BITMAIN AntMiner Z11 Bitcoin Miner Installation Guide

June 6, 2024
BITMAIN

BITMAIN logo

BITMAIN AntMiner Z11 Bitcoin Miner

BITMAIN AntMiner Z11 Bitcoin Miner

© Copyright Bitmaintech Pte.Ltd. 2007 – 2019. All rights reserved.
Bitmaintech Pte.Ltd. (Bitmain) reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.

Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain’s terms and conditions of sale supplied at the time of order acknowledgment.

Bitmain warrants performance of its products to the specifications applicable at the time of sale in accordance with Bitmain’s standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.

Bitmain assumes no liability for third‐party applications assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.

Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used. Information published by Bitmain regarding third‐party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain.

Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered trademarks of their respective holders.

All text and figures included in this publication are the exclusive property of Bitmaintech Pte.Ltd.(Bitmain), and may not be copied, reproduced, or used in any way without the express written permission of Bitmain. Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain. Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be free oferr or so ro missions. Bitmain reserves the right to make corrections, updates, revisions or changes to the information in this document.

Bitmaintech Pte.Ltd.
Tel:+86‐400‐890‐8855
www.bitmain.com

Overview

The Z11 server is Bitmain’s newest version in the Z11 server series. All Z11 servers are tested and configured prior to shipping to ensure easy set up.

Overview

Overview 1

Z11 Server Components

The Z11 server main components and controller front panel are shown in the following figure:

Z11 Server Components

Connecting the Power Supply
  1. Press down on the button at the direction indicated by arrow A, and slide the upper cover of the control board along the direction indicated by arrow B after the button is pressed in place.Connecting the Power Supply
  2. The position and name of the socket after sliding the upper cover of the control board are as shown below.Connecting the Power Supply 1
  3. Connect the power supply to the corresponding socket of the server, then tie the cables at the position indicated by arrow C and place all the cables into the U‐shaped hole.Connecting the Power Supply 2
  4. Push the upper cover of the main control board back into place and ensure that the button indicated by arrow A is stuck in place.
Specifications

Model No.: 240‐Z
Version: Z11

Product Glance Value
Model No. 240‐Z
Crypto Algorithm/Coins EquiHash/Zcash
Hashrate, KSol/s 135
Reference power on wall, Watt 1418
Reference power efficiency on wall @25°C, J/Ksol 10.50
Adapted AC/DC output requirement, Watt/ Volt 1729/ 12.00
Detailed Characteristics Value
Min Typ

Hashrate & Power
Hashrate, KSol/s|  | 135| 142
Power efficiency on wall @25°C, J/KSol(1‐1)| 10.50|  | 11.24
Power efficiency on wall @40°C, J/KSol(1‐2)| 11.01|  | 11.78
Reference power on wall, Watt (1‐3)| 1418|  | 1673
DC input voltage range, Volt (1‐4)| 11.60| 12.00| 13.00
DC input current range, Amp (1‐5)|  | 109.90| 134.13
---|---|---|---
Adapted AC/DC output power requirement, Watt (1‐6)| 1556| 1729|
Hardware Configuration
Quantity of hash chips| 9
Quantity of hash boards| 3
Networking connection mode| RJ45 ethernet 10/100M
Miner    Size    (LengthWidthHeight,     w/o package), mm (2‐1)| 242134302
Net weight, kg (2‐2)| 5.40
Noise, dBA @25°C (3‐1)|  |  | 70
Environment Requirements
Operation temperature,°C| 0| 25| 40
Storage temperature,°C| ‐40| 25| 85
Operation humidity, RH| 5%|  | 95%

Notes:

  1. Refers PSU power conversion efficiency of 93%

  2. Refers PSU power conversion efficiency of 93%

  3. Min condition: 25°C, min J/KSol, typical hashrate
    Max condition: 40°C, max J/KSol, max hashrate
    Refers PSU power conversion efficiency of 93%

