conrad SA 1200P Carbon Dioxide Detector Datalogger Function Instruction Manual

June 5, 2024
CONRAD

conrad SA 1200P Carbon Dioxide Detector Datalogger Function Instruction Manual
conrad SA 1200P Carbon Dioxide Detector Datalogger
Function

Getting Started

Thanks for purchasing our desktop CO2 monitor! This product is used to monitor CO2 concentration, humidity(RH) and temperature(TEMP) for indoor air quality monitoring.

Packing List

CO2 Monitor Unit
USB Cable for Power
User’s Manual
AC Adapter (Optional)

Features at a Glance

Large Display
Touch Button Operation
15° Bevel Design, Easy to Read
Low Drift NDIR Sensor, Long Lifespan
Audible and Visible Alarm
Chart with Variable Time Zoom Levels
CO2/RH/Temperature Monitor Tracer
Auto-Calibration and Manual Calibration
Max/Min Value Display in Certain Time

Overview

Drawing Sketch and Components List
Overview

Item Description Item Description
1 Front Panel 9 Good Level
2 LCD 10 Low Level
3 Button 11 USB Port
4 Button 12 Hole for Rope
5 Button 13 Hole for Screws
6  Button 14 Hole for Buzzer
7 Power Indicator 15 Label
8 High Level 16 Hole for Sensors

General Operation and Settings

  • Use provided USB cable to connect the device. Once the countdown is complete, your device is ready to use. See detail in Page 3.
  • Use and buttons to switch timeline and CO2/RH/TEMP. The trend chart displays the history records for any of the three parameters. See detail in Page 5.
  • To restore factory defaults, hold for 4 seconds until an audible beep is heard.
  • Press once will bring up the main menu. To select the function, press / button. See detail in Page 7.
  • Select to switch human and plants modes. See detail in Page 8.
  • Select to change the high/low alarms for human and plant . See detail in Page 11.
  • Enter to switch alarm and mute . See detail in Page 8.
  • Enter to switch temperature units C and F. See detail in Page 11.

Operating Instructions

Operating Instructions

  1. When first unboxing, plug in the unit with the provided USB cable as shown on the right.
  2. Once successfully connected, the power indicator and 3 LEDs flash one by one.
  3. Main display shows a countdown from 10.
    Once the countdown is complete, your product is ready to use. No initial setup or calibration is needed

LCD Display

LCD Display

Item Name Item Name
17 CO2/RH/TEMP Chart 23 Plant Mode
18 Max Reading of Chart 24 Human Mode
19 Min Reading of Chart 25 Audible Alarm On/Off
20 RH Reading 26 CO2 Reading
21 Temperature Reading  oC / o F 27 Time per Division- indicates the

chart’s span of time
22| Main Menu

Trend Chart Display

The below chart displays the past readings for any of the three parameters (CO2/RH /TEMP). There are 4 modes that can be toggled by using key: CO2, TEMP, RH, and Cycle(automatically cycles through CO2/TEMP/RH).
Trend Chart Display

Press will toggle the available Zoom Levels for each parameters.(Minute/Hour/ Day/Week)
Trend Chart Display

Below is a table that shows the available Zoom Levels for all parameters CO2/RH/ TEMP,as well as the duration of each division for corresponding Zoom Levels:

Zoom Level (Time Span) Time per Division
1M(minute) 5sec /div
1H(hour) 5m/div
1D(day) 2h/div
1W(week) 0.5d/div

Max/Min

At the top right corner of the display, there are two numerical indicators: MAX and MIN.As the Zoom Level is changed, the MAX and MIN values will reflect the maximum and minimum values on the chart of the selected parameter(CO2, RH and TEMP).

Main Menu Functions

Main Menu Functions
The Main Menu functions can be actived by pressing . Pressing / once will bring up the main menu, with an underlining flashing bar indicating the current choice.
Main Menu Functions

To select the function, press when it is underlined by the flashing bar. Note that after 30 seconds if nothing is pressed, the Main Menu will disappear and the device will revert to the normal state.

Function Description
ALARM ![Function](https://manuals.plus/wp-

content/uploads/2022/05/Screenshot_21-203-550x52.png)
When ALARM display , an audible alarm will sound if the CO2 level exceeds preset CO2 alarm value; means MUTE.
PLANT| Function
Select number 0 to enter human mode. 0 is defaulted as human mode, unchangeable. The preset Low and high alarm are 800 and 1200ppm. Enter “ADV” to adjust them if necessary. In plant mode, it allows user to select between types of plants for optimal setting by using / cycles through 1~9. See number references with corresponding alarm settings in High and low alarms in Page 14.
LOG| Function
This function allows the user to see historical data records.
CALI| Function
Before calibration, run this device for at least 20 minutes with windows open or in outdoor environment with portable battery source to reach an atmosphere with 400ppm CO2. Wait till the CO2 reading is stable, follow above steps for calibration. After calibration leave it 10 minutes before normal use.
ºC / ºF| Function
Use this function to toggle between Celsius ( C ) and Fahrenheit ( F ) for the temperature display.
ADV| Function
Use this function to set high and low alarm values of human mode (0) as well as the first option of plant mode (1). High and low alarms for options 2-9 under plant mode are not adjustable. See details in Page 14. (Appendix)

Specifications

Typical test conditions: Ambient Temp: 23 3°C, RH=50%~70%, Altitude= 0~10 meters

Measurement Specifications
Operating Temperature 32°F ~ 122°F (0°C ~ 50°C)
Storage Temperature -4°F ~ 140°F (-20°C ~ 60°C)
Operating & storage RH 0-95%(non-condensing)

CO2 Measurement
Measuringe range| (0-5000)ppm
Display resolution| 1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000)

Accuracy

| (0~3000)ppm: ± 50ppm ± 5% of reading (take the Maximum)
(>3000)ppm: ± 7% of reading
Repeatability| 20ppm at 400ppm
Temp compensation| ±0.1% of reading per ℃
Response time| <2 min for 63% of step change or < 4.6 min for 90% step change
Warm-up time| <20 seconds
Temperature Measurement

Operating temperature| 32°F ~ 195°F (0°C ~90°C)
Display resolution| 1°F / 0.1°C
Response time| <20 minutes (63%)
RH Measurement
Measuring range| 5~95%
Accuracy| ±5%
Display resolution| 1% Main interface display,1% Max/Min display

Operating Voltage| DC(5±0.25)V
Dimension| 1209035mm
Weight| 170g ( 6.0oz)

Appendix

No. Refers Low/High Alarm Adjustable
0, FOR Human 800-1200ppm Yes
1, FOR Customized Plant 600-900ppm Yes
2, FOR Bean 600-900ppm No
3, FOR Chillies 800-1000ppm No
4, FOR Cucumber 1000-1500ppm No
5, FOR Grape 800-1400ppm No
6, FOR Orchid 800-1400ppm No
7, FOR Potato 1200-1800ppm No
8, FOR Strawberry 800-1200ppm No
9, FOR Tomato 800-1200ppm No

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals