DC
Relay output| Alarm| N.C. 24 V DC 0.1 A max. (Resistive load)
Tamper| N.C. 24 V DC 0.1 A max. (Resistive load)
(Open when the cover is removed.)
Remote LED| | Terminal: open = OFF 0 V = ON
Environmental
Operation temperature| -20℃ to +50℃(-4°F to +122°F)| -20℃ to +45℃(-4°F to +113°F)
Temperature compensation| Digital (SMDA)
Environmental humidity| 95% max.
RF interference| No alarm 10 V/m
Mechanical
Dimension| H: 129.2 x W: 61.5 x D: 50.9 mm (H: 5.09” x W: 2.42” x D: 2.00”)
Weight| Approx. 90 g (3.17 oz)

(with Bracket : Approx. 120 g (4.23 oz))

| Approx. 105g (3.7 oz)

(with Bracket : Approx. 135 g (4.76 oz))

Mounting| Wall, Corner (Indoor)
(with Bracket : Wall, Corner, Ceiling)

  • Specifications and designs are subject to change without prior notice.
  • These units are designed to detect an intruder and activate an alarm control panel.
    Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.

**UL *** Shall be powered via a UL listed burglar alarm class 2 output power limited power supply that has a min standby power of 4 hrs.

Dimensions

Dimensions

Detection area

Wide – Top view –
Detection area

Wide – Side view –
Detection area

Narrow – Top view –
Detection area

Narrow – Side view –
Detection area

  • The dotted line indicates the recommended mounting height.
  • When “Narrow” is selected at the jumper pin, MW detection will be stopped.
  • Narrow area settings are not certified to the following standards.
    EN 50131-2-2:2017 (FLX-S-ST)/EN 50131-2-4:2020 (FLX-S-DT), INCERT and SBSC.

Angle adjustment with bracket CW-G2

Angle adjustment

  • If the detector cover does not reach the ceiling, it can be swung up to +5°.

Angle adjustment

Compliance

RE Directive 2014/53/EU

  • OPTEX declares that FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8, and FLX-S-DT-X9 comply with RE Directive 2014/53/EU.
    Doc documents can be found on our website; www.optex.net

  • Microwave emission Frequency and Power
    FLX-S-DT-X5| 10.525 GHz| 15.78 mW e.i.r.p
    ---|---|---
    FLX-S-DT-X5-BKT| 10.525 GHz| 15.78 mW e.i.r.p
    FLX-S-DT-X8:| 10.587 GHz| 8.93 mW e.i.r.p
    FLX-S-DT-X9:| 9.425 GHz| 14.50 mW e.i.r.p

  • The following list indicates the areas of intended use of the equipment and any known restrictions.
    For countries not included in this list, please consult the responsible Spectrum Management Agency
    10.525 GHz: Belgium, Denmark, Finland, Germany, Greece, Italy, Luxembourg, The Netherlands, Spain, Sweden, Iceland, Norway, Switzerland
    10.587 GHz: Belgium, France, Germany, Ireland, Luxembourg, The Netherlands, United Kingdom
    9.425 GHz: Austria, Czechia, Esthonia, Germany, Slovakia, Turkey, Russia

  • FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8, and FLX-S-DT-X9 also comply with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

  • EN 50131-1 Grades and Environmental Class; Security Grade 2, Environmental Class II
    Applied Standards; EN 50131-2-2:2017 (FLX-S-ST), EN 50131-2-4:2020 (FLX-S-DT-X5 and FLX-S-DT-X8)
    Tested and certified by Telefication

  • larm klass 2, miljö klass II, SSF 1014

  • PD6662:2017

  • UL/c-UL listed (FLX-S-ST and FLX-S-DT-X5)

EU & UK contact information
https://navi.optex.net/cert/contact/

LogoOPTEX CO., LTD. (JAPAN)
www.optex.net

OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com

OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com

OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl

OPTEX SECURITY SAS (France)
www.optex-europe.com/fr

OPTEX SECURITY Sp.z o.o. (Poland)
www.optex-europe.com/pl

OPTEX PINNACLE INDIA, PVT., LTD. (India)
www.optexpinnacle.com

OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com

OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
www.optexchina.com

OPTEX (Thailand) CO., LTD. (Thailand)
www.optex.co.th

Copyright (C) 2022 OPTEX CO.,LTD.

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

OPTEX User Manuals

Related Manuals