XPOWER P-200T Professional Air Mover 115V-60Hz Owner’s Manual

June 6, 2024
XPOWER

XPOWER P-200T Professional Air Mover 115V-60Hz

XPOWER P-200T Professional Air Mover 115V-60Hz

Introduction

XPOWER Mini Air Movers are certified professional level multifunctional utility blower fans with the most efficient engineering design.

Features

  • Low power draw with high velocity air flow from 600 to 800 CFM
  • Super quiet motor and super lightweight
  • Easy carrying handle and stackable up to 4 units high.
  • Easy and quick to disassemble for thorough cleaning and service.
  • Safety certified 10′ power cord.
  • Easy cord wrap on handle.
  • 3-hour timer.
  • 3-speed switch.
  • Durable and rugged housing.
  • 4 air flow positions (0°, 20° Kickstand, 45° and 90°).

Feature

Operation

XPOWER Mini Air Movers are intended to move air and to dry small areas where the large air mover is not applicable such as crawl spaces, inside cabinets, under counters, inside ceilings, basements, etc. The Mini Air Mover can also be used as a high velocity fan for household indoor/outdoor use.

  1. XPOWER air movers are shipped ready-to-use. Prior to plugging the unit into the power source, inspect completely for any shipping damage.
  2. Plug the electrical cord into the power outlet.
  3. Carefully place the Air Mover on a stable, flat, dry surface.
  4. The unit is capable to be used at 4 different angles to direct airflow.
  5. Turn the switch to select desired speed, while making sure the unit operates normally.
  6. To reduce the risk of injury, close supervision is necessary when the appliance is used near children. Do not allow children to play with or around an air mover at any time.

Operation 2

Safety Instructions

  1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit with wet hands or while standing in water.
  2. To avoid risk of injury, do not direct air flow at face or body.
  3. To reduce the risk of fire or electric shock, do not use the Mini Air Mover with any solid-state speed control device.
  4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and / or installation of a GFCI receptacle if necessary.
  5. Do not operate the Mini Air Mover with a damaged cord or plug. Discard the unit or return it to an authorized service facility for examination and/or repair.
  6. Unplug the Mini Air Mover from the power supply before servicing or cleaning. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or similar coverings. Place the power cord away from traffic area to prevent tripping.
  7. Do not allow children to play with or around the Mini Air Mover at any time.
  8. Do not move or carry the Mini Air Mover while the unit is operating.
  9. To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
  10. An electronic instruction manual can be obtained through manufacture’s website www.xpower.ws

Maintenance Instructions

  1. To keep the Mini Air Mover clean, use a damp cloth to wipe the surface of the housing.
  2. Never clean the unit with water directly.
  3. When not in use, unplug and store the air mover in a dry indoor place out of reach of children.
  4. Always disconnect the air mover from its power source before performing any maintenance or cleaning.

Troubleshooting

For any problems not listed below, call your local distributor or contact our Service Department at 1-855-855-8868

PROBLEM POSSIBLE CAUSE SOLUTION

Air Mover not
running

| No power input| Plug in the Air Mover; check circuit breaker
Switch not turned on| Turn on switch
Air Mover fan wheel jammed| Remove material jamming fan wheel
Intake or exhaust blocked| Turn unit off and allow to cool,
then remove blockage
Air Mover vibrates| Accumulation of dirt on fan blades| Clean Air Mover fan blades

Specifications

Model                         P-200T                          P 200AT P-230AT

Volt / Frequency| 115V / 60Hz| 115V / 60Hz| 115V / 60Hz
Power| 1/8 HP| 1/8 HP| 1/5 HP
Amp| 1.5 Amps| 1.5 Amps| 2.3 Amps
Rated Airflow (On High)| 600 CFM| 600 CFM| 800 CFM
RPM (Low / Medium / High)| 1100 / 1250 / 1500| 1100 / 1250 / 1500| 1000 / 1250 / 1500
Speeds| Three| Three| Three
Built-In Power Outlet / Daisy Chain| No| Yes| Yes
3-Hour Timer| Yes| Yes| Yes
Positions| 4 (0°, 20° Kickstand, 45°, 90°)| 4 (0°, 20° Kickstand, 45°, 90°)| 4 (0°, 20° Kickstand, 45°, 90°)
Unit / Box Weight| 8.5 Lbs. / 9.7 Lbs.| 8.7 Lbs. / 9.9 Lbs.| 9.9 Lbs. / 11.2Lbs.
Unit / Box Size (L x W x H)| 10.7”x12.4”x13.3” / 13.4”x12.6”x11”| 10.7”x12.4”x13.3” / 13.4”x12.6”x11”| 10.7”x12.4”x13.3” / 13.4”x12.6”x11”
Power Cord (Length/Size)| 10’/18AWG| 10’/14AWG| 10’/14AWG
Overheating Protection| Thermally Protected| Thermally Protected| Thermally Protected
Housing| Polypropylene (PP)| Polypropylene (PP)| Polypropylene (PP)
Safety Certificates| ETL / C-ETL| ETL / C-ETL| ETL / C-ETL

XPOWER Limited Warranty (USA)

XPOWER’s Limited Warranty covers the unit (excluding POWER CORD) from defects in material and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.

Important!
This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse, disassembly, alteration, corrosive chemicals, improper voltage, fire, flood, negligence, accident, improperly or incorrectly performed maintenance or repair, or failure to perform necessary maintenance or repair, or if the use of this product is not in compliance with the instructions and specifications for its use.

Service
For Warranty service and parts replacement (US users only), you must:

  • Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorization) number.
  • Have original proof of purchase.
  • Use the original undamaged packaging or an industrial certified packaging method.

End user will be responsible to ship the unit (with RMA Number showing on the shipping label) to the XPOWER Service Department. XPOWER will inspect, assess and advise the repairs needed and the applicable cost, if any. For users outside the US, please contact an XPOWER Distributor in your country or region for Warranty service and parts replacement.

200 Series Parts List

Item No. Parts Name Item No. Parts Name
1 Left Housing 2 Grid Cover (Motor Side)
3 Timer & Switch Plate 4-1 & 4-2 Switch Knob & Timer Knob
5-1 & 5-2 Switch & Timer 6 Motor
7 Right Housing 8 Power Cord
9 Fan 10 Grid Cover (Fan Side)
11 Air Outlet Grid Cover 12 Kick Stand
13 Rubber Feet (Not Shown) 14 Screws and Nuts (Not Shown)
15 Capacitor

200 Series Parts List

More XPOWER products available in US market:

Air Movers
400 Series: P-400, X-400, X-400A, X-430TF
600 Series: P-600, X-600, X-600A, P-630, X-630
800 Series: P-800(H), X-800(H), X-800TF(H), P-830(H), X-830(H)

Force Dryers & Wall Dryer
B-3J, B-5J, B-5W

Blowers
BR-2C01A, BR-201A, BR-232A, BR-252A, BR-282A

Axial Fan
X-41ATR, X-42ATR

Pet Dryers
B-2, B-3, B-4, B-5, B-16, B-18, B-24, B-27, X-430TF+MDK, X-800TF+MDK 220~240V models are also available for overseas markets. Please check www.XPOWER.WS for more details…

Warranty Registration (for US user only)
For your product warranty, please complete and mail/fax this form to XPOWER MANUFACTURE, INC.
Address: 220 Clary Ave., San Gabriel, CA 91776. Tel: 626-285-3301 Fax: 626-285-3302
(For your convenience, register your product online at xpower.ws)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals