tpi 608BT Digital Manometer Instruction Manual
- June 6, 2024
- TPI
Table of Contents
608BT Digital Manometer
Instruction Manual
The Value Leader
Visit www.tpieurope.com
INTRODUCTION
1. Congratulations: Thank you for purchasing TPI products. The 608(BT) is
easy to use and built to last. Please remember to complete product warranty
registration on our website at www.tpieurope.com.
2. Product Description: The 608(BT) digital manometer measures pressure or
vacuum in four units of measure. Please follow manufacturer recommendations on
all equipment being serviced with the 608(BT).
SAFETY CONSIDERATIONS
- Wear safety goggles.
- Make sure system pressure does not exceed the capability of the 608(BT) before connection.
- Check all connections making sure they are secure with no leaks.
- Observe all manufacturer’s recommendations.
General Specifications
Sensor Type | Temperature-compensated solid state |
---|---|
Connector Type | Standard 1/4” Barb Fitting |
Range | -150 mBar to + 150 mBar |
Units of Measure | PSI, bar, KPa, inH2O |
Over Pressure | +/- 300 mBar |
Operating Temperature | -10° to 50°C (14° to 122°F) |
Power Supply | 9 Volt Alkaline |
Accuracy
Measurement | Range | Resolution | Accuracy |
---|---|---|---|
inH2O | +/-(0.01 to 29.99) | 0.01 | +1- 0.3 inH2O |
+/-(30.0 to 60.0) | 0.1 | +1- 0.6 inH2O | |
mbar | +/-(0.01 to 29.99) | 0.01 | +1- 0.3 mbar |
+/-(30.0 to 150.0) | 0.1 | +1- 1.5 mbar | |
KPa | +/-(0.001 to 2.999) | 0.001 | +1- 0.03 KPa |
+/-(3.00 to 15.00) | 0.01 | +1- 0.15 KPa | |
PSI | +/-(0.001 to 2.175) | 0.001 | +1- 0.021 PSI |
MEASUREMENT TECHNIQUES
- Turn the 608(BT) on by pressing the ON/OFF key. The display will initially read “608” along with “APO” or “- – – -”, and the selected unit of measure. After this initial display, the 608(BT) is ready for use.
Please see pages 4 to 6 to connect Bluetooth version to the FREE TPI View app. for enhanced features.
APO = Auto Power Off enabled – the 608 will turn off after 20 minutes
– – – – = Auto Power Off disabled – the 608 will stay on until turned offFollow these steps to change the unit of measure and to enable or disable auto power off as required.
a) With the 608 turned off, press and hold the ON/OFF key until the display flashes “APO” or “—-” and the unit of measure annunciator.
b) Release the ON/OFF key and then press it repeatedly until the desired unit of measure is displayed. The unit of measure annunciators will cycle through mmH2O, mbar, KPa, PSI, and inH2O each time the ON/OFF key is pressed.
c) Press the ZERO key to enable or disable auto power off. “APO” displayed indicates auto power-off is enabled, “- – – -” displayed indicates auto power- off is disabled. Pressing the ZERO key cycles between these two options.
d) Once the desired unit of measure and auto power-off mode is selected, allow the 608 to turn off and then turn it back on and proceed with testing. The 608 will turn on in the last selected unit of measure and auto power-off mode until changed.
- Zero the displayed reading by pressing the ZERO button.
- Connect the 608(BT) to the device under test.
Additional Features
Backlight – The backlight can be activated to make the display easier to see in dark environments. Press the BL button to turn the backlight on. The display will light up and “BL” will be displayed. To preserve battery life, the backlight will remain on for 15 seconds and then turn off.
Case Magnets – The 608 back case is equipped with magnets and a hook.
and Hook This allows the 608 to be secured during tests.
ACCESSORIES
Item # Description
A009A …………9 Volt Alkaline Battery (included)
A616 …………..Soft Carrying Pouch (optional)
A608BT ……….Splashproof Protective Cover (optional)
MAINTENANCE
- Clean the surface of the instrument using a damp cloth.
- Replace the 9 Volt battery when the low battery indicator appears on the LCD.
TROUBLESHOOTING
Symptom | Probable Cause |
---|---|
Display reads “oFL” | Pressure over range Low battery. |
Damaged sensor.
608 does not turn on.| Dead or low battery.
Defective POWER ON switch.
Broken battery connector.
WARRANTY
This product is warranted to the purchaser against defects in material and workmanship for three years from the date of purchase.
Covered by Warranty: Repair parts and labor; or replacement of the product at the company’s option. Normal transportation charges to the purchaser are also covered.
Not Covered by Warranty: Damages to the product which are the result of
abuse, improper use, or maintenance are not covered. Any other expense,
consequential damages, incidental damages, or incidental expenses including
damages to property are not covered.
Transportation expenses to the company are not covered.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
To Obtain Warranty Performance: Include with the product: your name, address, phone number, written description of the problem and proof of purchase date. Carefully package and return to:
TPI, Inc.
9615 SW Allen Blvd.
Beaverton, OR 97005
USA| TPI, Ltd.
342 Bronte Rd. S., Unit 9 Milton, Ontario L9T 5B7
Canada| TPI, Europe Ltd.
Unit 6 Rutherford Way Ind. Est.
Crawley, W.Sussex. RH10 9LNEngland
---|---|---
Implied Warranties: Any implied warranties including implied warranties
of merchantability and fitness for a particular
purpose, are limited in duration to three years from the date of purchase. To
the extent any provision of this warranty is prohibited by federal or state
law and cannot be preempted, it shall not be applicable.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
608BT BLUETOOTH VERSION
-
Congratulations: Thank you for purchasing TPI products. The 608BT is easy to use and built to last. It is backed by a 3-year limited warranty.
-
Product Description: The 608BT is a Single Input Manometer Pressure “Smart Probe”. It connects to your mobile device and uses the TPI View App to display pressure readings & perform Let/By Tightness Test.
Data can be displayed, saved, logged, allocated to a specific job & e-mailed from within the TPI View app once the 608BT is connected to it. -
Download the View app from either the Apple App Store or the Google Play Store.
TPI View Apphttp://onelink.to/kt8sss
As simple as 1, 2, 3
Perform various types of pressure tests such as Live Pressure, Fan Pressure, Working Pressure & even FULL UK Let ByTightness Tests using the FREE TPI View app.
Create JOBS before you start taking readings| Give each report a different
reference/name| Save to a JOB, Print or E-mail, or ALL 3 – the Choice is
Yours!!| Save to an existing JOB or create a NEW one
---|---|---|---
| | |
The 608BT has been tested with the following standards and is in compliance with the council RED directive 2014/53/EU: –
Thank You!!!!!
& Welcome to the TPI Family
We really appreciate you coming on board, if you aren’t already, and look
forward to serving you over the next few years, and beyond. For the best
experience head over to www.tpieurope.com, create
your account, and register your product.
Benefits include:
- Everything in one place
- Create service, calibration, and warranty/repair requests
- Download certificates
- Contact sales, support, and customer service
- Read correspondence from TPI including Service updates
- Manage your order history
- Shop Online for accompanying products and spares
- delivered directly to your door
Please do not hesitate to contact us by any of the following methods:Tel:
01293 530196
E-mail: sales@tpieurope.com or
service@tpieurope.com
Website: www.tpieurope.com inc. LIVECHAT
Facebook: @tpieurope
Twitter: @TPIEuropeLTD
Test Products International Europe Ltd.
Unit 6 Rutherford Way Industrial Estate
Crawley, West Sussex RH10 9LN
Tel:: +44 (0) 1293 530196
www.tpieurope.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>