OPTEX FlipX Series Range Indoor Detector Installation Guide
- June 4, 2024
- OPTEX
Table of Contents
OPTEX FlipX Series Range Indoor Detector Installation Guide
Instructions
| Wide/Narrow area Flip lens| PIR| Microwave| Mounting
bracket
---|---|---|---|---
FLX-S-ST| ✓| ✓| –| –
FLX-S-ST-BKT3| ✓| ✓| –| ✓
FLX-S-DT-X51| ✓| ✓| ✓ (10.525GHz)| –
FLX-S-DT-X5-BKT3| ✓| ✓| ✓ (10.525GHz)| ✓
FLX-S-DT-X82| ✓| ✓| ✓ (10.587GHz)| –
FLX-S-DT-X9*3| ✓| ✓| ✓ (9.425GHz)| –
Before installation
Manufacturer’ s statement
Symbol | Meaning |
---|---|
Warning | Failure to follow the instructions provided with this indication |
and improper handling may cause death or serious injury.
Caution| Failure to follow the instructions provided with this indication
and improper handling may cause injury and/or property damage.
| Check mark indicates
recommendation.
| Nix sign indicates prohibition
| Special attention is required to the section of this symbol.
Warning
Caution
Parts identifications
Option
CW-G2 *
Bracket for wall/ceiling mount
Models with “-BKT” in the model name include CW-G2.
Joint screw x 3
Fixing screw x 2
*Not certified to EN 50131-2-2:2017
/EN 50131-2-4:2020, INCERT and SBSC
Installation
Disassemble
-
Unlock the cover
-
Open the cover
-
Remove the main unit
Wall mount without bracket
Wire through the base
Wiring knockouts
How to break the knockouts
-
A. Surface wiring
-
B. Hidden wiring
Mount the base
Mounting holes
-
a. Wall mount
-
b. Corner mount
Wall mount with bracket
Wire and mount on the wall
Mounting screws are not included.
Φ 3 mm screws are recommended.
See page 4 for how to break the knockouts.
Join the base on the bracket
Fix the base with the fixing screws (optional)
The bracket is basically jointed using 3 holes and 3 joint screws.
Also use 2 additional fixing screws if stronger support is required.
Adjust the detection direction while jointing.
Confirming with a walk test is required.
–> Refer to “3-1. Walk test”
Ceiling mount with bracket
How to change the bracket to the ceiling mounting
-
Loosen the fixing screw.
-
Rotate the body.
-
Tighten the fixing screw
Wire and mount on the ceiling
See page 4 for how to break the knockouts.
Mounting screws are not included.
Φ 3 mm screws are recommended
Join the base on the bracket
Adjust the detection direction while jointing.
Confirming with a walk test is required.
–> Refer to “3-1. Walk test”
Fix the base with the fixing screws
(optional)
The bracket is basically jointed using 3 holes and 3 joint screws.
Also use 2 additional fixing screws if stronger support is required.
Assemble and connect
Attach the main unit to the base
Connect wires to the terminal
Power cable length
The power cable should be limited to the following length.
FLX-S-ST
WIRE GAUGE | 12 V DC | 14 V DC |
---|
AWG 22
(0.33 mm²)
| 520 m
(1,710 ft.)
| 1,130 m
(3, 718 ft.)
AWG 20.
(0.52 mm²)
AWG 18
(0.83 mm²)
| 820 m
(2,690 ft.)
| 1,790 m
(5,870 ft.)
1,320 m
(4,330 ft.)
| 2,850 m
(9,350 ft.)
FLX-S-DT
WIRE GAUGE | 12 V DC | 14 V DC |
---|
AWG 22
(0.33 mm²)
| 410 m
(1,350 ft.)
| 890 m
(2,920 ft.)
AWG 20
(0.52 mm²)
AWG 18
(0.83 mm²)
| 650 m
(2,130 ft.)
| 1,400 m
(4,590 ft.)
1,030 m
(3,380 ft.)
| 2,240 m
(7,350 ft.)
Settings
Jumper pin settings
Wide/Narrow setting
Set the Flip lens to “Wide” or “Narrow”
Install the lens so that the letters on the cover and on the lens match your intention.
Wide/Narrow setting
Caution
- Be careful not to damage the light path of the LED.
- Also, be careful not to allow the light path to pinch the
Caution
- Be careful not to damage the lens with a screwdriver.
How to install the lens
Push the lens firmly at 3 points in numerical order.
Set the jumper pin to “Wide” or “Narrow”
Caution
-
The jumper pin must be “Narrow” , when the lens is set to “Narrow” .
-
Default setting is “Wide” .
-
When “Narrow” is selected, MW detection will be disabled.
Checking
Walk test
Confirm that the LED pin is “ON” , then close the cover.
Walk in the detection area to check the detecting performance via LED
indication.
Return the LED pin to “OFF” after the walk test, if necessary.
Conduct a walk test at least once a year.
Lock the cove
Specifications
Model | FLX-S-ST (-BKT) | FLX-S-DT-X5(-BKT)/-X8/-X9 |
---|
Installation
Detection method| Passive infrared| Passive infrared and Microwave
Coverage| Wide:12 m (40 ft.) 85°/ Narrow:18 m (60 ft.) 5°
( No MW detection at “Narrow” setting )
Detection zones| Wide: 76 zones/ Narrow: 12 zones
Mounting height| 2.0 to 3.0 m (6’7″ to 9’8”)
Alarm period| 2.0 ± 0.5 s
Warm-up period| Approx. 60 s (LED blinks)
LED indicator| Switchable ON/OFF Green: [1] Warm-up [2] Alarm
Electrical
Power input| 9.5 to 16 V DC UL *
Current draw| 8 mA (normal)
11 mA (max.) at 12 V DC| 11 mA (normal)
14 mA (max.) at 12 V DC
Relay output| Alarm| N.C. 24 V DC 0.1 A max. (Resistive load)
Tamper| N.C. 24 V DC 0.1 A max. (Resistive load)
(Open when the cover is removed.)
Remote LED| | Terminal: open = OFF 0 V = ON
Environmental
Operation temperature| -20℃ to +50℃(-4°F to +122°F)| -20℃ to +45℃(-4°F to
+113°F)
Temperature compensation| Digital (SMDA)
Environmental humidity| 95% max.
RF interference| No alarm 10 V/m
Mechanical
Dimension| H: 129.2 x W: 61.5 x D: 50.9 mm (H: 5.09” x W: 2.42” x D:
2.00”)
Weight| Approx. 90 g (3.17 oz)
(with Bracket : Approx. 120 g (4.23 oz))
| Approx. 105g (3.7 oz)
(with Bracket : Approx. 135 g (4.76 oz))
Mounting| Wall, Corner (Indoor)
(with Bracket : Wall, Corner, Ceiling)
- Specifications and designs are subject to change without prior notice.
- These units are designed to detect an intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
**UL *** Shall be powered via a UL listed burglar alarm class 2 output power limited power supply that has a min standby power of 4 hrs.
Dimensions
Detection area
Wide – Top view –
Wide – Side view –
Narrow – Top view –
Narrow – Side view –
- The dotted line indicates the recommended mounting height.
- When “Narrow” is selected at the jumper pin, MW detection will be stopped.
- Narrow area settings are not certified to the following standards.
EN 50131-2-2:2017 (FLX-S-ST)/EN 50131-2-4:2020 (FLX-S-DT), INCERT and SBSC.
Angle adjustment with bracket CW-G2
- If the detector cover does not reach the ceiling, it can be swung up to +5°.
Compliance
RE Directive 2014/53/EU
-
OPTEX declares that FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8, and FLX-S-DT-X9 comply with RE Directive 2014/53/EU.
Doc documents can be found on our website; www.optex.net -
Microwave emission Frequency and Power
FLX-S-DT-X5| 10.525 GHz| 15.78 mW e.i.r.p
---|---|---
FLX-S-DT-X5-BKT| 10.525 GHz| 15.78 mW e.i.r.p
FLX-S-DT-X8:| 10.587 GHz| 8.93 mW e.i.r.p
FLX-S-DT-X9:| 9.425 GHz| 14.50 mW e.i.r.p -
The following list indicates the areas of intended use of the equipment and any known restrictions.
For countries not included in this list, please consult the responsible Spectrum Management Agency
10.525 GHz: Belgium, Denmark, Finland, Germany, Greece, Italy, Luxembourg, The Netherlands, Spain, Sweden, Iceland, Norway, Switzerland
10.587 GHz: Belgium, France, Germany, Ireland, Luxembourg, The Netherlands, United Kingdom
9.425 GHz: Austria, Czechia, Esthonia, Germany, Slovakia, Turkey, Russia -
FLX-S-DT-X5, FLX-S-DT-X5-BKT, FLX-S-DT-X8, and FLX-S-DT-X9 also comply with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
-
EN 50131-1 Grades and Environmental Class; Security Grade 2, Environmental Class II
Applied Standards; EN 50131-2-2:2017 (FLX-S-ST), EN 50131-2-4:2020 (FLX-S-DT-X5 and FLX-S-DT-X8)
Tested and certified by Telefication -
larm klass 2, miljö klass II, SSF 1014
-
PD6662:2017
-
UL/c-UL listed (FLX-S-ST and FLX-S-DT-X5)
EU & UK contact information
https://navi.optex.net/cert/contact/
OPTEX CO., LTD. (JAPAN)
www.optex.net
OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl
OPTEX SECURITY SAS (France)
www.optex-europe.com/fr
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex-europe.com/pl
OPTEX PINNACLE INDIA, PVT., LTD. (India)
www.optexpinnacle.com
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
www.optex.co.th
Copyright (C) 2022 OPTEX CO.,LTD.
References
- Homepage | Optex Europe
- Homepage | Optex Europe
- Homepage | Optex Europe
- Homepage | Optex Europe
- OPTEX ASEAN | Sensor and system designed in Japan
- OPTEX Global Site
- Leading manufacturer of high performance sensing technologies - Optex America
- 奥泰斯电子(东莞)有限公司-红外对射探测器|双鉴探测器|被动红外探测器|室外探测器|报警系统|联网报警
- Optex - Leading Sensing Technologies Manufacturer
- Contact Information
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>