tpi SP620 Differential Manometer Smart Probe Instruction Manual
- October 30, 2023
- TPI
Table of Contents
SP620 Differential Manometer Smart Probe
Test Products International, Inc.
Connects to smart phone and uses the TPI Smart Probe App or the TPI View App
Perform differential pressure measurements
Up to 6 SP620 smart probes can connect to a single mobile device (most devices)
Timed UK Let/By – Tightness Test function (View App ONLY)
UK Working Pressure Test (View App ONLY)
3 Year Limited Warranty
Test the TPI Advantage
Visitwww.tpieurope.com
A. INTRODUCTION
-
Congratulations: Thank you for purchasing TPI products. The SP620 is easy to use and built to last. It is backed by a 3 year limited warranty.
-
Product Description: The SP620 is a Differential Manometer Pressure “Smart Probe”. It connects to your mobile device and uses the TPI Smart Probe App or TPI View App to display differential pressure readings.
Data can be displayed, saved, logged, allocated to a specific job, exported & e-mailed in either pdf or csv depending on which app the SP620 is connected to. -
Download either the SmartProbe or the View app from either the Apple App Store or the Google Play Store
SmartProbes App
View App
B. SAFETY CONSIDERATIONS
- Never attach the SP620 to a hot surface.
- Always ensure the pressure being measured does not exceed the capability of the SP620.
- Never use the SP620 to measure liquid pressure.
- Do not expose the unit to damp environments for extended periods of time.
C. SPECIFICATIONS
SP620 Smart Probe Differential Pressure Meter Specifications
Input Type| Dual Input differential
Connection Type| 1/4 inch barb
Measurement Range| -150 mbar to 150 mbar (-60 in H2O to 60 in H2O)
Accuracy| +1-0.05 mbar (0 to 1 mbar) / +/-(1.5% + 20 digits) (> 1 mbar)
+/-0.02 inH2O (0 to 1 inH2O) / +/-(1.5% + 20 digits) (> 1 inH2O)
Resolution| 0.01 mbar / 0.01 inH2O
Units of Measure| 7 Units (mbar, inH2O, kPa, PSI, mmHg, InHg, mmH2O)
Operating Temperature| -20°C to 50°C (-4°F to 122°F)
Communication| Bluetooth version 4.2 (Use with TP1 Smart Probe App)
FCC ID: Q0Q8GM113
IC: 5123A-BGM113
209-J00204
Battery Type| AAA x 3
Battery Life| 80 hours typical
D. INSTRUMENT OVERVIEW
- Input connection for pressure measurements. Inputs are marked + and -.
- SP620 status LED indicator. Orange and blinking = Bluetooth not connected Green and blinking = Bluetooth connected Blinking Red with either of the above = Low battery
- Power Key. Press and hold to turn the instrument on. Press and hold to turn the instrument off.
- Built-in magnet. Attach to metal surfaces for hands free operation. Ensure surface is not hot.
- Serial number location. Last three digits are the product identification number and marked in bold. Use this number to distinguish between models when several SP620’s are connected to a phone or tablet.
- Screw to open battery compartment. Turn the screw counter clockwise until it is just above the compartment door. Lift on the screw to open the compartment.
A: The inputs are marked + and -. Any pressure connected to the – port will be subtracted from the + port.
For standard pressure / vacuum measurements use the + port only.
Use the + and – port when performing differential measurements.
E. MAINTENANCE
- Clean the surface of the instrument with a damp cloth.
- Replace the three AAA batteries when the low battery indicator appears.
F. TROUBLE SHOOTING
Symptom | Probable Cause |
---|---|
Pressure seems inaccurate. | • Check tubing for kinks or cuts. |
• Low battery.
• Ensure connection with smart device is working.
SP620 does not turn on.| • Dead or low batteries.
• Not holding down power switch until unit turns on.
• Defective POWER ON switch.
SP620 displays “OL”.| • Pressure limit exceeded.
G. ACCESSORIES
Included Accessories
Part Number | Description |
---|---|
A620SP | Soft pouch |
Optional Accessories
Part Number | Description |
---|---|
A925 | Carrying case for 4 smart probes |
A930 | Carrying case for 1 or 2 smart probes |
H. WARRANTY
This product is warranted to the purchaser against defects in material and workmanship for three years from the date of purchase.
Covered by Warranty: Repair parts and labor; or replacement of the
product at company’s option. Normal transportation charges to the purchaser
are also covered.
Not Covered by Warranty: Damages to the product which are the result of
abuse, improper use or maintenance are not covered. Any other expense,
consequential damages, incidental damages, or incidental expenses including
damages to property are not covered. Transportation expenses to the company
are not covered.
To Obtain Warranty Performance: Include with the product: your name, address, phone number, written description of the problem and proof of purchase date. Carefully package and return to:
TPI, Inc.
9615 SW Allen Blvd.
Beaverton, Or 97005
USA
503-520-9197
www.testproductsintl.com
TPI Canada
342 Bronte rd. S., Unit 6
Milton, Ontario L9T 5B7
Canada
905-693-8558
www.tpicanada.com
TPI, Europe Ltd..
Longley house, International Drive
Southgate Crawley
West Sussex RH10 6AQ England
44(0) 1293 530196
www.tpieurope.com
Implied Warranties: Any implied warranties including implied warranties of merchantability and fitness for a particular purpose, are limited in duration to three years from date of purchase. To the extent any provision of this warranty is prohibited by federal or state law and cannot be preempted, it shall not be applicable. This warranty gives you specific legal rights, and you may also have other rights which vary from country to country.
I. REPLACING BATTERIES
- Turn the battery compartment screw counter clockwise until it is just above the compartment door. Lift on the screw to open the compartment.
- Replace the three AAA batteries.
- Re-install the battery cover and tighten the screw by turning it clockwise.
Test Products International, Inc.
9615 SW Allen Blvd., Ste. 104
Beaverton, OR 97005
Tel: 503-520-9197
www.testproductsintl.com
Test Products International, Ltd.
342 Bronte Road South, Unit#6
Milton Ontario Canada L9T 5B7
Tel: 905-693-8558
www.tpicanada.com
Test Products International Europe Ltd.
Longley House, International Drive
Southgate, Crawley, West Sussex RH10 6AQ
Tel:: +44 (0) 1293 530196
www.tpieurope.com