Product Specifications

Model| Capacity (L)| Net Weight (kg)| Insulation (mm)| Heat Exchanger Surface S1| Heat Exchanger Capacity S1 (L)| Heat Exchanger Surface S2| Heat Exchanger Capacity S2 (L)| Heat Losses T45K (W)| Energy Efficiency Class| Maximum Operational Temperature| Rated Pressure (bar)
---|---|---|---|---|---|---|---|---|---|---|---
Tesy EV 7/5 S2| 189| 71| 50| 0.76| 4.50| 0.55| 3.20| 59| B| 8

Product Usage Instructions

Installation and Connection
Follow the provided example of installation and connection for the specific model you have.

Operation

  1. Make sure the cold water inlet and hot water outlet are correctly connected.
  2. Set the thermoregulator to your desired temperature.
  3. Monitor the thermometer for temperature readings.
  4. If applicable, adjust the electric element settings.

Maintenance:

  1. Regularly check for leaks or unusual noises.
  2. Clean the heat exchangers and service openings as needed.
  3. Replace magnesium anodes according to manufacturer recommendations.

INDIRECTLY HEATED WATER TANK
with 45° ANGLED INLETS AND OUTLETS

IHWT | 45° angled inlets and outlets

TESY developed a new range of indirectly heated water tanks with 45° angled inlets and outlets for EASY AND CONVINIENT INSTALLATION.
Suitable for NEW INSTALLATIONS and RENOVATIONS of existing systems. Specially designed for mounting in narrow spaces with an EASY ACCESS to all openings for maintenance.

Wide range from 200 L to 2000 L models of FLOOR-STANDING storage tanks for domestic hot water. Compatible for usage in single and multi-family residential buildings, as well as offices, leisure and industrial premises.

  • SPACE SAVING. Specially designed for narrow spaces, such as small technical rooms, corner areas or under stairs.
  • High-quality ENAMEL COATING with TESY CrystalTech PRO technology.
  • TWO HEAT EXCHANGERS for connection to RENEWABLE ENERGY SOURCES, such as solar panels or other heat sources.
  • LOW POSITION of the LOWER HEAT EXCHANGER to ensure efficient water heating in the cold section of the tank.
  • MAGNESIUM ANODE PROTECTION of the inner tank surface for extended product life:
    • ONE MG+ anode for the model 200 L
    • TWO MG+ anodes for the models from 300 L to 1000 L
    • THREE MG+ anodes for the models of 1500 L and 2000 L
  • HIGHLY EFFICIENT INSULATION* for minimal heat losses.
  • SERVICE OPENING for easy inspection and maintenance.
  • Option for INSTALLATION of electric HEATING ELEMENTS with different power ratings. Thermoregulator installation pocket.
  • Pockets for thermo sensors.
  • Thermoindicator.

CFC-free PU foam for models up to 500 L and optimized polyester insulation for the models from 800 L to 2000 L.

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-1

EXAMPLE OF INSTALLATION AND CONNECTION

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-2

IHWT | 45° angled inlets and outlets

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-10

  • outlet – inlet temperature of the heat transfer fluid
  • 10℃ – cold water temperature, 60℃ – hot water temperature (domestic water)

IHWT | 45° angled inlets and outlets

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-3

*200 L – 500 L**

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-4

800 L – 2000 L**

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-5

IHWT | 45° angled inlets and outlets

MODELS

| TESY EV 7/5 S2 200 60 45D| TESY EV 10/7 S2 300 65 45D| TESY EV 15/7 S2 500 75 45D| TESY EV 12/9 S2 800 99 45D| TESY EV 13/7 S2 1000 105 45D| TESY EV 12/8 S2 1500 120 45D| TESY EV 14/9 S2 2000 130 45D
---|---|---|---|---|---|---|---
CW| Cold water inlet| G1| G1| G1| G1 1/2| G1 1/2| G2| G2
HW| Hot water outlet| G1| G1| G1| G1 1/2| G1 1/2| G2| G2
IS1| Heat exchanger inlet| G1| G1| G1| G1 1/2| G1 1/2| G1 1/2| G1 1/2
OS1| Heat exchanger outlet| G1| G1| G1| G1 1/2| G1 1/2| G1 1/2| G1 1/2
IS2| Heat exchanger inlet| G1| G1| G1| G1| G1| G1 1/2| G1 1/2
OS2| Heat exchanger outlet| G1| G1| G1| G1| G1| G1 1/2| G1 1/2
R| Recirculation| G3/4| G3/4| G3/4| G3/4| G3/4| G1 1/2| G1 1/2
T| Thermometer| Ø 14×1.5| Ø 14×1.5| Ø 14×1.5| Ø 14×1.5| Ø 14×1.5| Ø 14×1.5| Ø 14×1.5
TR| Opening for thermoregulator|

G1/2

|

G1/2

|

G1/2

|

G1/2

|

G1/2

|

G1/2

|

G1/2

TS1| Thermo pocket level 1| G1/2| G1/2| G1/2| G1/2| G1/2| G1/2| G1/2
TS2| Thermo pocket level 2| G1/2| G1/2| G1/2| G1/2| G1/2| G1/2| G1/2
EE| Opening for electric element|

G1 1/2

|

G1 1/2

|

G1 1/2

|

G1 1/2

|

G1 1/2

|

G1 1/2

|

G1 1/2

MA1| Magnesium anode 1| –| G3/4| G3/4| G1 1/4| G1 1/4| G1 1/4| G1 1/4
MA2| Magnesium anode 2| G1 1/2| G1 1/2| G1 1/2| G1 1/4| G1 1/4| G1 1/4| G1 1/4
MA3| Magnesium anode 3| –| –| –| –| –| G1 1/4| G1 1/4
DIMENSIONS

±5mm

|  | TESY EV 7/5 S2 200 60 45D| TESY EV 10/7 S2 300 65 45D| TESY EV 15/7 500 75 45D| TESY EV 12/9 S2 800 99 45D| TESY EV 13/7 S2 1000 105 45D| TESY EV 12/8 S2 1500 120 45D| TESY EV 14/9 S2 2000 130 45D
---|---|---|---|---|---|---|---|---
h| mm| Height| 1 202| 1 422| 1 677| 1 947| 2 012| 2 207| 2 412
a| mm| TR| 955| 1 179| 1 408| 1 591| 1 649| 1 770| 1 918
b| mm| EE| 649| 786| 1 023| 1 110| 1 232| 1 170| 1 338
c| mm| Flange| 342| 345| 383| 465| 474| 475| 533
d| mm| HW| 1 090| 1 415| 1 571| 1 779| 1 846| 2 070| 2 246
e| mm| IS2| 912| 1 116| 1 369| 1 567| 1 564| 1 723| 1 903
f| mm| R| 772| 915| 1 167| 1 305| 1 414| 1 400| 1 551
g| mm| OS2| 697| 815| 1 068| 1 180| 1 263| 1 283| 1 408
i| mm| IS1| 587| 700| 933| 1 040| 1 109| 1 075| 1 243
j| mm| OS1| 339| 347| 353| 440| 508| 450| 463
k| mm| CW| 105| 89| 89| 82| 82| 90| 90
m| mm| TS1| 525| 595| 863| 840| 1 017| 930| 878
n| mm| TS2| 797| 960| 1 233| 1 430| 1 469| 1 500| 1 528
R| mm| Diagonal| 1 340| 1 565| 1 838| 2 182| 2 269| 2 512| 2 740

ØC

ØD

|

mm

mm

| Diameter with insulation

Diameter water tank

|

600

500

|

650

550

|

750

650

|

990

790

|

1 050

850

|

1 200

1 000

|

1 300

1 100

TESY in numbers

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-6

Scan this code to watch TESY corporate video

MORE THAN 65 COUNTRIES
TESY is one of the leading European producers of electric storage water heaters, indirectly heated water tanks, electric heating appliances, and heat pump water waters.

4 CONTINENTS
In the last decade, TESY demonstrated rapid development and introduced a wide range of cutting-edge products and patented solutions that meet the current requirements for energy efficiency and environmental protection.
The company continues its growth by investing in the latest technologies, production capacity, and new products.

MORE THAN 1200 EMPLOYЕES
Since October 2017, TESY has been an official member of the EHPA (European Heat Pump Association), which aims to provide technical and financial support to European, national and local authorities on legislative, regulatory and energy efficiency matters.

4 FACTORIES
TESY is also a member of the European Technical Commission which focuses on the development of European regulations regarding energy efficiency, for which we carry out laboratory tests and analyses of electric water heaters in order to verify and validate the methodology described in the European regulations.

Corporate social responsibility

  • TESY is committed to integrating corporate Social responsibility into all business policies and practices and thus minimizing the environmental impact during production.
  • We strive to constantly improve established processes and we are strictly following all regulations for environmental protection.
  • As our focus is on efficiency, our appliances can also use alternative sources of energy.

TESY-EV-7-5-S2-Order-Autonomous-Boiler-With-Delivery-in-Moldova-
fig-8

Tesy Ltd.
Sofia Park, Building 16 V, 2nd Floor 1766 Sofia, Bulgaria

This is a marketing material and it is not an offer.
For specific models, please contact your dealer.

Copyright © All Rights Reserved, v. 1 2023 – TESY Ltd.

Scanner

tesy.com

Frequently Asked Questions

  • Q: How do I adjust the temperature of the hot water?
    • A: Use the thermoregulator to set the desired temperature of the hot water.
  • Q: What should I do if I notice a leak from the unit?
    • A: Turn off the unit immediately and contact a professional for repairs.
  • Q: How often should I clean the heat exchangers?
    • A: It is recommended to clean the heat exchangers at least once a year to ensure optimal performance.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals