BITMAIN L7 Server Antminer Powerful Crypto Miner Installation Guide
- June 6, 2024
- BITMAIN
Table of Contents
BITMAIN L7 Server Antminer Powerful Crypto Miner Installation Guide
© Copyright Bitmain 2007 2022. All rights reserved.
Bitmain reserves the right to make corrections, modifications, enhancements,
improvements, and other changes to its products and services at any time and
to discontinue any product or service without notice. Customers should obtain
the latest relevant information before placing orders and should verify that
such information is current and complete. All products are sold subject to
Bitmain’s terms and conditions of sale supplied at the time of order
acknowledgment.
Bitmain warrants performance of its products to the specifications applicable at the time of sale in accordance with Bitmain’s standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Bitmain assumes no liability for third-party applications assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.
Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used. Information published by Bitmain regarding third-party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain.
Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered
trademarks of their respective holders.
All text and figures included in this publication are the exclusive property
of Bitmain, and may not be copied, reproduced, or used in any way without the
express written permission of Bitmain. Information in this document is subject
to change without notice and does not represent a commitment on the part of
Bitmain. Although the information in this document has been carefully
reviewed, Bitmain does not warrant it to be free of errors or omissions.
Bitmain reserves the right to make corrections, updates, revisions or changes
to the information in this document.
Bitmain Tel: +86-400-890-8855 www.bitmain.com
1. Overview
The L7 server is Bitmain’s newest version in the current series. Power supply APW121417 is part of L7 server. All L7 servers are tested and configured prior to shipping to ensure easy set up.
Caution:
- Please refer to the layout above to place your goods in usage in case of any damage.
- The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
- The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
- DO NOT remove any screws and cables tied on the product.
- DO NOT PRESS the metal button on the cover.
- Please note that the actual server shall prevail.
1.1 L7 Server Components
The main components and controller front panel of L7 servers are shown in the following figure:
APW121417 Power Supply:
Note:
- Power supply APW121417 is part of L7 server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed.
1.2 Specifications
Version: L7 Model No.: 240-L
Notes:
(1-1) Caution: Wrong input voltage may probably cause server damaged
(1-2) Max condition: temperature 40°C, altitude 0m
(1-3) Two AC input wires, 10A per wire
(2-1) Including PSU size
(2-2) Including PSU weight
(3-1) When the server is used at an altitude from 900m to 2000m, the highest
operating temperature decreases by 1℃ for every increase of 300m
2. Setting up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
-
Go to the following site: https://shop.bitmain.com/support.htm?pid=00720160906053730999PVD2K0vz0693
-
Download the following file: IPReporter.zip.
-
Extract the file.
The default DHCP network protocol distributes IP addresses automatically. -
Right-click IPReporter.exe and run it as Administrator.
-
Select one of the following options:
■ Shelf, Step, Position - suitable for farm servers to mark the location of the servers.
■ Default - suitable for home servers. -
Click Start.
The IP address will be displayed in a window on your computer screen.
- In your web browser, enter the IP address provided.
- Proceed to login using root for both the username and password.
- In the Protocol section, you can assign a Static IP address (optional).
- Enter the IP address, Subnet mask, gateway and DNS Server.
- Click “Save”.
- Click https://support.bitmain.com/hc/en-us/articles/360018950053 to learn more about gateway and DNS Server.
3. Configuring the Server
Setting up the Pool
To configure the server:
- Click Settings marked below.
Note:
Fan speed percentage can be adjusted, but we recommend to keep the default
setting. The server will adjust the fan speed automatically if the fan speed
percentage has yet been selected.
- Set the options according to the following table:
- Click Save after the configuration.
4. Monitoring Your server
To check the operating status of your server:
- Click dashboard marked below to check the server status (taking L7 9500T as an example).
Note: The L7 server (9500T) is with fixed frequency 1850 MHz. Firmware will
stop running when the Temp (Outlet) reaches to 80there will be an error
message “over max temp, pub temp (real-time temp)” shown on the bottom of
kernel log page. Meanwhile, the server temperature on the dashboard interface
turns to abnormal and shows “Temp is too high”.
- Monitor your server according to the descriptions in the following table:
5. Administering Your Server
5.1 Checking Your Firmware Version
To check your firmware version:
- Enter the backstage of your server, find the firmware version on the bottom.
- Firmware Version displays the date of the firmware your server uses. In the examples below, the server is using firmware
version 20210701.
5.2 Upgrading Your System
Make sure that the L7 server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
To upgrade the server’s firmware:
- In System, click Firmware Upgrade.
-
For Keep Settings:
■ Select “keep settings” to keep your current settings (default). ■ Unselect “keep settings” to reset the server to default settings. -
When the upgrade is completed, restart the server and it will turn to the setting page.
5.3 Modifying Your Password
To change your login password:
- In System, click the Password tab.
- Set your new password, then click Save.
5.4 Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds.
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Environmental Requirements
Please run your server in accordance with the following requirements
- 1. Basic Environmental Requirements:
- 1.1. Climatic Conditions:
-
1.2. Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources: For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km. For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km. For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km. If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source. Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, equipped with air conditioning for cooling. -
1.3. Electromagnetic Environmental Conditions: Please keep your site away from transformers, high-voltage cables, transmission lines and high-current equipment, for example, there should be no high-power AC transformers (>10KA) within 20 meters, and no high-voltage power lines within 50 meters. Please keep your site away from high-power radio transmitters, for example, there should be no high-power radio transmitters (>1500W) within 100 meters.
-
2. Other Environmental Requirements The server running room shall be free of explosive, conductive, magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:
-
2.1 Requirements of Mechanical Active Substances
2.2 Requirements of Corrosive Gas
Regulations:
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>