  4. Caution: Wrong input voltage may probably cause miner damaged

  5. Typ condition: min reference power, typical DC input voltage
    Max condition: max reference power, min DC input voltage

  6. Min condition: 40°C, max J/KSol, max hashrate,
    PSU output power should be no less than the min value to make sure mining stable.
    Typical condition: ( typical power) = (min power)/90%, leave power output margin for PSU.
    Caution: It is strongly recommended that using typical power can make sure your miner work well.
    You can use one PSU to power multiple boards. Do not attempt to power one board with more than one PSU.
    All PCI‐E ports are required to plug in while powering up the board.

  7. domestic and international version

  8. domestic and international version

  9. Max condition: Fan is under max RPM(rotation per minute).

Setting Up the Server

To set up the server:
NOTE: The file IPReporter.zip is supported by Microsoft Windows only.

  1. Go to the following site:
    https://shop.bitmain.com/support.htm?pid=00720160906053730999PVD2K0vz0693

  2. Download the following file: IPReporter.zip

  3. Extract the file.
    NOTE: The default DHCP network protocol distributes IP addresses automatically.

  4. Right‐click IPReporter.exe and run it as Administrator.

  5. Select one of the following options:

    • Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
    • Default – suitable for home servers.
  6. Click Start.Setting Up the Server

  7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).Setting Up the Server 1The IP address will be displayed in a window on your computer screen.Setting Up the Server 2

  8. In your web browser, enter the IP address provided.

  9. Proceed to login using root for both the username and password.

  10. In the Network section, you can assign a DHCP IP address (optional).

  11. Click Save & Apply.

Setting Up the Server 3

Configuring the Server

Setting Up the Pool

To configure the server:

  1. click General Settings.Configuring the Server
  2. Set the options according to the following table:
    Option| Description
    ---|---
    Pool URL| Enter the URL of your desired pool.

The Z11 server can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).

The pools with low priority will only be used if all higher priority pools are offline.

Worker| Your worker ID on the selected pool.
Password| The password for your selected worker.
3. Click Save & Apply to save and restart the server.

Monitoring Your server

To check the operating status of your server:

  1. Click the status marked below.Monitoring Your server
  2. monitor your server according to the descriptions in the following table:
Option Description
ASIC# Number of chips detected in the chain.
Frequency ASIC frequency setting.
GH/S(RT) Hash rate of each hash board ( GH/s)
Temp(PCB) Temperature of each hash board (°C).(Applied only to server with

fixed frequency)
Temp(Chip)| Temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:

●        O ‐ indicates OK

●        X ‐ indicates error

●        ‐ indicates dead

Administering Your Server

Checking Your Firmware Version
To check your firmware version:

1. In System, click the Overview tab.
2. File System Version displays the date of the firmware your server use. In the example below, the server is using firmware version 20190305.

Administering Your Server

Upgrading Your System
Make sure that the Z11 server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.

To upgrade the server’s firmware:

  1. In System, click Upgrade.Administering Your Server 1
  2. For Keep Settings:
    • Select the check box to keep your current settings (default).
    • Clear the check box to reset the server to default settings.
  3. Click the (Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash image. A message appears notifying you if the Z11 firmware can be upgraded and if yes, will then proceed to flash the image.
  4. When the upgrade is completed, the following message appears:Administering Your Server 2
  5. Click one of the following options:
    • Reboot ‐ to restart the server with the new firmware.
    • Go Back ‐ to continue mining with the current firmware. The server will load the new firmware next time it is restarted.

Modifying Your Password
To change your login password:

  1. In System, click the Administration tab.
  2. Set your new password, then click Save & Apply.

Administering Your Server 3

Restoring Initial Settings
To restore your initial settings

  1. Turn on the server and let it run for 5 minutes.
  2. On the controller front panel, press and hold the Reset button for 10 seconds.
    Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.

FCC Notice (FOR FCC CERTIFIED MODELS)

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where your purchased the product.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals