KS VERLICHTING 7737 Outdoor Charge Timer Garden Socket Instruction Manual
- October 27, 2023
- KS VERLICHTING
Table of Contents
KS VERLICHTING 7737 Outdoor Charge Timer Garden Socket
Assembly and installation instructions
- The light fitting/sockets must be installed by a qualified electrician. The main supply must be disconnected at the fuse box before starting installation. Before starting with installation, use a voltage tester to make sure the wiring is off circuit. It is not sufficient just to turn off the power at the switch. You also need to ensure that in relation to the earthing on the electrical lead the local regulations are observed. Make sure you have a solid foundation.
- Place the pole on the ground. Boreholes silhouetted on the foundation. Drill the necessary holes. Insert the plugs.
- Pull the strip with the terminal block from the socket. Attach the wires and keep the correct colors in track: Blue lead = Neutral (N). Brown or Black lead = Live (L). Yellow/Green lead = Earth (not on class II light fittings). Note that: the (brown) wire L1 corresponds to the mains cable L (or the connector marked with the symbol L), the (blue) wire N1 corresponds to the neutral conductor N (or the connector marked with the symbol N), the (yellow / green) wire 1 corresponds to the earth cable (or the luster terminal with symbol ). Place the strip back into the socket. The socket is now ready for installation on the foundation.
- The socket t is now ready for use. Switch on the main supply.
Maintenance requirements: It is recommended that the surface is rubbed regularly with a neutral oil or water without cleaning agents and then wiped with a soft cloth. Keep the armature free from a salty environment, coastal location and an acid free environment, this affects the armature. Rub it regularly with Carwash, it ensures a longer lifetime of the armature.
Instruction manual for timer
Setup procedures: Push indicator outside, each indicator 15min, power on when
indicator is pushed to outside. e.g.: setup timer working on 8:00am-11:00am
and 13:00pm-17:00pm, only need to push all the indicators which belong to
these two periods outside.
Set current time: Turn the dial clockwise, make the triangle arrow point
to the current moment. e.g.: current time 8:00am, turn the dial clockwise,
make the triangle arrow points to the number 8. Push green time switch to
location, then the controlled electrical appliances will be set and had
Timer function. Push green time switch to location, then no timer
function for controlled electrical appliances.
Note:
If the indicator which is pointed by the triangle arrow can not be pushed
outside, just turn the dial clockwise and make this indicator is not pointed.
If there is power off, must recalibrate current moment. Unless change the
setting, otherwise keep the same setup procedures everyday.
Caution, risk of electric shock! Do not disassemble the mechanical timer.
When repairing, please always consult a qualified electrician in accordance
with local safety regulations for help and use original.
- Connect the power and set the hour indicator according to the actual time.
- Set timer, press indicator outside (each indicator – 15 min).
- Activate timer
- Deactivate timer
OPERTAION
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>