Separett 11791-02 Incinerating Toilet Instruction Manual

June 14, 2024
Separett

Separett 11791-02 Incinerating Toilet

Product Information

Specifications

  • Manufacturer: Separett AB
  • Model: Separett Family
  • Installation Manual Languages : English, Finnish, Norwegian, Swedish
  • Recommended Distance between Air Intake and Vent Outlet: Minimum 3-4 meters

Product Usage Instructions

Installation

  1. Ensure correct installation for the product to function properly and for the warranty to apply.
  2. Follow the provided installation instructions carefully.
  3. Take into account both indoor and outdoor regulations for installation.

Regular Service
Separett Family requires regular service to ensure proper functionality. The display will indicate when it is time to service the toilet. Contact your nearest service center for assistance.

Proper Usage

  1. Only use bags provided with the toilet each time you use it.
  2. Incinerate only urine, solid waste, and toilet paper. Do not incinerate any other materials.
  3. Always push the incineration button after using the toilet.
  4. Follow the instructions for using the toilet carefully.

Additional Installation Guidelines

  • Ensure a minimum distance of 100 mm between the toilet and the wall.
  • The maximum distance above the roof should be 500 mm.

 FAQ

Q: What should I do when the display indicates it is time to service the toilet
A: Contact your nearest service center for assistance in servicing the Separett Family toilet.
Q: Can I use any bags for the toilet
A: No, only use the bags provided with the toilet for proper functionality.
Q: What materials can be incinerated in the toilet
A: Only urine, solid waste, and toilet paper should be incinerated. Do not incinerate any other materials.

WARNING: There must not be any other ventilation system, such as a fan or similar, in the space.

Separett -11791-02 -Incinerating -Toilet -FIG-2

Separett family must be installed correctly both in order for it to function, and for the warranty to apply. There are regulations both indoors and outdoors for the installation. Follow the instructions carefully.The Separett family needs regular service to function properly. You will get a message on the display when it is time to service the toilet. Contact your nearest service center.The Separett family must be used correctly to function properly. Only bags like the ones you get with the toilet should always be used each time you use the toilet and only urine, solid waste and toilet paper may be incinerated. Always push the incineration button after you have used the toilet. Use the proper incinerating program and you will save energy. Follow the instructions for using the toilet carefully.

Separett -11791-02 -Incinerating -Toilet -FIG-3

This is included

Separett -11791-02 -Incinerating -Toilet -FIG-4

  • In order for the airflow to be optimal, the 90° long bend and ventilation cowl included must be installed. The windshield is mounted by passing it about 4cm above the ventilation tube, until the edge on the inside receives. In use of another long bend or ventilation cowl, the warranty does not apply

  • The gaskets are placed on the connection on the back of the toilet. Their purpose are to fit tightly between the toilet and the vent tube to prevent air and odor should come out in the space where the toilet is placed

Separett -11791-02 -Incinerating -Toilet -FIG-6

  • To prevent the outgoing air from coming back into the space where the toilet is placed, the distance between the air intake (fresh air valve) and the vent outlet (vent cowl) should be at the minimum 3-4 meters

  • Use the supplied short connection pipe (100 mm) between the toilet and the 90° bend.

  • Max5meters in total length from the 90° bend

  • .Max 500 mm above the roof.

  • Attach the supplied hose on the drain tap on the 90° bend to divert condensation.

  • The ventilation valve is placed on an outer wall, min 160 mm Ø.

NOTE  Only Ø110 mm vent. pipes made of plastic and 1pcs 90 ° bend may be used in the installation. When installing a 90 ° bend tube directly behind the toilet, 30 cm space is required for installation behind the toilet

  • Connection pipe (horizontal) max 500 mm, install with 2° inclination backward from the toilet. Min 100 mm between the toilet and the wall.
  • Max 4,5 meters in total length from the 90° bend.
  • Max 500 mm between the 45° bends.
  • Max 500 mm above the roof.
  • A ventilation valve is placed on an outer wall. If placed directly behind the toilet, underneath the ventilation pipe, min 110 mm Ø, if placed elsewhere min 160 mm Ø.

NOTE  Only Ø110 mm vent. pipes made of plastic and 1pcs 90 ° bend may be used in the installation.

Separett -11791-02 -Incinerating -Toilet -FIG-9

  • Connection pipe (horizontal) max 500 mm, install with 2° inclination backward from the toilet. Min 100 mm between the toilet and the wall.
  • Max 5 meters in total length from the 90° bend.
  • Max 500 mm above the roof.
  • A ventilation valve is placed on an outer wall. If placed directly behind the toilet, underneath the ventilation pipe, min 110 mm Ø, if placed elsewhere min 160 mm Ø.

NOTE Only Ø110 mm vent. pipes made of plastic and 1pcs 90 ° bend may be used in the installation.

Separett -11791-02 -Incinerating -Toilet -FIG-11

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Separett User Manuals

Related Manuals