TESY 72-74 Electric Water Heater Instructions

May 15, 2024
TESY

TESY 72-74 Electric Water Heater

Specifications:

  • Model: Electric Water Heater
  • Pressure : Maximum 6 bars (0.6 MPa)
  • Power : 220-310V
  • Capacity Options :
    • 1a, 1b, 1c : 6-7 liters
    • 1d, 1e : 9-10 liters
    • 1h, 1g : Customizable

Product Usage Instructions

Installation:

1. Locate a suitable place for installation ensuring proper ventilation.

2. Connect the water heater to a power source following the electrical requirements.

Operation:

3. To start using the water heater, turn on the power switch.

4. Adjust the temperature settings as per your preference.

Maintenance:

5. Regularly check for any leaks or malfunctions.

6. Clean the water heater periodically to prevent buildup.

FAQ

  • Q: What is the maximum pressure this water heater can withstand?
    • A : The water heater can handle a maximum pressure of 6 bars (0.6 MPa).
  • Q: What is the recommended power supply for this water heater?
    • A : The water heater operates on a 220-310V power supply.

TOOLS AND DIMENSIONS

TESY-72-74-Electric-Water-Heater-FIG14

INSTALLATION INSTRUCTIONS

TESY-72-74-Electric-Water-Heater-FIG18 TESY-72-74-Electric-Water-Heater-FIG19

IMPORTANT RULES

  1. This technical description and instructions manual was prepared in order to acquaint you with the product and the conditions of proper installation and use. These instructions were also intended for use by qualified technicians, who shall perform the initial installation, or disassembly and repairs in the event of a breakdown.
  2. Following the current instructions will primarily be of interest to the consumer, but along with this, it is also one of the warranty conditions, pointed out in the warranty card, so that the consumer can benefit from the free warranty services. The producer is not responsible for damages in the appliance that have appeared as a result of operation and/or installation not corresponding to the instructions here.
  3. The electric water heater complies with the requirements of EN 60335-1, and EN 60335-2-21.
  4. This appliance can be used by children aged from 3 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
  5. Children shall not play with the appliance.
  6. Children aged from 3 to 8 years are only allowed to operate the tap connected to the water heater.
  7. Children shall not make cleaning and user maintenance without supervision.

Attention! Improper installation and connection of the appliance may make it hazardous for the health and life of consumers. It may cause grievous and permanent consequences, including but not limited to physical injuries and/or death. Improper installation and connection of the appliance may also lead to damage to the consumers’ property /damage and/ or destruction/, or to that of third persons, as a result of, but not limited to flooding, explosion, and/or fire.

Installation, connection to the main water and power supply, and putting into operation must be carried out by certified electricians and technical personnel certified in the installation of this category of appliances, who have obtained their license in the state where the installation and commissioning of the appliance are carried out, and in compliance with its local legislation.

All alterations and modifications to the water heater’s construction and electrical circuitry are forbidden. If such alterations or modifications are established during inspection, the appliance’s warranty shall be null and void. Alterations and modifications shall mean each instance of removal of elements incorporated by the manufacturer, building in of additional components into the water heater, and replacement of elements by similar elements unapproved by the manufacturer.

Mounting

  1. The water heater must only be mounted in premises with normal fire resistance.
  2. In the event the device is mounted in a bathroom, the selected location must exclude the possibility of water spray contact from the showerhead or portable showerhead attachment.
  3. The water heater is designed to operate only in closed and heated premises where the temperature is not lower than 4°C and it is not designed to operate in a continuous protracted regime.
  4. The appliance is affixed to a wall via the mounting brackets attached to the unit’s body (if the brackets are not attached to the unit’s body, they must be affixed in place via the provided bolts).

Water heater connection

  1. The appliance is intended to supply hot water to household sites equipped with a piping system working at a pressure below 6 bar (0,6 Mpa).
  2. The safety return valve must be mounted on the cold water supply pipe, in observance of the direction arrow stamped on its body, indicating the incoming water’s direction. Additional stopcocks must not be mounted between the safety return valve and the water heater. Exception: If the local regulations (norms) require the usage of another protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it must be bought additionally. For mechanisms operating in accordance with EN 1487 the announced operational pressure must be no more than 0.7 MPa. For other protection valves, the pressure at which they are calibrated must be 0.1 MPa lower than the one marked on the appliance’s sign. In these cases the safety valve which the appliance is supplied with should not be used.
  3. The safety valve and the pipe between the valve and the water heater must be protected from freezing. During hose draining – its free end must be always open to the atmosphere (not to be immersed). Make sure that the hose is also protected from freezing.
  4. In order to secure the water heater’s safe operation, the safety return valve must undergo regular cleaning and inspections for normal functioning /the valve must not be obstructed/, and for the regions with highly calcareous water, it must be cleaned from the accumulated lime scale. This service is not provided under warranty maintenance.
  5. In order to prevent injury to the user and third persons in the event of faults in the system for providing hot water, the appliance must be mounted in premises outfitted with floor hydro insulation and plumbing drainage. Don’t place objects, which are not waterproof under the appliance under any circumstances. In the event of mounting the appliance in premises not outfitted with floor hydro insulation, a protective tub with plumbing drainage must be placed under the appliance.
  6. During operation – the regime of heating the water – water drops through the drainage opening of the protection valve are usual. The protection valve should be left open to the atmosphere. Measures should be taken to lead and collect the leakages in order to prevent damage.
  7. If the probability exists for the premise’s temperature to fall below 0°С, the water heater must be drained. In the event you must empty the water heater, first, you must cut off its power supply. The inflow of water from the water mains must first be terminated and the hot water tap of the mixing faucet must be opened. The water tap 7 (fig 3) must be opened to drain the water from the water tank. If there is no such tap built in the pipeline, then the water can be drained directly from the inlet pipe of the water tank after when you disconnect it from the water main.
  8. These instructions shall also apply to water heaters equipped with a heat exchanger – Section VII. These are appliances with inbuilt heat exchangers and are intended to be connected to the heating system with a maximum temperature of the heat carrier of 80°C.

Connection to the electrical network

  1. Do not switch on the water heater unless you establish it was filled with water..
  2. Upon connecting the water heater to the electric mains care must be taken to connect the safety lead.
  3. For models without a power cord, the circuit has to be supplied with a safety fuse (16A) and with the inbuilt device to ensure disconnection of all pole pieces in the conditions of over-voltage from category III.
  4. If the power supply cord (of models that have one) is damaged, it must be replaced by a service representative or a person with similar qualifications, to avoid any risk.
  5. For water heaters intended for horizontal mounting the power supply conductor insulation from fixed wiring must be protected from direct contact with the flange (in the zone under the plastic panel). For example, insulating sleeving having a temperature rating higher than 90 °C can be used.
  6. During the heating, the appliance could produce a hissing noise (the boiling water). This is common and does not indicate any damage. The noise gets higher with the time and the reason for this is the accumulation of limestone. To remove the noise the appliance must be cleaned from limestone. This type of cleaning is not covered by the warranty.

Dear Clients,

The TESY team would like to congratulate you on your new purchase. We hope that your new appliance shall bring more comfort to your home.

TECHNICAL PARAMETERS

  1. Nominal volume V, liters – see the appliance’s rating plate
  2. Nominal voltage – see the appliance’s rating plate
  3. Nominal power consumption – see the appliance’s rating plate
  4. Nominal pressure – see the appliance’s rating plate
    • This is not the water mains pressure. This is the pressure that is announced for the appliance and refers to the requirements of the safety standards.
  5. Water heater type – closed type accumulating water heater, with thermal insulation
    • For models without heat exchanger (coil)
  6. Daily energy consumption – see Annex I
  7. Rated load profile – see Annex I
  8. Quantity of mixed water at 40°C V40 liters – see Annex I
  9. Maximum temperature of the thermostat – see Annex I
  10. Default temperature settings – see Annex I
  11. Energy efficiency during water heating – see Annex I
    • For models with heat exchanger (coil)
  12. Storage volume in liters – see Annex II
  13. Standing loss – see Annex II

DESCRIPTION AND PRINCIPLE OF WORK

The appliance is designed to operate in regions where the water hardness is not more than 10°dH. In case that it is installed in a region where the water is harder limestone precipitation may accumulate very fast. This can cause a specific noise during heating, as well as fast damage of the electrical part. For regions with harder water yearly cleaning of the limestone precipitation in the appliance is recommended, as well as usage of not more than 2 kW of heating power.
The appliance consists of a body, a flange at the bottom side /for water heaters intended for vertical mounting/ or at the sides /for water heaters intended for horizontal mounting/, protective plastic panel safety-return valve.

  1. The body consists of a steel reservoir (water tank) and housing (outer shell) with thermal insulation placed in-between made of ecologically clean high-density polyurethane foam, and two pipes with thread G ½ ‘’ for cold water supply (marked by a blue ring) and hot water outlet pipe (marked by a red ring).
  • * The inner tank may be of two types depending on the model:
  1. * Made of steel protected from corrosion by a special glass-ceramics coating
    • Made of stainless steel
      The vertical water heaters may be outfitted with a built-in heat exchange unit (serpentine tube). The heat exchanger’s entrance and exit are located at the sides and represent pipes with thread G ¾ ‘’.
  2. The flange is outfitted with an electric heater and thermostat. The water heaters with glass-ceramics coating are outfitted with a magnesium protector.
    The electric heater is used for heating the water in the tank and is managed by the thermostat, which automatically maintains the set temperature.
    The thermostat has a built-in overheating safety device, which switches of power to the heater when the water temperature reaches excessive values.

  3. The safety-return valve prevents the appliance’s complete emptying in the event the cold water supply is interrupted. The valve protects the appliance from pressure increases higher than the allowed value during heating (! pressure increases upon an increase of temperature), via the release of excess pressure during the drainage opening.

    • The safety-return valve cannot protect the appliance in the event of water mains pressure in excess of the acceptable pressure stated for the appliance

MOUNTING AND SWITCHING ON

Attention! Improper installation and connection of the appliance may make it hazardous for the health and life of consumers. It may cause grievous and permanent consequences, including but not limited to physical injuries and/or death. Improper installation and connection of the appliance may also lead to damage to the consumers’ property /damage and/ or destruction/, or to that of third persons, as a result of, but not limited to flooding, explosion and/or fire. Installation, connection to the main water and power supply, and putting into operation must be carried out by certified electricians and technical personnel certified in the installation of this category of appliances, who have obtained their license in the state where the installation and commissioning of the appliance are carried out, and in compliance with its local legislation.

Notice : The installation of the unit is at the buyer’s expense.

Mounting

TESY-72-74-Electric-Water-Heater-FIG3 TESY-72-74-Electric-Water-Heater-FIG4 TESY-72-74-Electric-Water-Heater-FIG5

TESY-72-74-Electric-Water-Heater-FIG7 TESY-72-74-Electric-Water-Heater-FIG8 TESY-72-74-Electric-Water-Heater-FIG9

TESY-72-74-Electric-Water-Heater-FIG10 TESY-72-74-Electric-Water-Heater-FIG12 TESY-72-74-Electric-Water-Heater-FIG13

  • We recommend the mounting of the device at close proximity to locations where hot water is used, in order to reduce heat losses during transportation. In the event the device is mounted in a bathroom, the selected location must exclude the possibility of water spray contact from the showerhead or portable showerhead attachment.

  • The appliance is affixed to a wall via the mounting brackets attached to the unit’s body (if the brackets are not attached to the unit’s body, they must be affixed in place via the provided bolts). Two hooks are used for suspending the appliance (min. Ø 10 mm) set firmly in the wall (not included in the mounting set). The mounting bracket’s construction designed for water heaters intended for vertical mounting is universal and allows a distance between the hooks of 220 to 310 mm (fig. 1a, 1b,1c). For water heaters intended for horizontal mounting, the distances between the hooks vary for the different models and are specified in the tabl. 6 and 7 to Fig. 1d, 1e. For water heaters intended for floor installation – tabl.6,7 2 to Fig. 1h, 1g

  • In order to prevent injury to the user and third persons in the event of faults in the system for providing hot water, the appliance must be mounted in premises outfitted with floor hydro insulation and plumbing drainage. Don’t place objects, which are not waterproof under the appliance under any circumstances. In the event of mounting the appliance in premises not outfitted with floor hydro insulation, a protective tub with plumbing drainage must be placed under the appliance.

  • Notice : the set does not include a protective tub and the user must select the same

  • Water heater connection to the pipe network.
    Fig. 3:

  • Where : 1 – Inlet pipe; 2 – Safety valve; 3 – reducing valve (for water main pressure > 0,6 MPa); 4 – Stop valve; 5 – Funnel connected to the sewer network; 6 – Hose; 7 – Drain water tap.
    Upon connecting the water heater to the water mains you must consider the indicative color markings /rings/ affixed to the pipes: blue for cold/incoming/ water, red for hot /outgoing/ water.

  • The mounting of the safety return valve supplied with the water heater is obligatory. The safety return valve must be mounted on the cold water supply pipe, in observance of the direction arrow stamped on its body, indicating the incoming water’s direction. Additional stopcocks must not be mounted between the safety return valve and the water heater.

  • Exception : If the local regulations (norms) require the usage of another protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it must be bought additionally. For mechanisms operating in accordance with EN 1487 the announced operational pressure must be no more than 0.7 MPa. For other protection valves, the pressure at which they are calibrated must be 0.1 MPa lower than the one marked on the appliance’s sign. In these cases, the safety valve which the appliance is supplied with should not be used.

  • The presence of other /old/ safety return valves may lead to a breakdown of your appliance and they must be removed.

  • Another type of stopping armature is not allowed between the protection return valve (the protective device) and the appliance.

  • The attaching of the safety return valve to threads longer than 10 mm is not allowed, otherwise this may damage the valve and pose a danger for your appliance

  • With appliances for vertical assembly, the safety valve has to be connected to the ongoing pipe with the safety plastic panel of the appliance being taken off.

  • The safety valve and the pipe between the valve and the water heater must be protected from freezing. During hose draining – its free end must be always open to the atmosphere (not to be immersed). Make sure that the hose is also protected from freezing.

  • Opening the cold-water stopcock of the water supply piping network and opening the hot-water stopcock of the water-mixing faucet carry out the filling of the water heater with water. After the filling is complete, a constant stream of water must begin to flow from the water-mixing faucet. Now you can close the hot water stopcock.

  • In the event you must empty the water heater, first, you must cut off its power supply. The inflow of water from the water mains must first be terminated and the hot water tap of the mixing faucet must be opened. The water tap 7 (fig3)  must be opened to drain the water from the water tank. If there is no such build in the pipeline, then the water can be drained directly from the inlet pipe of the water tank after when you disconnect it from the water main.

  • In the event of removing the flange, the discharge of several liters of water, which remain in the water tank, is normal.

  • Measures must be undertaken to prevent damage from discharging water during draining

  • In case that the pressure in the water mains is over the value pointed out in the above paragraph I, then it is necessary to assemble a pressure reduction valve, otherwise, the water heater would not function properly. The Manufacturer does not assume any liability for problems arising out of the appliance’s improper use.

Water heater connection to the electrical network

  • Make sure the appliance is full of water prior to switching on the electrical mains power
  • Models with a power cord with a plug are connected by inserting the plug into a contact. They are switched off the power supply by drawing the plug out of the contact.
  • The wall plug must be properly connected to a separate electrical circle that is provided with a protector. It must be earthed.

The appliance has to be connected to a separate electricity circuit of the stationary electrical wiring. The connecting has to be constant- with no plug contacts. The circuit has to be supplied with a safety fuse (16A) and with the inbuilt device to ensure disconnection of all pole pieces in the conditions of over-voltage from category III.
The connecting of the conductors of the supply cord of the appliance has to be carried out as follows:

  • conductor with brown insulation – to the phase conductor of the electrical wiring (L)
  • conductor with blue insulation- to the neutral conductor of the wiring (N)
  • conductor with yellow-green insulation – to the safety conductor of the wiring

Models without power cord

The appliance has to be connected to a separate electricity circuit of the stationary electrical wiring. The circuit has to be supplied with a safety fuse 16A (20A for power > 3700W). Copper single core (rigid – nonstranded) conductor shall be used for the connection – cable 3 x 2.5 mm² (cable 3 x 2.5 mm² for power > 3700W). The electrical circuit supplying the appliance must have an in-built device ensuring the splitting of all terminal poles under conditions of super-voltage of category III.
To install the power supply wire to the appliances remove the plastic cover.
Connect the power wires in compliance with the marks on the terminals, as follows:

  • the phase – to mark A, A1, L or L1;
  • the neutral – to N (B or B1 or N1)
  • The safety wire must be obligatory connected to the screw joint marked with

After the installation, put the plastic cover back in its place! Explanations to Fig. 2:
TS – thermal switch; TR – thermal regulator; S – switch (for models that have one); R – heater; IL – light indicator; F – flange; KL – luster terminal;

RUST PROTECTION MAGNESIUM ANODE (FOR WATER HEATERS WITH WATER TANKS COVERED BY GLASS-CERAMICS COATING)

The magnesium anode protects the water tank’s inner surface from corrosion. The anode element is an element undergoing wear and tear and is subject to periodic replacement.
In view of the long-term and accident-free use of your water heater, the manufacturer recommends periodic inspections of the magnesium anode’s condition by a qualified technician and replacement whenever required, and this could be performed during the appliance’s technical preventive maintenance.
For replacements, please contact the authorized service stations!

OPERATION

Switch on:

Before switching on the appliance for the first time, make sure that the water heater is properly connected to the power supply network and full with water.
The appliance is switched on by a switch integrated into the installation, described in item 3.3 of Section IV, or upon connecting the plug to the electrical contact (in the case of an extension cable with a plug).
Notice: Models with a built-in switch – it is necessary to switch it on. There is an embossed marking on the button of the electrical switch 1.

Water heaters with electromechanical control

TESY-72-74-Electric-Water-Heater-FIG16

Fig. 2a and 2b where :

  1. Electrical switch button (for models with а switch)
  2. Light indicators
  3. Thermostat control knob (only for models with adjustable thermostat)
    • Push and release the button in order to switch on the electrical switch. If it lightens, this means that it is switched on. The button lights constantly unless the switch is switched off or the appliance power supply from electrical main is switched off. The light indicators lighten too (see item 2.1. below).
    • In order to switch off the electrical switch, push and release the button again. It must stop to light if it is switched off. The light indicators stop lighting too.

Light indicators

The indicator light in red color – means that the appliance is in heating mode
The indicator light in blue color – means that the water is warmed and the thermostat is switched off, because the set temperature is reached

The light indicators do not light when:

  • The electrical switch of the appliance is switched off
  • The appliance power supply from electrical main is switched off
  • Protection according to the temperature is switched off – see item 4 below 2.2. Temperature setup (for models with adjustable thermostats)
    This setup allows the gradual setting of the desired temperature, achieved by using a handle on the control panel. Turn the knob to the upward indication, in order to increase the temperature of the hot water

Place the thermostat knob in position for maximum temperature (unless it is on this position constantly), for period of one day each month – see Annex-I Maximum temperature of the thermostat. This ensures higher hygiene of the used hot water.

IMPORTANT : Models that do not have thermostat control knobs have automatic water temperature preset by the manufacturer – see Annex-I Default temperature settings.

Position e(Energy-save mode) – At this mode, the water temperature reaches up to approximately 60°С. Heat losses are reduced in this way.

Аnti-freezing function

Place the thermostat knob in position „Аnti-freezing“ according to fig. 2.With this setup the device maintains a temperature that does not allow the water to freeze in it.

The electrical supply of the appliance should be turned on and so must be the appliance. The safety valve and the pipe between the valve and theappliance must be protected from freezing. In case that for some reason the electrical supply is cut off, there is a risk of freezing of the water in the water tank. For this reason, we recommend draining the water out of the appliance before long absences (longer than a week).

Protection according to the temperature (valid for all models).

The appliance is equipped with a special facility (thermal circuit-breaker) for protection against overheating of the water, which is switching off the heater from the electricity network, when the temperature reaches too high values.

When this device operates, it does not self-reset and the appliance will not work. Please call an authorized service to solve the problem.

When this device operates, it does not self-reset and the appliance will not work. Please call an authorized service to solve the problem.

MODELS EQUIPPED WITH A HEAT EXCHANGER (SERPENTINE TUBE).

These are appliances with inbuilt heat exchangers and are intended to be connected to the heating system with a maximum temperature of the heat carrier of 80°C. The control over the flow through the heat exchanger is a matter of solution for the particular installation, whereby the choice should be made at its design (e.g. external thermostat that measures the temperature in the water tank and operates a circulation pump or a magnet valve).
Water heaters with a heat exchanger provide the opportunity for the water to be heated in two ways:

  1. by means of a heat exchanger (coil) – a primary way of heating the water,
  2. by means of an auxiliary electrical heating element with automatic operation, built in the appliance – it is used only when additional heating of the water is needed or in case of repairs to the system of the heat exchanger (coil). The proper way of connecting the appliance to the electric network and how to work with it has been specified in the previous paragraphs.

Mounting:

In addition to the mounting manner outlined above, especially for the latter models, it shall be required to connect the heat exchanger to the heating installation. The connections are to be carried out in observance of the direction indicated by the arrows on Fig. 1d÷Fig. 1f.

  • Technical parameters (table 5):
  • Surface of serpentine [m²] – S;
  • Volume of serpentine [l] – V;
  • Operational pressure of serpentine [MPa] – P;

Maximum temperature of heat carrier [°C] – TmaxWe recommend you mount stopcocks at the heat exchanger’s entry and exit points. By stopping the flow of the thermophore via the lower (stopcock) you shall avoid the unnecessary circulation of the thermophore during periods of use only of the electric heating element. Upon disassembly of you water heater equipped with a heat exchanger, you must close both stopcocks.

There is a connexion with the internal thread of ½” welded to the water tank for the purposes of installing a thermal probe – marked with „TS”. Theappliance is fitted with a brass pocket for a thermal probe which should be screwed into the aforesaid connexion.

The usage of dielectric bushings for connecting the heat exchanger to an installation of copper pipes is obligatory.
To ensure minimal corrosion, pipes with limited diffusion of gasses must be used in the installation

PERIODIC MAINTENANCE

Under normal use of the heater, under the influence of high temperature, lime scale /the so-called limescale layer/ is deposited upon the heating element’s surface. This worsens the heat exchange between the heating element and water. The heating element’s surface temperature increases along /of boiling water/. The thermoregulation begins to switch on and off more frequently. A ‘’deceptive” activation of the thermal protection is possible. Due to these facts, the manufacturer recommends preventive maintenance of your water heater every two years by an authorized service center or service base. This protective maintenance must include cleaning and inspection of the anode protector (for water heaters with glass-ceramic coating), which shall be replaced with a new one if the need arises.In order to clean the appliances use a damp cloth. Do not clean with abrasive or solvent-content detergents. Do not pour water over the appliance. The manufacturer does not bear the responsibility for all consequences caused by not obeying the instructions, given hereby.

Instructions for protecting the environment

Old electric appliances contain precious materials and thus should not be thrown together with the household litter. We kindly ask you to make your active contribution for protecting the resources and the environment by handing over the appliance in the authorized buy-back stations (if such exist