BITMAIN AntMiner X3 CryptoNight ASIC Miner Installation Guide

June 6, 2024
BITMAIN

BITMAIN AntMiner X3 CryptoNight ASIC Miner Installation Guide

BITMAIN AntMiner X3 CryptoNight ASIC Miner.png

© Copyright Bitmaintech Pte.Ltd. 2007 – 2018. All rights reserved.
Bitmaintech Pte.Ltd. (Bitmain) reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.

Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain’s terms and conditions of sale supplied at the time of order acknowledgment.

Bitmain warrants performance of its products to the specifications applicable at the time of sale in accordance with Bitmain’s standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.

Bitmain assumes no liability for third‐party applications assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.

Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used. Information published by Bitmain regarding third‐party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain.

Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements.

All company and brand products and service names are trademarks or registered trademarks of their respective holders.

All text and figures included in this publication are the exclusive property of Bitmaintech Pte.Ltd. (Bitmain), and may not be copied, reproduced, or used in any way without the express written permission of Bitmain. Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain. Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be free of errors or omissions. Bitmain reserves the right to make corrections, updates, revisions or changes to the information in this document.

Bitmaintech Pte.Ltd.
Tel: +86‐400‐890‐8855
www.bitmain.com

1. Overview

The X3 server is Bitmain’s newest version in the X3 server series. It boasts a state‐of‐the‐art BM1700 custom‐made chip. All X3 servers are tested and configured prior to shipping to ensure easy set up.

FIG 1 Overview.jpg

FIG 2 Overview.jpg

You must provide your own ATX power supply.

1.1 X3 Server Components
The X3 server main components and controller front panel are shown in the following figure:

FIG 3 Server Components.JPG

FIG 4 Server Components.JPG

1.2 Specifications

FIG 5 Specifications.JPG

FIG 6 Specifications

2. Connecting the Power Supply

Ten PCI‐e connectors are located at the top of the X3 server for connecting the PSU as follows:

  • Nine PCI‐e connectors for the hash boards. Each hash board has a set of three PCI‐e connectors.
  • One PCI‐e connector located on the controller.

Each hashboard must be powered by the same PSU to prevent possible damage and instability.

To connect the power supply:

  1. Connect PSU power cable connectors to each of the nine PCI‐e connectors on the top of the X3 server, ensuring that each hash board is powered by the same PSU.

FIG 7 To connect the power supply.jpg

2. Connect a PSU power cable connector to the X3 PCI‐e connector on the controller.
3. Connect the network cable to the ETH port.
4. To power up your X3 server, connect the PSUs to the power wall outlet.

If you are using more than one PSU,power up the PSU connected to the controller AFTER you have Powered up the other PSU(s).

3. Setting Up the Server

To set up the server:

The file IPReporter.zip is supported by Microsoft Windows only.

  1. Go to the following site:
    https://shop.bitmain.com/support.htm?pid=00720160906053730999PVD2K0vz0693

  2. Download the following file: IPReporter.zip

  3. Extract the file.
    The default DHCP network protocol distributes IP addresses automatically.

  4. Right‐click IPReporter.exe and run it as Administrator.

  5. Select one of the following options:
    ■ Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
    ■ Default – suitable for home servers.

  6. Click Start.                                                                              FIG 8 Setting Up the Server.jpg

  7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).

FIG 9 Setting Up the Server.jpg

The IP address will be displayed in a window on your computer screen.

FIG 10 Setting Up the Server.jpg

8. In your web browser, enter the IP address provided.
9. Proceed to login using root for both the username and password.
10. In the Network section, you can assign a Static IP address (optional).
11. Click Save & Apply.

FIG 11 Setting Up the Server.jpg

4. Configuring the Server

Setting Up the Pool
To configure the server:

  1. Click General Settings.
  2. Set the options according to the following table:                  FIG 12 Configuring the Server.JPG
  3. Click Save & Apply to save and restart the server.

FIG 13 Configuring the Server.JPG

FIG 14 Configuring the Server.JPG

5. Monitoring Your Server

To check the operating status of your server:

  1. Click the status marked below.
  2. Monitor your server according to the descriptions in the following table:

FIG 15 Monitoring Your Server.JPG

FIG 16 Monitoring Your Server.JPG

FIG 17 Monitoring Your Server.JPG

6. Administering Your Server

6.1 Checking Your Firmware Version

To check your firmware version:

  1. In System, click the Overview tab.
  2. File System Version displays the date of the firmware your server use. In the example below, the server is using firmware version 20180411.

FIG 18 Checking Your Firmware Version.jpg

6.2 Upgrading Your System

Make sure that the X3 server remains powered during the upgrade process. If power fails before
the upgrade is completed, you will need to return it to Bitmain for repair.

To upgrade the server’s firmware:

  1. In System, click Upgrade.                                                        FIG 19 upgrade the server’s firmware.jpg

  2. For Keep Settings:
    ■ Select the check box to keep your current settings (default).
    ■ Clear the check box to reset the server to default settings.

  3. Click the (Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash image. A message appears notifying you if the X3 server firmware can be upgraded and if yes, will then proceed to flash the image.

  4. When the upgrade is completed, the following message appears:  FIG 20 upgrade the server’s firmware.jpg

  5. Click one of the following options:
    ■ Reboot ‐ to restart the server with the new firmware.
    ■ Go Back ‐ to continue mining with the current firmware. The server will load the new firmware next time it is restarted.

6.3 Modifying Your Password
To change your login password:

  1. In System, click the Administration tab.
  2. Set your new password, then click Save & Apply.

FIG 21 Modifying Your Password.jpg

6.4 Restoring Initial Settings
To restore your initial settings

  1. Turn on the server and let it run for 5 minutes.
  2. On the controller front panel, press and hold the Reset button for 10 seconds.

Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.

Regulation:

FCC Notice (FOR FCC CERTIFIED MODELS):

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where your purchased the product.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals