Thanks for purchasing our desktop CO2 monitor! This product is used to monitor CO2 concentration, humidity(RH) and temperature(TEMP) for indoor air quality monitoring.
Packing List
CO2 Monitor Unit
USB Cable for Power
User’s Manual
AC Adapter (Optional)
Features at a Glance
Large Display
Touch Button Operation
15° Bevel Design, Easy to Read
Low Drift NDIR Sensor, Long Lifespan
Audible and Visible Alarm
Chart with Variable Time Zoom Levels
CO2/RH/Temperature Monitor Tracer
Auto-Calibration and Manual Calibration
Max/Min Value Display in Certain Time
Overview
Drawing Sketch and Components List
Item | Description | Item | Description |
---|---|---|---|
1 | Front Panel | 9 | Good Level |
2 | LCD | 10 | Low Level |
3 | Button | 11 | USB Port |
4 | Button | 12 | Hole for Rope |
5 | Button | 13 | Hole for Screws |
6 | Button | 14 | Hole for Buzzer |
7 | Power Indicator | 15 | Label |
8 | High Level | 16 | Hole for Sensors |
General Operation and Settings
- Use provided USB cable to connect the device. Once the countdown is complete, your device is ready to use. See detail in Page 3.
- Use and buttons to switch timeline and CO2/RH/TEMP. The trend chart displays the history records for any of the three parameters. See detail in Page 5.
- To restore factory defaults, hold for 4 seconds until an audible beep is heard.
- Press once will bring up the main menu. To select the function, press / button. See detail in Page 7.
- Select to switch human and plants modes. See detail in Page 8.
- Select to change the high/low alarms for human and plant . See detail in Page 11.
- Enter to switch alarm and mute . See detail in Page 8.
- Enter to switch temperature units C and F. See detail in Page 11.
Operating Instructions
- When first unboxing, plug in the unit with the provided USB cable as shown on the right.
- Once successfully connected, the power indicator and 3 LEDs flash one by one.
- Main display shows a countdown from 10.
Once the countdown is complete, your product is ready to use. No initial setup or calibration is needed
LCD Display
Item | Name | Item | Name |
---|---|---|---|
17 | CO2/RH/TEMP Chart | 23 | Plant Mode |
18 | Max Reading of Chart | 24 | Human Mode |
19 | Min Reading of Chart | 25 | Audible Alarm On/Off |
20 | RH Reading | 26 | CO2 Reading |
21 | Temperature Reading oC / o F | 27 | Time per Division- indicates the |
chart’s span of time
22| Main Menu
Trend Chart Display
The below chart displays the past readings for any of the three parameters
(CO2/RH /TEMP). There are 4 modes that can be toggled by using key: CO2, TEMP,
RH, and Cycle(automatically cycles through CO2/TEMP/RH).
Press will toggle the available Zoom Levels for each parameters.(Minute/Hour/
Day/Week)
Below is a table that shows the available Zoom Levels for all parameters CO2/RH/ TEMP,as well as the duration of each division for corresponding Zoom Levels:
Zoom Level (Time Span) | Time per Division |
---|---|
1M(minute) | 5sec /div |
1H(hour) | 5m/div |
1D(day) | 2h/div |
1W(week) | 0.5d/div |
Max/Min
At the top right corner of the display, there are two numerical indicators: MAX and MIN.As the Zoom Level is changed, the MAX and MIN values will reflect the maximum and minimum values on the chart of the selected parameter(CO2, RH and TEMP).
Main Menu Functions
The Main Menu functions can be actived by pressing . Pressing / once will
bring up the main menu, with an underlining flashing bar indicating the
current choice.
To select the function, press when it is underlined by the flashing bar. Note that after 30 seconds if nothing is pressed, the Main Menu will disappear and the device will revert to the normal state.
Function | Description |
---|---|
ALARM | ![Function](https://manuals.plus/wp- |
content/uploads/2022/05/Screenshot_21-203-550x52.png)
When ALARM display , an audible alarm will sound if the CO2 level exceeds
preset CO2 alarm value; means MUTE.
PLANT|
Select number 0 to enter human mode. 0 is defaulted as human mode,
unchangeable. The preset Low and high alarm are 800 and 1200ppm. Enter “ADV”
to adjust them if necessary. In plant mode, it allows user to select between
types of plants for optimal setting by using / cycles through 1~9. See number
references with corresponding alarm settings in High and low alarms in Page
14.
LOG|
This function allows the user to see historical data records.
CALI|
Before calibration, run this device for at least 20 minutes with windows open
or in outdoor environment with portable battery source to reach an atmosphere
with 400ppm CO2. Wait till the CO2 reading is stable, follow above steps for
calibration. After calibration leave it 10 minutes before normal use.
ºC / ºF|
Use this function to toggle between Celsius ( C ) and Fahrenheit ( F ) for the
temperature display.
ADV|
Use this function to set high and low alarm values of human mode (0) as well
as the first option of plant mode (1). High and low alarms for options 2-9
under plant mode are not adjustable. See details in Page 14. (Appendix)
Specifications
Typical test conditions: Ambient Temp: 23 3°C, RH=50%~70%, Altitude= 0~10 meters
Measurement | Specifications |
---|---|
Operating Temperature | 32°F ~ 122°F (0°C ~ 50°C) |
Storage Temperature | -4°F ~ 140°F (-20°C ~ 60°C) |
Operating & storage RH | 0-95%(non-condensing) |
CO2 Measurement
Measuringe range| (0-5000)ppm
Display resolution| 1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000)
Accuracy
| (0~3000)ppm: ± 50ppm ± 5% of reading (take the Maximum)
(>3000)ppm: ± 7% of reading
Repeatability| 20ppm at 400ppm
Temp compensation| ±0.1% of reading per ℃
Response time| <2 min for 63% of step change or < 4.6 min for 90% step change
Warm-up time| <20 seconds
Temperature Measurement
Operating temperature| 32°F ~ 195°F (0°C ~90°C)
Display resolution| 1°F / 0.1°C
Response time| <20 minutes (63%)
RH Measurement
Measuring range| 5~95%
Accuracy| ±5%
Display resolution| 1% Main interface display,1% Max/Min display
Operating Voltage| DC(5±0.25)V
Dimension| 1209035mm
Weight| 170g ( 6.0oz)
Appendix
No. | Refers | Low/High Alarm | Adjustable |
---|---|---|---|
0, | FOR Human | 800-1200ppm | Yes |
1, | FOR Customized Plant | 600-900ppm | Yes |
2, | FOR Bean | 600-900ppm | No |
3, | FOR Chillies | 800-1000ppm | No |
4, | FOR Cucumber | 1000-1500ppm | No |
5, | FOR Grape | 800-1400ppm | No |
6, | FOR Orchid | 800-1400ppm | No |
7, | FOR Potato | 1200-1800ppm | No |
8, | FOR Strawberry | 800-1200ppm | No |
9, | FOR Tomato | 800-1200ppm | No |