BANNER WLS70 Industrial LED Strip Light User Guide

June 6, 2024
BANNER

WLS70 Industrial LED Strip Light (AC)

Quick Start Guide
This guide is designed to help you set up and install the WLS70 Industrial LED Strip Light (AC). For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at www.bannerengineering.com. Search for p/n 220753 to view the Instruction Manual. The use of this document assumes familiarity with pertinent industry standards and practices.

Important: Read the following instructions before operating the light. Please download the complete WLS70 Industrial LED Strip Light (AC) technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device.

Models

*Cascadable models only available with QM connection.
**Models with a quick disconnect require a mating cordset. See Cordsets on p. 3.

Installing the WLS70 Industrial LED Strip Light

Figure 1. Attaching the Clamp Brackets (Step 3)

Figure 2. Verifying the Cascade Cover is Attached (Step 10)

  1. Turn off power at fuse or circuit breaker box.

  2. Remove the light from the packaging and inspect it for damage before installing it.

  3. Attach the included LMBWLS70T clamp brackets to the light. Slide on gasket if desired.
    Refer to the instruction manual for a complete list of compatible brackets.

  4. Select a suitable horizontal or vertical mounting location.

  5. Place the light in the mounting location and mark the positions of the bracket mounting holes.
    The optional LMBWLS70HK bracket can be used to hang the light in conjunction with the LMBWLS70T (see Brackets on p. 3).

  6. Drill the holes and use appropriate screws to secure the bracket to the mounting location.

  7. Clamp the light onto the brackets.

  8. When daisy-chaining multiple lights, follow steps 1 through 5 to mount additional lights. See the application note in Specifications on p. 2 for the maximum allowed lights daisy-chained together and maximum allowed cable run when choosing mounting locations.

  9. Connect the daisy-chained units together using cascade cord sets (see Cordsets on p. 3).

  10. Verify the supplied cascade cover is on the output connector of the last light in the chain.

  11. Attach cables (cabled model) or corsets (quick-disconnect model) per the wiring diagram. Terminate wire as appropriate per application.

Installation is complete. Turn on electricity at fuse or circuit breaker box.

WARNING:

  • Risk of electric shock
  • Failure to follow these instructions could result in serious injury or death.
  • Disconnect or turn off the power before installing, removing, or servicing the device.
  • Install and connect the device in accordance with the National Electrical Code (NEC) and any applicable local code requirements and supply the device with an appropriate fuse box or circuit breaker (see Specifications).

Wiring Diagram

Specifications

Supply Voltage
Nominal voltage: 120 V AC to 277 VAC, 60 Hz in North America
Nominal voltage: 100 V AC to 277 V AC, 50/60 Hz outside North America
Power factor: > 0.95 at 120 V AC and > 0.90 at 277 V AC
Total harmonic distortion (THD): < 20%
See electrical characteristics on the product label

Application Notes
When connecting continuous run/cascadable lights in series, it is important not to exceed the maximum current limitations of 8A. For example, the typical current draw of a 1200 mm fixture at 120 V is 0.315A. 8A/0.315A yields a maximum of 25 fixtures cascaded together.
Two or more lights installed in parallel must maintain a 150 mm (6 inches) spacing to maintain a 50 °C operating temperature.
Certifications and Approvals

UL/cULus E338626

Dimming
Compatible with 0–10 V analog LED dimming, dimmable to 5% intensity
Dimming current: <1.0 mA
Supply Protection Circuitry
Protected against transient voltages
Construction
Clear anodized aluminum housing; polycarbonate outer housing
Mounting
Several optional mounting brackets are available (see Accessories)
Connections
Integral 5-pin 7/8/Mini-style quick disconnect (8A / 300V / 2.5kV / 2), (5-pin connecting cordset required); or 2 m (6.5 ft) integral STOOW UL/HAR PVC cable
See Cordsets on p. 3
Environmental Rating
IEC IP65
LED Lifetime
When operating within specifications, the output will decrease less than 30% after 50,000 hours.

Operating Temperature
Surface Mount Installation: –40 °C to +50 °C (–40 °F to +122 °F) 85% at +50 °C maximum relative humidity (non-condensing)
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6 (5-minute sweep, 30-minute dwell)
Shock: 15G 11 ms duration, half-sine wave per IEC 60068-2-27 Impact: IK10 (IEC 60068-2-75)

Light Characteristics
Daylight White Efficacy: up to 143 lumens/watt typical at 120 V AC at 25 °C (77 °F)
CRI: 82, typical

Model| Color Temperature (CCT)| Lumens (Typical at 25 °C)| Watts at 120 VAC| Luminous Efficacy (Im/w)
---|---|---|---|---
300| Daylight White| 5000 K (±300 K)| 1350| 10.| 141
600| Daylight White| 5000 K (±300 K)| 2700| 20.| 136
900| Daylight White| 5000 K (±300 K)| 4050| 29.| 141
1200| Daylight White| 5000 K (±300 K)| 5400| 38.| 143

Dimensions

All measurements are listed in millimeters [inches], unless noted otherwise.

Model Housing Length (L1) Lighted Length (L2)
WLS70..300.. 369.8 302
WLS70..600.. 667.6 600
WLS70..900.. 965.3 898
WLS70..1200.. 1263 1196

Accessories

Brackets
All measurements are listed in millimeters unless noted otherwise. Refer to the instruction manual for a complete list of compatible brackets.

LMBWLS70T

  • Stainless steel
  • Includes two clamp brackets for hanging or surface mount, two anti-rotation gaskets, and stainless steel hardware for securing the bracket to the light
  • For use with M8 or 5/16″ mounting hardware

Note: The LMBWLS70T is supplied with the light.

LMBWLS70HK

  • The hanging bracket kit allows for suspended installation
  • Includes two hanging bracket assemblies
  • For use with bracket LMBWLS70T

Cordsets

5-Pin Threaded 7/8-in Cordsets–Single Ended

Model| Length| Style| Dimensions| The pinout (Female)
MBCCL-506| 2 m (6.56 ft)| Straight| |
MBCCL-515| 5 m (16.4 ft)
MBCCL-530| 9 m (29.5 ft)
5-Pin Threaded 7/8-in Cordsets–Double Ended

Model| Length| Style| Style| Style
MBCCL-503SS| 1 m (3.28 ft)| Female Straight/Male Straight| |
MBCCL-506SS| 2 m (6.56 ft)
MBCCL-512SS| 4 m (13.1 ft)
MBCCL-520SS| 6 m (19.7 ft)

Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for the misuse, abuse, or improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING, OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.

FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)

This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the manufacturer.

Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269
81 8363.2714
© Banner Engineering Corp. All rights reserved
WLS70 Industrial LED Strip Light (AC)
P/N 216262 Rev. D
www.bannerengineering.com – Tel: + 1 888 373 6767

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals