T17e Server Installation
Guide
Document Version 1.0
Oct. 2019
© Copyright Bitmaintech Pte. Ltd. 2007 – 2019. All rights reserved.
Bitmaintech Pte. Ltd. (Bitmain) reserves the right to make corrections,
modifications, enhancements, improvements, and other changes to its products
and services at any time and to discontinue any product or service without
notice.
Customers should obtain the latest relevant information before placing orders
and should verify that such information is current and complete. All products
are sold subject to Bitmain’s terms and conditions of sale supplied at the
time of order acknowledgment.
Bitmain warrants the performance of its products to the specifications
applicable at the time of sale in accordance with Bitmain’s standard warranty.
Testing and other quality control techniques are used to the extent Bitmain
deems necessary to support this warranty. Except where mandated by government
requirements, testing of all parameters of each product is not necessarily
performed.
Bitmain assumes no liability for third-party applications assistance.
Customers are responsible for their products and applications using Bitmain
components. To minimize the risks associated with customer products and
applications, customers should provide adequate design and operating
safeguards.
Bitmain does not warrant or represent that any license, either express or
implied, is granted under any Bitmain patent right, copyright, or other
Bitmain intellectual property right relating to any combination, machine, or
process in which Bitmain products or services are used. Information published
by Bitmain regarding third-party products or services does not constitute a
license from Bitmain to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a
third party under the patents or other intellectual property of the third
party, or a license from Bitmain under the patents or other intellectual
property of Bitmain.
Resale of Bitmain products or services with statements different from or
beyond the parameters stated by Bitmain for that product or service voids all
express and any implied warranties for the associated Bitmain product or
service and is an unfair and deceptive business practice. Bitmain is not
responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered
trademarks of their respective holders.
All text and figures included in this publication are the exclusive property
of Bitmaintech Pte. Ltd. (Bitmain), and may not be copied, reproduced, or used
in any way without the express written permission of Bitmain. Information in
this document is subject to change without notice and does not represent a
commitment on the part of Bitmain. Although the information in this document
has been carefully reviewed, Bitmain does not warrant it to be free of errors
or omissions. Bitmain reserves the right to make corrections, updates,
revisions, or changes to the information in this document.
Overview
The T17e server is Bitmain’s newest version in the 17e server series. Power supply APW9+ is part of the T17e server. All T17e servers are tested and configured prior to shipping to ensure easy setup.
|
---|---
Front View| Back View
Caution:
- The equipment must be connected to an earthed main socket outlet. The socket outlet shall be installed near the equipment and shall be easily accessible.
- The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
- Please refer to the layout above to place your goods in usage in case of any damage.
- DO NOT remove any screws and cables tied to the product.
- DO NOT PRESS the metal button on the cover.
T17e Server Components
The main components and controller front panel of T17e servers are shown in the following figure:
APW9+ Power Supply:
Note:
- Power supply APW9+ is part of the T17e server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed.
Specifications
Product Glance
|
Value
---|---
Version Model No. Crypto Algorithm/Coins| T17e 256-Aa SHA256/BTC/BCH
Hashrate. TH/s| 53.00
Reference power efficiency on wall @25°C, .3/TH| 55.00+10%
Detailed Characteristics| Value
---|---
Min| Typ| Max
Hardware Configuration
Miner Size (LengthsWidthHeight. w/o package). film’s.“| 298.0175.0.304.0
Net weight. kg”'”| 9.50
Notes:
(1-1) Including PSU size
(1-2) Including PSU weight
Setting Up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
-
Go to the following site:
https://shop.bitmain.com/support.htm?pid=00720160906053730999PVD2K0vz0693 -
Download the following file: IPReporter.zip.
-
Extract the file.
The default DHCP network protocol distributes IP addresses automatically. -
Right-click IPReporter.exe and run it as Administrator.
-
Select one of the following options:
■ Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
■ Default – suitable for home servers. -
Click Start.
7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).
The IP address will be displayed in a window on your computer screen.
8. In your web browser, enter the IP address provided.
9. Proceed to login using root for both the username and password.
10. In the Network section, you can assign a DHCP IP address (optional).
11. Click Save & Apply.
3. Configuring the Server Setting Up the Pool
To configure the server:
1. click General Settings.
2. Set the options according to the following table:
Option | Description |
---|---|
Pool URL | Enter the URL of your desired pool. |
The T17e servers can be set up with three mining pools, with decreasing
priority from the first pool (pool 1) to the third pool (pool 3). The pools
with low priority will only be used if all higher priority pools are offline.
Worker| Your worker ID on the selected pool.
Password| The password for your selected worker.
3. Click Save & Apply to save and restart the server.
4. Monitoring Your server
To check the operating status of your server:
1. Click the status marked below.
Note: The T17e server is with automatic frequency. The firmware will stop running when the Temp (PCB) reaches 80℃ or Temp(chips) reaches 95℃, there will be an error message “Fatal Error: Temperature is too high!” shown at the bottom of the kernel log page.
2. Monitor your server according to the descriptions in the following table:
O ption Description
ASIC#| A number of chips were detected in the chain.
Frequency| ASIC frequency setting.
GH/S(RT)| Hash rate of each hash board (GH/s).
Temp(PCB)| The temperature of each hash board (°C). (Applied only to the
server with fixed frequency).
Temp(Chip)| The temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:
- 0 – indicates OK
- X – indicates an error
- – – indicates dead
Administering Your Server
5.1 Checking Your Firmware Version To check your firmware version:
1. In System, click the Overview tab.
2. File System Version displays the date of the firmware your server uses. In
the examples below, the servers are respectively using firmware version
20191023.
Upgrading Your System
Make sure that the T17e server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
To upgrade the server’s firmware:
1. In the System, click Upgrade.
2. For Keep Settings:
■ Select the check box to keep your current settings (default).
■ Clear the check box to reset the server to default settings.
3. Click the (Browse) button and navigate to the upgrade file. Select the
upgrade file, then click Flash image. A message appears notifying you if the
T17e firmware can be upgraded and if yes, will then proceed to flash the
image.
4. When the upgrade is completed, the following message appears:
5. Click one of the following options:
■ Reboot – to restart the server with the new firmware.
■ Go Back – to continue mining with the current firmware. The server will load
the new firmware next time when it is restarted.
Modifying Your Password
To change your login password:
1. In System, click the Administration tab.
2. Set your new password, then click Save & Apply.
Restoring Initial Settings
To restore your initial settings
1. Turn on the server and let it run for 5 minutes.
2. On the controller front panel, press and hold the Reset button for 10
seconds.
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Environmental Requirements
Please run your server in accordance with the following requirements
1. Basic Environmental Requirements:
1.1. Climatic Conditions:
Description | Requirement |
---|---|
Operating Temperature | 0-40℃ |
Operating Humidity | 10-90%RH (non-condensing) |
Storage Temperature | -20-70℃ |
Storage Humidity | 5-95%RH(non-condensing) |
Altitude | <2000m |
1.2. Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources:
For heavy pollution sources such as smelters and coal mines, the distance
should be more than 5km. For moderate pollution sources such as chemical
industries, rubber, and electroplating industries, the distance should be more
than 3.7km. For light pollution sources such as food factories and leather
processing factories, the distance should be more than 2km. If unavoidable,
the site should be chosen in the perennial upwind direction of the pollution
source. Please do not set your location within 3.7km from the seaside or the
salt lake. If unavoidable, it should be built as airtight as possible,
equipped with air conditioning for cooling.
1.3. Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables,
transmission lines, and high-current equipment, for example, there should be
no high-power AC transformers (>10KA) within 20 meters, and no high-voltage
power lines within 50 meters. Please keep your site away from high-power radio
transmitters, for example, there should be no high-power radio transmitters
(>1500W) within 100 meters.
2. Other Environmental Requirements:
The server running room shall be free of explosive, conductive, magnetically
conductive, and corrosive dust. The requirements of mechanical active
substances are shown below:
2.1 Requirements of Mechanical Active Substances
Mechanical Active Substance | Requirement |
---|---|
Sand | <= 30mg/m³ |
Dust (suspended) | <= 0.2mg/m³ |
Dust (deposited) | <=1.5mg/m²h |
2.2 Requirements of Corrosive Gas
Corrosive Gas | Unit | Concentration |
---|---|---|
H2S | ppb | < 3 |
SO2 | ppb | < 10 |
Cl2 | ppb | < 1 |
NO2 | ppb | < 50 |
HF | ppb | < 1 |
NH3 | ppb | < 500 |
O³ | ppb | < 2 |
Regulations:
**FCC Notice (FOR FCC CERTIFIED MODELS):
**
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service, or the shop where you purchased the product.
Bitmaintech Pte.Ltd.
Tel:+86-400-890-8855
www.bitmain.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>