SALTO LA1T07xx/LA1T17xx/LA1T37xx mortise locks for Ælement

ANSI handing code

Hand changing

Adjust bevel

Installation

PREPARING THE DOOR

  1. Draw a horizontal line on edge of the door and on inside at the desired height of handle above floor.

  2. Draw a vertical centre line on door edge.

  3. Draw a vertical line on inside at the proper backset to align the template.

  4. Mark ONLY top and bottom holes of mortise cavity (A).
    Place lock face against door edge. Trace outline of faceplate as guide for faceplate routing.

  5. Mortise door for lock body and faceplate.

  6. Mark holes in the lateral face of the door for turnpiece (B) and handles (C and D). Mark the holes for the corresponding electronic escutcheon fixings.
    NOTE: See 3-4 pages for reader fixing holes depending on Ælement model.

INSTALLING THE LOCK BODY

  1. Insert wires through hole.
  2. Insert the lock into the cavity.
  3. Mark & drill mortise lock’s fixing holes.
    Fasten backplate and front plate with screws to hold lock in place.

INSTALLING THE STRIKE

  1. Center strike to lock’s frontplate center line.
    Refer to latch to determine strike location on jamb.
    Using strike as template, mark and chisel recess.

  2. Drill holes for dust box. Place dust box and strike and fasten screws.
    Please check that:
    • Deadbolt and latch fit the cavities of the strike without touching it.
    Gap between door and jamb is between 3/32” and7/32”

Maintenance

All locks come from factory pre-lubricated with grease. We rrecommend, however, continued periodic lubrication of moving parts with commercial quality grease (every 20000 cycles or once a year), from outside the lock. This can prolong the life of the lockset by reducing excessive wear. If the lockset is used in a harsh environment, lubrication should be applied more frequently.

DOOR PREPARATION

Only apply for LA1T07xx and LA1T17xx models locks:

| SALTO SYSTEMS, S.L.
Pol. Indust. Lanbarren, c/Arkotz, 9
20180, Oiartzun-Gipuzkoa. Spain
---|---
2812-CPR-NA5003
17| LA1T07 / LA1T17
Electromechanical lock for fire doors
EN 14846:2008| – S8D— —

All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials.
221373-ED.2-10/09/2020

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SALTO User Manuals

Related Manuals