TESY AC 37 HCICH Air Cleaner Instruction Manual

June 5, 2024
TESY

TESY AC 37 HCICH Air Cleaner

 **Instruction Manual**

TESY AC 37 HCICH Air Cleaner Instruction Manual

www.tesy.com

IMPORTANT SAFETY INSTRUCTIONS

WARNING!

When using electrical appliances, basic precautions should always be followed to reduce breakage, risk of fire, electric shock and injury to persons including the following:

  • Please read this manual before using this product and save it for future reference. In case that the product is acquired by a new owner he/she must get this manual.
  • Children under 3 years of age should be kept away from the appliance unless they are under constant supervision.

Children from 3 to 8 years of age are allowed to operate the on/off button ONLY, provided that the appliance is installed and ready for operation and such children have been supervised and instructed in safe operation of the appliance and they understand all related risks.

Children from 3 to 8 years of age MUST NOT: connect the plug to power sockets, make adjustments, clean it or carry out user maintenance operations.

  • This appliance can be used by children older than 8 years of age and by people with reduced physical, sensor and mental capabilities, as well as by people with insufficient experience and knowledge provided they are supervised or instructed in safe operation of the appliance and understand the related risks. Children should not be allowed to play with the appliance. Cleaning and user maintenance operations must not be carried out by children without supervision.

  • Read all instructions before operating the air cleaner.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  • Place the air cleaner where it is not possible to be easily knocked over by persons in the household.

  • ALWAYS unplug air cleaner when not in use.

  • DO NOT use any product with a damaged cord or plug, or if product malfunctions, is dropped or damaged in any manner.
    If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid hazard to the user.

  • Keep the power cord away from heated surfaces.

  • Do not use the air cleaner outdoors.

  • Never use the air cleaner unless it is fully assembled.

  • Do not run power cord under carpets and DO NOT COVER with throw rugs. Arrange cord so it will not be tripped over.

  • Do not use air cleaner where combustible gases or vapors are present.

  • Do not expose the air cleaner to rain, or use near water, in a bathroom, laundry area or other damp locations.

  • To disconnect the air cleaner, press the button to turn off and remove plug from outlet.

  • Do not allow foreign objects to enter ventilation or exhaust opening, as this may cause electric shock or damage to the air cleaner.

  • Place the air cleaner near a power outlet, and avoid using an extension cord.

  • A loose fit between the plug and the AC outlet (receptacle) may cause overheating and distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.

  • Do not sit, stand or place heavy objects on the air cleaner.

  • Always disconnect power supply before servicing.

  • In order to reduce risk of fire or electric shock – DO NOT use this product with a revolutions control device.

  • Do not use other accessories that are not approved by the manufacturer. If the machine malfunctions, the warranty will be automatically terminated.

  • Please check if the product has a slow injury after removing the package and check if the accessories are complete.

  • If a malfunction occurs, immediately unplug the power supply and do not put the defective product in working condition.

  • This product can only be repaired in an authorized repair center. It is easy to cause other unsafe factors when repairing in an unauthorized repair center.

  • Do not plug in the power plug when your hands are wet.

  • When you unplug the power cord, you must hold the plug and not pull the power cord. Failure to do so may result in electric shock or fire due to short circuit.

  • When using spray insecticide, do not use this machine, or if there is oil residue in the room, smoke when burning incense, fire when smoking cigarettes, chemical smell in the air, or where the bathroom is very humid, do not use it.

  • When moving the unit, always hold the handles on both sides of the main unit. When moving, if you hold the front panel, the panel may fall off and fall off the main unit, causing personal injury.

  • Regularly remove dust from the power plug

  • Do not operate the unit without a filter installed.

  • Do not clean and reuse composite filters

  • Be careful when cleaning the air purifier. A highly corrosive cleaning agent can damage the surface of the unit.

  • Do not use alcohol or organic solvent to wipe it, otherwise it will damage the product or cause electric shock, fire, etc.

INTRODUCTION

Congratulations on your choice of TESY Air Cleaner.

We highly recommend that you operate the Air Cleaner 24 hours a day, because indoor air can be quickly contaminated by activity or objects in a room and infiltration of outside air. Portable air cleaners are much more effective in rooms where all doors and windows are closed.

The appliance will give you long-lasting service if operated and taken care of correctly in accordance with these instructions.

PRODUCT PARTS

TESY AC 37 HCICH Air Cleaner - PRODUCT PARTS

One full set filters

TESY AC 37 HCICH Air Cleaner - One full set filters

Note : Before use remove the protection polyethylene envelope above the filters.

OPERATION

After power on, machine entry to the standby state, “Power” button light shows red.

TESY AC 37 HCICH Air Cleaner - OPERATION

MAINTENANCE

Note : Please use a damp cloth stained with a little detergent water to clean the machine surface periodically, and to clean the air inlet and outlet with a soft brush.

Body cleaning

  • Wipe the stain out with a soft cloth
  • Regarding some stubborn stain, it is ok to wipe it out with a damp cloth stained with a little detergent water to clean it.

Note : Do not scratch the machine case with hard objects when maintaining

Note : Please follow the instructions when removing the front panel.

TESY AC 37 HCICH Air Cleaner - Regarding some stubborn
stain

Note : The use of different environments, the replacement of the filter cycle vary greatly, please use the filter as non-combustible waste disposal.

FILTER INSTALLATION

Product purification principle

– Pre-filter:

It can filter hair, pet hair and other large particles

– HEPA filter:

The function of the HEPA filter is to absorb particles – dust, pollen, fungi spores and different kinds of bacteria. HEPA filter can not absorb particles smaller than 0.3 micron
– such as chemical evaporations, gases, some tobacco smoke particles, germs and viruses. HEPA filter efficiency is
up to 99.97%.

– Carton Cloth Mesh Filter:

HEPA filter layer, which can effectively remove PM2.5, smoke and other small particles of air pollutants. Activated carbon filter layer, can effectively filter formaldehyde, benzene and other harmful gases, which can effectively remove the odor.

– Filter cold catalyst:

Cold catalyst is used to decomposite the harmful gas into CO2 and H2O, such as benzene and formaldehyde.

– Negative ions generator:

Negative ion generator can purify air pollution, while the release of the beneficial negative oxygen ions

TESY AC 37 HCICH Air Cleaner - Negative ions generator

FILTER REPLACEMENT

  1. When the indicator is flashing, reminding the filter needs to be replaced; At this time, cut off power supply, put hands on the front cover, and then take off the front cover.
    TESY AC 37 HCICH Air Cleaner - When the indicator is
flashing

  2. Replace the primary filter. Hold down the buckle, pull out, remove the filter at the bottom of the main groove, close the filter.
    TESY AC 37 HCICH Air Cleaner - Replace the primary
filter

  3. Replace the filter. Pull out the filter by the tip, then you can replace the carbon cloth mesh filter.

TESY AC 37 HCICH Air Cleaner - Replace the filter. Pull out the filter by
the tip
Note: After filter replacement, press FILTER button 3s for reset

Injecting water

  1. When water is shortage, the icon is light up to remind injecting water.

  2. Pull put water tank, take out the wet cotton, inject water.

  3. Open cover, clean the water tank.

TECHNICAL PARAMETERS

TESY AC 37 HCICH Air Cleaner - TECHNICAL PARAMETERSTESY AC 37 HCICH Air Cleaner - TECHNICAL PARAMETERS
2

Environment protection instructions.

Old electrical appliances contain valuable materials and therefore should not be treated as domestic waste! We kindly ask you to cooperate us with your active contribution to resources and environment preservation by disposing the appliance to authorized waste-disposal locations (if there are any).

CAUTION

NOTES

TESY AC 37 HCICH Air Cleaner - NOTES

TESY Ltd – Head office
1166 Sofia, Sofia Park,
Building 16V, Office 2.1. 2nd Floor
PHONE: +359 2 902 6666,
FAX: +359 2 902 6660,
office@tesy.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals