PROLED Downlight Sol IP-xx – L710SIx0xx Instruction Manual

June 6, 2024
PROLED

![PROLED CL-x - L710SCxxxx Downlight Sol -[ logo](https://manuals.plus/wp- content/uploads/2022/02/PROLED-CL-x-L710SCxxxx-Downlight-Sol-logo-300x76.png) PROLED DOWNLIGHT SOL IP-xx – L710SIx0xx

Characteristics:

  • SMD Chip in Warm White or Neutral White

  • LED power 4.5, 9, 11.5 and 25 Watt (IP-XS, IP-S, IP-M, IP-XL)

  • Metal housing round or square in White

  • Beam angle 120°

  • Driver 500 mA (IP-S & IP-M) or 1050 mA (IP-XL) constant current (driver not included).
    SOL IP-XS inclusive driver.

  • Dimmable with special 500 mA (IP-S & IP-M) or 1050 mA (IP-XL) constant current dimmer or constant current driver. SOL IP-XS not dimmable.

  • Operating temperature range -10° C till +45° C

  • CE compliant with applicable European directives

Warning:

  1. Due to IP54 classification this luminaire is suitable for wet room.
  2. Please ensure that the packaging is disposed of in a safe environment
  3. If cable is defected, do not use the luminaire
  4. We do recommend that a qualified electrician should be used to install the products
  5. Do not look at the lighted luminaire directly

Safety indices:

Be sure to have a qualified electrician complete installation. The customer is not entitled to claim for any lights installed without observing European safety directives. The manufacturer is then discharged from liability when damage is caused by improper use or installation. If any luminaire is subsequently modified, the person responsible for the modification shall be considered as manufacturer. Do not cover lamps with heatinsulating materials. Suitable for wet rooms. Protection class IP54.

Installation:

Please follow the sequence of installation step by step. Non-observance can lead to damage of LED.

  1. Switch off the electricity at the mains before commencing installation or lamp change and (if a fuse box is installed) remove the appropriate circuit fuse to avoid accidental switching on of the mains supply.
  2. Connect to a constant current driver 500 mA (IP-S & IP-M) or 1050 mA (IP-XL) (secondary side)
  3. Connect primary side of driver to power supply (230V)
  4. Make sure all connections are tight with no loose strands
  5. Ensure fire regulations are not breached when fitting your lights 6. If you are in any doubt regarding these instructions, consult a qualified electrician

Please follow the sequence, if not destroying of LED:

First

PROLED Downlight Sol IP-xx - L710SIx0xx - ddiver

Second

PROLED Downlight Sol IP-xx - L710SIx0xx - included

PROLED Downlight Sol IP-xx - L710SIx0xx - icon

Installation steps

  1. Check if existing space is enough to fit the luminaire
    PROLED Downlight Sol IP-xx - L710SIx0xx - steps

  2. Shut off fuse in fuse box. Connect luminaire to driver only after power-off.

  3. Steps during installation
    PROLED Downlight Sol IP-xx - L710SIx0xx - installationIP-XS Round/Square: Ø 55 mm
    IP-S Round/Square: Ø 105 mm
    IP-M Round/Square: Ø 135 mm
    IP-XL Round/Square Ø 195 mmPROLED Downlight Sol IP-xx - L710SIx0xx -
Make

  4. Shut on fuse in fuse box. The luminaire can be used now.

Energy efficiency class of the light source:

Products listed in this manual contain a light source of following efficiency class, listed according to the item codes:

Item code Efficiency class of light source
L710SIK06R F
L710SIK08R F
L710SIK06S F
L710SIK08S F
L710SIS06R E
L710SIS08R E
L710SIS06S E
L710SIS08S E
L710SIM06R E
L710SIM08R E
L710SIM06S E
L710SIM08S E
L710SIX06R E
L710SIX08R E
L710SIX06S E
L710SIX08S E

09.21 Technical amendments reserved
MBN GmbH, Balthasar-Schaller-Str. 3, 86316 Friedberg – Germany
www.proled.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals