TESY Compact 10 Electric Water Heater Instruction Manual
- June 5, 2024
- TESY
Table of Contents
Compact 10 Electric Water Heater
**Instruction Manual
**
IMPORTANT RULES
- This technical description and instructions manual was prepared in order to acquaint you with the product and the conditions of proper installation and use. These instructions were also intended for use by qualified technicians, who shall perform the initial installation, or disassembly and repairs in the event of a breakdown.
- Following the current instructions will primarily be of interest to the consumer, but along with this, it is also one of the warranty conditions, pointed out in the warranty card, so that the consumer can benefit from the free warranty services. The producer is not responsible for damages in the appliance that have appeared as a result of the operation and/or installation not corresponding to the instructions here.
- The electric water heater complies with the requirements of EN 60335-1, and EN 60335-2-21. 4. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
Attention! Improper installation and connection of the appliance may make
it hazardous for the health and life of consumers. It may cause grievous and
permanent consequences, including but not limited to physical injuries and/or
death. Improper installation and connection of the appliance may also lead to
damage to the consumers’ property /damage and/ or destruction/, or to that of
third persons, as a result of, but not limited to flooding, explosion, and/or
fire. Installation, connection to the main water and power supply, and
putting into operation must be carried out by certified electricians and
technical personnel certified in the installation of this category of
appliances, who have obtained their license in the state where the
installation and commissioning of the appliance are carried out, and in
compliance with its local legislation.
** All alterations and modifications to the water heater’s construction and
electrical circuitry are forbidden. If such alterations or modifications are
established during the inspection, the appliance’s warranty shall be null and
void. Alterations and modifications shall mean each instance of removal of
elements incorporated by the manufacturer, building in of additional
components into the water heater, and replacement of elements by similar
elements unapproved by the manufacturer.
Mounting**
- The water heater must only be mounted in premises with normal fire resistance.
- In the event the device is mounted in a bathroom, the selected location must exclude the possibility of water spray contact from the showerhead or portable showerhead attachment.
- The water heater is designed to operate only in closed and heated premises where the temperature is not lower than 4°C and it is not designed to operate in a continuous protracted regime.
- The appliance is affixed to a wall by means of mounting brackets attached to the unit’s body. Two hooks are used to fix the appliance (min. Ø 4 mm) firmly on the wall (included in the mounting set).
Water heater connection
- The appliance is intended to supply hot water to household sites equipped with a piping system working at a pressure below 6 bar (0,6 Mpa).
- .The safety return valve must be mounted on the cold water supply pipe, in observance of the direction arrow stamped on its body, indicating the incoming water’s direction. Additional stopcocks must not be mounted between the safety return valve and the water heater. Exception: If the local regulations (norms) require the usage of another protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it must be bought additionally. For mechanisms operating in accordance with EN 1487, the announced operational pressure must be no more than 0.7 MPa. For other protection valves, the pressure at which they are calibrated must be 0.1 MPa lower than the one marked on the appliance’s sign. In these cases, the safety valve which the appliance is supplied with should not be used.
- The safety valve and the pipe between the valve and the water heater must be protected from freezing. During hose draining – its free end must be always open to the atmosphere (not to be immersed). Make sure that the hose is also protected from freezing.
- In order to secure the water heater’s safe operation, the safety return valve must undergo regular cleaning and inspections for normal functioning /the valve must not be obstructed/, and for the regions with highly calcareous water, it must be cleaned from the accumulated limescale. This service is not provided under warranty maintenance.
- In order to prevent injury to users and third persons in the event of faults in the system for providing hot water, the appliance must be mounted in premises outfitted with floor hydro insulation and plumbing drainage. Don’t place objects, which are not waterproof under the appliance under any circumstances. In the event of mounting the appliance in premises not outfitted with floor hydro insulation, a protective tub with plumbing drainage must be placed under the appliance.
- During operation regime of heating, the water water drops through the drainage opening of the protection valve are usual. The protection valve should be left open to the atmosphere. Measures should be taken to lead and collect the leakages in order to prevent damages.
- If the probability exists for the premise’s temperature to fall below 0°, the water heater must be drained. In the event you must empty the water heater, first, you must cut off its power supply.
Draining procedure for boilers designed to be installed ABOVE SINKS:
- First, shut the cold water supply valve
- Open the hot water valve on the mixing-faucet
- The water tap 7 (fig 4a) must be opened to drain the water from the water tank. If there is no such tap built in the pipeline than the water can be drawn directly from the inlet pipe of the water tank after when you disconnect it from the water main
Draining procedure for boilers designed to be installed UNDER SINKS:
- Switch the boiler off the power supply network.
- Dismantle the connecting water fittings from the boiler.
- Disassemble the boiler from its installation place, turn it so the pipes point to the floor, and pour the water in a vessel you have prepared for the purpose. Wait until all the water drains out of the boiler.
Connection to the electrical network
- Do not switch on the water heater unless you established it was filled with water..
- Upon connecting the water heater to the electric mains care must be taken to connect the safety lead.
- In Models without a power cord, the circuit has to be supplied with a safety fuse (16A) and with the inbuilt device to insure disconnection of all pole pieces in the conditions of over-voltage from category III.
- If the power supply cord (of models that have one) is damaged, it must be replaced by a service representative or a person with similar qualifications, to avoid any risk.
- During the heating, the appliance could produce a hissing noise (the boiling water). This is common and does not indicate any damage. The noise gets higher with time and the reason for this is the accumulation of limestone. To remove the noise the appliance must be cleaned from limestone. This type of cleaning is not covered by the warranty.
Dear Clients, The TESY team would like to congratulate you on your new purchase. We hope that your new appliance shall bring more comfort to your home.
TECHNICAL SPECIFICATIONS
-
Nominal volume V, liters – see the appliance’s rating plate
-
Nominal voltage – see the appliance’s rating plate
-
Nominal power consumption – see the appliance’s rating plate
-
Nominal pressure – see the appliance’s rating plate
ATTENTION! This is not the water mains pressure. This is the pressure that is announced for the appliance and refers to the requirements of the safety standards. -
Water heater type – closed accumulating water heater, with thermal insulation
-
Inner coating: GC-glass-ceramics
-
Daily energy consumption – see Annex I
-
Rated load profile – see Annex I
-
Quantity of mixed water at 40°C V40 litres – see Annex I
-
Maximum temperature of the thermostat – see Annex I
-
Default temperature settings – see Annex I
-
Energy efficiency during water heating – see Annex I
DESCRIPTION AND PRINCIPLE OF OPERATION
The appliance is designed to operate in regions where the water hardness is not more than 10°dH. In case it is installed in a region where the water is harder it is possible that limestone precipitation accumulates very fast. This can cause a specific noise during heating, as well as fast damaging of the electrical part. For regions with harder water yearly cleaning of the limestone precipitation in the appliance is recommended, as well as usage of not more than 2 kW of heating power The appliance consists of a body, flange, plastic control panel, and safety return valve.
-
The body consists of a steel reservoir (water tank) and plastic housing (outer shell) with thermal insulation placed in-between, and two pipes with thread G ½“, for cold water supply (marked with a blue ring) and hot water discharge(marked with a red ring). The inner reservoir is made of steel proved against corrosion by a special glass-ceramic coating
-
The flange is fitted with an electric heater and magnesium anode protector. The flange is fixed to the water tank with bolts.
The electric heater heats the water in the tank and is controlled by the thermostat, which automatically maintains the preset temperature.
The plastic control panel incorporates a switch (depending on model), an adjustable thermostat (depending on model), and thermal cut-out and control lamps.
The thermal cut-out is a device, which switches the heater off the power supply when the water temperature reaches excessive values. If this device is actuated, you should call a service station.
The signal lamps (depending on the model) on the control panel indicate the current model of the unit.
The magnesium protector provides additional anti-corrosion protection to the internal tank for heaters fitted with glass-ceramic coating. -
The safety-return valve prevents the appliance’s complete emptying in the event of a cold water supply interruption. The valve protects the appliance from pressure increases higher than the allowed value during heating (! pressure will increase when temperature increases), by releasing the excess pressure through the drain outlet. Water dropping out through the drains during the warming process is a normal event that must be taken into consideration when the boiler is installed.
ATTENTION! The safety-return valve cannot protect the appliance in the event of water mains pressure in excess of the acceptable pressure stated for the appliance.
INSTALLATION AND SWITCH ON
Attention! Improper installation and connection of the appliance may make it hazardous for the health and life of consumers. It may cause grievous and permanent consequences, including but not limited to physical injuries and/or death. Improper installation and connection of the appliance may also lead to damage to the consumers’ property /damage and/ or destruction/, or to that of third persons, as a result of, but not limited to flooding, explosion, and/or fire. Installation, connection to the main water and power supply, and putting into operation must be carried out by certified electricians and technical personnel certified in the installation of this category of appliances, who have obtained their license in the state where the installation and commissioning of the appliance are carried out, and in compliance with its local legislation.
Installation
We recommend the installation of the device at close proximity to locations where hot water is used, in order to reduce heat losses during water transportation. The selected location must exclude the possibility of water spray originating from the showerhead or other water contacts.
-
Appliances designed for installation above sinks are assembled in such a manner that the outlet/inlet pipes are pointed downwards (to the floor of the premise).
The appliance is affixed to a wall by means of mounting brackets attached to the unit’s body. Two hooks are used to fix the appliance (min. Ø 4 mm) firmly on the wall (included in the mounting set). -
Appliances designed for installation under sinks are assembled in such a manner that the outlet/inlet pipes are pointed upwards (to the ceiling of the premise).
The appliances can be placed standing on the floor or mounted on the wall. In case you want to mount the appliance on the wall, the suspension must be done with two hooks (min. Ø 4 mm) securely attached to the wall.
IMPORTANT: The type of appliance designed to be installed UNDER / ABOVE a
sink is marked on the appliance.
The bearing plank construction for boilers installed above / under sinks is
universal and allows the space between hooks to vary between 96 and 114mm.
(fig.2).
For a clear understanding of wall installation schemes, please refer to fig.2
(A above sink, B under sink, and C for floor installation).
ATTENTION! In order to prevent injury to user and third persons in the
event of faults in the hot water supply system, the appliance must be mounted
in premises outfitted with floor hydro insulation and sewer drainage. Don’t
place objects, which are not waterproof under the appliance under any
circumstances. In the event of mounting the appliance in premises without
floor hydro insulation, a protective tank with a sewer discharge drainage must
be placed under the appliance.
Notice: the set does not include a protective tub and the user must
select the same.
2. Water heater connection to the water supply system Fig.4a – installation
scheme above sink Fig.4b – installation scheme under sink
Where: 1 – input pipe, 2 – safety valve (0.8 MPa), 3 – reduction valve (if the
water supply pressure exceeds 0,6 MPa), 4 – stop valve, 5 – bell-mouth
discharge to the sewer, 6 – hose; 7 – Drain water tap. Upon connecting the
water heater to the water supply the system, take care of the indicative color
markings /rings/ of the pipes:
BLUE – for cold /in-flowing/ water,
RED – for hot /out-flowig/ water.
The mounting of the safety return valve supplied with the water heater is
obligatory. The safety return valve must be installed on the cold water supply
pipe, according to
the arrow stamped on its body indicates the supplied water direction.
Exception: If the local regulations (norms) require the usage of another
protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it
must be bought additionally. For mechanisms operating in accordance with EN
1487, the announced operational pressure must be no more than 0.7 MPa. For
other protection valves, the pressure at which they are calibrated must be 0.1
MPa lower than the one marked on the appliance’s sign. In these cases, the
safety valve which the appliance is supplied with should not be used.
ATTENTION! Another type of stopping armature is not allowed between the
protection return valve (the protective device) and the appliance.
ATTENTION! Any other /old/ safety return valves may lead to a failure of
your appliance, therefore they must be removed.
ATTENTION! Fixing the safety return valve to threads longer than 10 mm is
not allowed, as it could damage the valve and could make the use of your
appliance dangerous.
ATTENTION! The safety valve and the pipe between the valve and the water
heater must be protected from freezing. During hose draining – its free end
must be always open to the atmosphere (not to be immersed). Make sure that the
hose is also protected from freezing.
The boiler is filled with water by opening the tap on the cold water supply
system and the tap on the hot water mixing faucet. After the filling process
is complete, a constant
stream of water should flow from the water-mixing faucet. Now you can shut the
hot water tap on the mixing faucet. When you must empty the water heater, you
should first cut it off the power supply.
Draining procedure for boilers designed to be installed ABOVE SINKS:
- First shut the cold water supply valve
- Open the hot water valve on the mixing-faucet
- The water tap 7 (fig 4a) must be opened to drain the water from the water tank. If there is no such tap built in the pipeline, then the water can be drawn directly from the inlet pipe of the water tank after when you disconnect it from the water main
IMPORTANT: When draining the boiler, take measures to prevent damages
caused by the flowing water.
Draining procedure for boilers designed to be installed UNDER SINKS:
- Switch the boiler off the power supply network.
- Dismantle the connecting water fittings from the boiler.
- Disassemble the boiler from its installation place, turn it so the pipes point to the floor, and pour the water in a vessel you have prepared for the purpose. Wait until all the water drains out of the boiler.
In case the pressure in the water mains is over the value pointed out in the
above paragraph I, then it is necessary to assemble a pressure reduction
valve, otherwise, the water heater would not function properly. The
Manufacturer does not assume any liability for problems arising out of the
appliance’s improper use.
Water heater’s electrical connection (fig.3)
ATTENTION! Before you switch the power supply, make sure the appliance is
full of water.
3.1. Models fit with power supply cord combined with a plug shall be plugged
in a socket. The boiler can be disconnected from the power supply by
unplugging.
ATTENTION! The wall plug must be properly connected to a separate
electrical circle that is provided with a protector. It must be earthed.
3.2. Water heaters fitted with a supply cord without a plug
The appliance has to be connected to a separate electrical circuit of the
stationary electrical wiring. The connecting has to be constant- with no plug
contacts. The circuit has to be supplied with a safety fuse (16A) (20A for
power > 3700W) and with the inbuilt device to insure disconnection of all pole
pieces in the conditions of over-voltage from category III.
The connecting of the conductors of the supply cord of the appliance has to be
carried out as follows:
- conductor with brown insulation – to the phase conductor of the electrical wiring (L)
- conductor with blue insulation- to the neutral conductor of the wiring (N)
- conductor with yellow-green insulation – to the safety conductor of the wiring ( )
3.3. Models without power supply cord
The appliance has to be connected to a separate electrical circuit of the
stationary electrical wiring. The circuit has to be supplied with a safety
fuse 16A. Copper single core (rigid– nonstranded) conductor shall be used for
the connection– cable 3 x 1.5 mm2 for power 2000 W. The electrical circuit
supplying the appliance must have an in-built device ensuring the splitting of
all terminal poles under conditions of super-voltage of category III.
In order to fix the power cable to the water heater, it is necessary to remove
the plastic cover (fig.5). The power leads connections must be in accordance
with the terminal markings of the thermal circuit breaker:
- the phase cable must be connected to the A1 (11) terminal
- the neutral, to the B1 (21) terminal
- and the protection terminal, obligatory to the marked screwed joint
The power supply cord can be fixed to the plastic control panel with a cable
stop. After the installation, the plastic cover must be replaced in its
original position!
Explanations to Fig.3:
T1 – thermal regulator, T2 – thermal circuit breaker, IL1 light indicator, R –
heater
OPERATING THE DEVICE
Before the initial start of the device, please make sure that the water heater
has been correctly connected to the electrical network and that it is filled
up with water. Switching on the water heater is done through the device
incorporated in the installation, which is described in the subitem
3.2 of paragraph V, or by inserting the plug into an electrical socket (for
models with a cord with a plug).
Clarification to Fig.6: Operation modes:
-
Position ( ) anti-freezing mode
WARNING: The electrical power supply of the device should be switched on. The safety valve and the pipe connecting it to the device must be secured against freezing. -
Position ( ) maximum temperature
-
Position ( ) at this mode the water temperature reaches about 60°С. In this way, heat losses are reduced.
-
Light indicator – at heating mode, it is lit in red, and it is lit in blue when the water has been heated up and the thermostat has switched off.
-
Regulator knob – for temperature setting
Water heaters with the electrical-mechanical POP-UP operation:
- Push the knob to pop-up Fig. 7а.
- Set the temperature of the water heater Fig. 7b This setting allows for gradual temperature adjustment.
- Push the knob to retract Fig. 7c
WARNING! Once a month set the knob to the position ‘maximum temperature’ for a period of 24 hours (unless the device is constantly operated in this mode). Thus you will ensure better hygiene of the heated water.
RUST PROTECTION MAGNESIUM ANODE
The magnesium anode protects the water tank’s inner surface from corrosion. The anode element is an element undergoing wear and tear and is subject to periodic replacement. This is the cost for the user. In view of the long-term and accident-free use of your water heater, the manufacturer recommends periodic inspections of the magnesium anode’s condition by a qualified technician and replacement whenever required, and this could be performed during the appliance’s technical preventive maintenance. For replacements, please contact the authorized service stations!
PERIODIC MAINTENANCE
Under normal use of the heater, under the influence of high temperature,
limescale /the so-called limescale layer/ is deposited upon the heating
element’s surface. This worsens
the heat exchange between the heating element and water. The heating element’s
surface temperature increases along /with boiling water/. The thermoregulator
begins to switch on and off more frequently. A ‘’deceptive” activation of the
thermal protection is possible. Due to these facts, the manufacturer
recommends preventive maintenance of your water heater every two years by an
authorized service center or service base. This protective maintenance must
include cleaning and inspection of the anode protector (for water heaters with
glass-ceramic coating), which shall be replaced with a new one if the need
arises.
In order to clean the appliances use a damp cloth. Do not clean with abrasive
or solvent content detergents. Do not pour water over the appliance.
The manufacturer does not bear the responsibility for all consequences
caused by not obeying the instructions, given hereby.
Environmental protection instructions.
Old electric appliances contain precious materials and must not be disposed of
with domestic waste! Please make your active contribution to the protection of
the environment and dispose of the appliance in the stations organized for the
purpose (if available).