HAVIT Lightning HV2860W Tekk LED Deck lights Instruction Manual
- June 4, 2024
- HAVIT LIGHTNING
Table of Contents
**HAVIT Lightning HV2860W Tekk LED Deck lights Instruction Manual
**
Product Specification
Model No. | HV2860W | HV2860N | HV2860C |
---|---|---|---|
Name | Tekk | ||
Material | 316 Stainless Steel Cover + Aluminium Body | ||
Colour | Stainless Steel | ||
IP Rating | IP67 | ||
Input Voltage | 12v DC | ||
Lamp Base | Built in LED | ||
Protection Class | (Low Voltage) | ||
Lamp Wattage | 1x 3w | ||
Colour Temp | 3000k | 4000k | 5500k |
Lumens | 160lm | 170lm | 180lm |
CRI | > 80 | ||
Wiring | Parallel | ||
Dimmable | No | ||
Warranty | 3 Years Replacement* |
Dimension
Important Safety Issues
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required and cannot be installed more than 25m from LED Driver, if not within this allowance warranty will be voided.
- Aluminium and 304SS fittings must not be installed within 5km of any salt water environments.
- This fitting is not suitable for inground installation
- All o-rings and seals must be in place correctly to maintain warranty.
- These instructions may be updated at any time due to product improvements, Please visit website for most currentinstallation instructions.
Sample Wiring Diagram
Steps for Installation
- Make sure that the electrical circuit is free of voltage (master switch off )
- Make a hole where fitting is to be placed using dimensions provided on line drawings,
- Using an appropriate 12v DC LED Driver – DO NOT CONNECT LIGHT FITTING DIRECTLY TO 240V
- Connect the cable – If more than one fitting installed, wiring must be done in parallel.
- Strip back the cable on both fitting and cable run and twist the positive cables together. Then connect neutral cables together
- Solder all joins using solder and either a heat gun or butane gas torch.
- Cover connections using an adhesive lined heat shrink or gel cap to make connection watertight. Failure to do this will void warranty.
- Heat the heat shrink or crimp the gel cap making sure all connections are covered.
- Insert fitting into hole.
- Apply silicon around edge of fitting to prevent any water from getting inside to electrical connections.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Must be installed by a licensed electrician
Contact Details:
143 Beauchamp Road
Matraville NSW 2036
Australia
Tel: 02 9381 8300
Fax: 02 9666 8881
Email: sales@havit.com.au
Web: www.havit.com.au
Warranty Terms & Conditions
Additional Information
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>