InCarTec RunSwitch 7.5 Amp Power Modules Installation Guide
- June 6, 2024
- InCarTec
Table of Contents
- INSTALLATION GUIDE
- WIRE CONNECTIONS - ALL PRODUCTS
- TIMER MODE - RUNSWITCH PLUS ONLY
- PROGRAMMING TIMER
- BATTERY SAVER MODE - RUNSWITCH PLUS ONLY
- CHANGING MODES BATTERY SAVER/TIMER MODE
- BATTERY SAVER MODE SETTING:
- TIMER DISABLE MODE
- PROGRAMMING TIME DELAY DISABLE MODE
- NOTES
- TECHICAL SPECIFICATIONS – ALL PRODUCTS
- References
INSTALLATION GUIDE
WIRE CONNECTIONS - ALL PRODUCTS
A FUSE 7.5 Amp
B YELLOW 12V Constant Input
C BLACK Chassis Ground
D RED 12V Accessory Output
RunSwitch products immediately detect when the engine is on or off - providing switched 12V output to accessories with the engine on and turning accessories off when the engine is off.
Internal LED fuses allow for quick and easy set-up, functional circuit confirmation and diagnostics.
YELLOW: Connect directly to 12V battery (+) terminal or any 12-volt constant circuit. This is the INPUT power to RunSwitch and requires a constant power connection directly from the 12V battery.
BLACK: Connect to system Ground. This could be the vehicle chassis or direct connection to the (-) terminal on the 12V battery.
RED: Connect this wire to the accessory (+) INPUT that is typically connected to 12V power. The accessory GROUND wire will require a connection to chassis or (-) to complete the circuit.
When more than 7.5 amps are needed RunSwitch products can trigger multiple 30-amp relays.
TIMER MODE - RUNSWITCH PLUS ONLY
The timer function is the default mode (3-min) from the factory. The timer enables the accessory output to remain ON for a predetermined amount of time after the engine is turned OFF. The Timer Delay function is user-adjustable from 1 to 90 minutes. In Timer mode, the LED will blink when engine is OFF, indicating that the timer function is enabled, and timer countdown is progressing. Once timer delay has elapsed, the LED & accessory output will turn OFF. Timer function will be repeated on next Engine ON/OFF cycle.
Typical Uses:
Accessory power for components that can be disabled after a delay once engine
has been turned off.
The timer mode has a 2-Tier level for programming the delays
1X – 1~9 minutes (factory default 3-minute delay)
10X – 10~90 minutes
PROGRAMMING TIMER
STATUS:
Engine running, Module powered = ON, LED=ON, fuse illuminated.
TIME DELAY SETTING:
- With the engine running, hold push button for >10 seconds. Release push button when LED starts to blink. LED will blink in a 9-flash sequence. Each LED flash represents a 1-minute interval of delay for selection.
- Select delay value by pressing push button AFTER the desired blinks (1 blink represents 1 minute of delay).
- Release push button when LED begins to flash the confirmation sequence (repeats the selection of blinks).
- The number of LED blinks will represent the delay value entered for confirmation.
EXAMPLE: If push button is pressed after 6 flashes of the LED, this equates to a 6-minute delay time. LED will then flash 6X to confirm the delay value entered was 6 minutes.
ACCEPT SELECTION:
1X (1To accept the value, press and hold the push button until the LED flashes
2 times, then release push button. This exits the delay programming mode and
new delay value is stored. Timer mode is restored for operation.
10X (10-90 Minutes)
To accept the value, press and hold the push button beyond when the LED
flashes 2 times , continue holding the push button until the LED blinks
continuously at a fast rate. Then release. This exits the delay programming
mode, and new 10X delay value is stored. Timer mode is restored for operation.
ABORTING TIME DELAY VALUE:
During programming, if the push button is not pressed again during any steps in the programming sequence (or loss of power during programming) the program will abort & resume using the previous stored delay value in memory (factory default 3-minutes) No new data will be stored unless the user confirms by entering / storing the values using the push button.
The 9-blink LED sequence will repeat 5X. If no selection is made during the 9-blink sequence, the program will abort and revert back to the previous stored delay value from memory . This allows the user to ignore a changed value or enter a new value.
- NOTE: If you do not continue with programming at any time during the sequence, the module will default back to the previous delay setting from memory after a few minutes or if power is removed during the procedure.
BATTERY SAVER MODE - RUNSWITCH PLUS ONLY
Battery Saver Mode is a function that enables the accessory output to remain ON after engine is turned OFF. The timer function is removed, and module will automatically monitor the battery charge level, automatically turning output OFF if battery level falls below a predetermined safe voltage level (approximately ~11.5VDC).
This function is used for extended operation of accessory components without the fear of having a dead battery when required to re-start engine.
** NOTE: Battery Saver mode is also operational during TIMER mode as a convenience feature
CHANGING MODES BATTERY SAVER/TIMER MODE
STATUS:
Engine OFF, Module powered = OFF, LED=OFF, fuse not illuminated.
BATTERY SAVER MODE SETTING:
- With engine OFF, press and hold down push button
- While holding push button, start vehicle engine. Continue to hold push button until 2 LED blinks are observed, then release push button to enter Battery Saver mode.
LED will remain ON once Battery-Saver mode is activated. LED will blink twice every 10 seconds, to indicate device is operating in BATTERY-SAVER MODE.
TIMER MODE SETTING: Repeat above steps to revert back to Timer mode
NOTE: Holding push-button during power-up will toggle between Battery- Saver Mode or TIMER Mode. LED status will indicate the mode currently operating.
TIMER DISABLE MODE
The TIMER function delay can be disabled to eliminate the delay. The accessory output will respond directly to engine run / stop when delay is disabled.
PROGRAMMING TIME DELAY DISABLE MODE
STATUS:
Engine OFF, Module powered = OFF, LED=OFF, fuse not illuminated.
TIMER DELAY DISABLE:
- Press & hold push button while you start the engine.
- Continue to hold for 20 LED blinks (~20 seconds).
- Release push button when LED stops blinking and remains ON.
- Timer delay function is now disabled.
Time delay can be re-programmed by entering a 1-minute to 90-minute delay value by following the PROGRAMMING TIMER MODE procedure.
NOTES
- If you do not continue with programming at any time during the sequence, the module will default back to the previous delay setting from memory after a few minutes or if power is removed during the procedure.
** NOTE: Battery Saver mode is also functional in the background during TIMER mode as a convenience feature
*** Any mode selection is retained during power loss or until changed by user.
TECHICAL SPECIFICATIONS – ALL PRODUCTS
WIRE SIZE | 20 AWG Stranded 105C |
---|---|
INPUT VOLTAGE | 12 ~ 16 VDC (Standard Automotive Battery) |
INPUT CURRENT FUSE | 7.5 MAX Amperage |
REVERSE BIAS PROTECTION | Fuse will OPEN if Vin & GND are reversed to protect |
module.
OUTPUT VOLTAGE| 13.6V typical (standard automotive battery power with engine
running)
OUTPUT CURRENT| 100W / 7.5A max current output with engine running (fuse
protected)
SLEEP CURRENT| 0-volt output, 180uA quiescent current (Vin < 12.8V / Key =
OFF, Engine OFF)
ENGINE RUNNING| On when battery voltage increases / alternator charging
ENGINE OFF| OFF when battery voltage decreases / alternator not charging
SLEEP| Engine OFF / Module = OFF; no power output
RATINGS| IP54
OPERATING| -40°C ~ +85°C (USCAR Interior / Below IP)
STORAGE| -40°C ~ +125°C
Optional Single Relay Install
Optional Multiple Relay Install
References
Read User Manual Online (PDF format)