HAVIT Lightning HV2860W Tekk LED Deck lights Instruction Manual

June 4, 2024
HAVIT LIGHTNING

**HAVIT Lightning HV2860W Tekk LED Deck lights Instruction Manual

**

Product Specification

Model No. HV2860W HV2860N HV2860C
Name Tekk
Material 316 Stainless Steel Cover + Aluminium Body
Colour Stainless Steel
IP Rating IP67
Input Voltage 12v DC
Lamp Base Built in LED
Protection Class  (Low Voltage)
Lamp Wattage 1x 3w
Colour Temp 3000k 4000k 5500k
Lumens 160lm 170lm 180lm
CRI > 80
Wiring Parallel
Dimmable No
Warranty 3 Years Replacement*

Dimension

Important Safety Issues

  • This product must be installed by a qualified electrician according to AS/NZS 3000.
  • Ensure all electrical mains are disconnected before any installation.
  • Modification of this product will void any warranty.
  • Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
  • When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required and cannot be installed more than 25m from LED Driver, if not within this allowance warranty will be voided.
  • Aluminium and 304SS fittings must not be installed within 5km of any salt water environments.
  • This fitting is not suitable for inground installation
  • All o-rings and seals must be in place correctly to maintain warranty.
  • These instructions may be updated at any time due to product improvements, Please visit website for most currentinstallation instructions.

Sample Wiring Diagram

Steps for Installation

  1. Make sure that the electrical circuit is free of voltage (master switch off )
  2. Make a hole where fitting is to be placed using dimensions provided on line drawings,
  3.  Using an appropriate 12v DC LED Driver – DO NOT CONNECT LIGHT FITTING DIRECTLY TO 240V
  4. Connect the cable – If more than one fitting installed, wiring must  be done in parallel.
  5.  Strip back the cable on both fitting and cable run and twist the positive cables together. Then connect neutral cables together
  6. Solder all joins using solder and either a heat gun or butane gas torch.
  7. Cover connections using an adhesive lined heat shrink or gel cap to make connection watertight. Failure to do this will void warranty.
  8. Heat the heat shrink or crimp the gel cap making sure all connections are covered.
  9. Insert fitting into hole.
  10. Apply silicon around edge of fitting to prevent any water from getting inside to electrical connections.
  11. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.

Must be installed by a licensed electrician

Contact Details:

143 Beauchamp Road
Matraville NSW 2036
Australia

Tel: 02 9381 8300
Fax: 02 9666 8881
Email: [email protected]
Web: www.havit.com.au

Warranty Terms & Conditions

Additional Information

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HAVIT LIGHTNING User Manuals

Related Manuals