IMPORTANT SAFETY INSTRUCTIONS
WARNING!
When using electrical appliances, basic precautions should always be followed to reduce breakage, risk of fire, electric shock and injury to persons including the following:

  • Please read this manual before using this product and save it for future reference. In case that the product is acquired by a new owner he/she must get this manual.

  • Children under 3 years of age should be kept away from the appliance unless they are under constant supervision.
    Children from 3 to 8 years of age are allowed to operate the on/off button ONLY, provided that the appliance is installed and ready for operation and such children have been supervised and instructed in safe operation of the appliance and they understand all related risks.
    Children from 3 to 8 years of age MUST NOT: connect the plug to power sockets, make adjustments, clean it or carry out user maintenance operations.

  • This appliance can be used by children older than 8 years of age and by people with reduced physical, sensor and mental capabilities, as well as by people with insufficient experience and knowledge provided they are supervised or instructed in safe operation of the appliance and understand the related risks. Children should not be allowed to play with the appliance. Cleaning and user maintenance operations must not be carried out by children without supervision.

  • Read all instructions before operating the air cleaner.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  • Place the air cleaner where it is not possible to be easily knocked over by persons in the household.

  • ALWAYS unplug air cleaner when not in use.

  • DO NOT use any product with a damaged cord or plug, or if product malfunctions, is dropped or damaged in any manner. If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid hazard to the user.

  • Keep the power cord away from heated surfaces.

  • Do not use the air cleaner outdoors.

  • Never use the air cleaner unless it is fully assembled.

  • Do not run power cord under carpets and DO NOT COVER with throw rugs. Arrange cord so it will not be tripped over.

  • Do not use air cleaner where combustible gases or vapors are present.

  • Do not expose the air cleaner to rain, or use near water, in a bathroom, laundry area or other damp locations.

  • To disconnect the air cleaner, press the button to turn off and remove plug from outlet.

  • Do not allow foreign objects to enter ventilation or exhaust opening, as this may cause electric shock or damage to the air cleaner.

  • Place the air cleaner near a power outlet, and avoid using an extension cord.

  • A loose fit between the plug and the AC outlet (receptacle) may cause overheating and distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.

  • Do not sit, stand or place heavy objects on the air cleaner.

  • Always disconnect power supply before servicing.

  • In order to reduce risk of fire or electric shock ­ DO NOT use this product with a revolutions control device.

  • Do not use other accessories that are not approved by the manufacturer. If the machine malfunctions, the warranty will be automatically terminated.

  • Please check if the product has a slow injury after removing the package and check if the accessories are complete.

  • If a malfunction occurs, immediately unplug the power supply and do not put the defective product in working condition.

  • This product can only be repaired in an authorized repair center. It is easy to cause other unsafe factors when repairing in an unauthorized repair center.

  • Do not plug in the power plug when your hands are wet.

  • When you unplug the power cord, you must hold the plug and not pull the power cord. Failure to do so may result in electric shock or fire due to short circuit.

  • When using spray insecticide, do not use this machine, or if there is oil residue in the room, smoke when burning incense, fire when smoking cigarettes, chemical smell in the air, or where the bathroom is very humid, do not use it.

  • When moving the unit, always hold the handles on both sides of the main unit. When moving, if you hold the front panel, the panel may fall off and fall off the main unit, causing personal injury.

  • Regularly remove dust from the power plug

  • Do not operate the unit without a filter installed.

  • Do not clean and reuse composite filters

  • Be careful when cleaning the air purifier. A highly corrosive cleaning agent can damage the surface of the unit.

  • Do not use alcohol or organic solvent to wipe it, otherwise it will damage the product or cause electric shock, fire, etc.

INTRODUCTION

Congratulations on your choice of TESY Air Cleaner.

Purification principle

We highly recommend that you operate the Air Cleaner 24 hours a day, because indoor air can be quickly contaminated by activity or objects in a room and infiltration of outside air. Portable air cleaners are much more effective in rooms where all doors and windows are closed.

The appliance will give you long-lasting service if operated and taken care of correctly in accordance with these instructions.

PRODUCT PARTS

One full set filters

Note: Before use remove the protection polyethylene envelope above the filters.

Purification principle

OPERATION

Feature Introduction
Turn on the power. You will hear a sound, the display buttons turn green for 1 second. and then turn off. The appliance enters standby mode. The power button lights up in red and the others do not light up.

TESY AC 96 HCIUV AIR CLEANER User Guide - Feature
Introduction TESY AC 96 HCIUV
AIR CLEANER User Guide - Feature Introduction

Indication Particulate Matter (PM2.5)

Duping and opening safety protection:

  1. The device will stop working automatically for safety protection when open the right & left door or slop over 30 degree.
  2. The device will re-work normal when close the right & left door or turn back to horizontal position.

FILTER REPLACEMENT

When the filter life is out, the “ON/OFF” button will shining and with “di di di” sound to reminder users to replace the new filter.

  1. When filter life is out of time, press “SPEED”+ “AUTO” button 3s to reset the filter life, the “ON/OFF” button will stop shining and sound after reset the filter life.
  2. When filter life is not out of time, press “SPEED”+ “AUTO” button 10s to force to reset the filter life.
  3. The device filter life is setting as 3000 hours, record by each hour.
  • Shut down and power off the main unit.

Note: Turn on the air to turn off the air purifier. The air purifier is in standby mode. You need to unplug the power plug to cut off the power of the main unit.

  • Open the lid cover, catch the button of the lid cover, and pull it out.

  • Remove the filter in turn and wrap the waste filter with a garbage bag to prevent the pollutants on the filter from falling into the room.

Note:
a. Dispose of the used filter as non-burnable waste.
b. The primary filter can be used repeatedly. Please clean it and dry it.

  • Grab the door cover buckle, align the bottom of the door cover with the groove at the bottom of the main unit, then close the door cover and plug in to run.

  • Please reset the filter reminder after the filter is replaced.

Note:

  1. Please read the filter replacement operation in detail to ensure the purification effect of the air purifier.
  2. Before cleaning the air purifier system, unplug the power cord and cut off the power to the air purifier system.
  3. Keep the inside of the air purifier dry to prevent damage to the circuit.

****Note: The filter time and usage time are measured in one hour, and the time less than one hour will not be recorded. When the machine is dumped, the whole machine stops working to ensure user safety.

CLEANING AND MAINTENANCE

Feature Introduction
The power plug must be unplugged before servicing the machine.

  1. Clean the body
    – Use a soft cloth to remove the stain.
    – Stubborn stains that cannot be easily erased can be wiped with a moderate amount of neutral detergent on a soft
    ** Note:** Do not scratch the machine casing with hard objects during maintenance. When removing the front cover, please follow the instructions and do not damage the machine parts.

  2. Cleaning and replacement of the filter
    – The filter replacement is reminded by the built-in program. However, due to the different degree of pollution in the actual application environment, the use cycle of the filter will be different, and it can be replaced in time according to the size and smell of the sound generated by the machine.

Recommendation: Clean every 1 month. If the environment is poor, remind the high cleaning frequency.
– When the surface of the composite filter is dusty, use a vacuum cleaner to clean the surface dust to extend the filter.

Recommendation: It is recommended to clean every 1 month

  • Depending on the place of use and the method of use (for example, households with a large number of smokers), the cycle of filter replacement may be shortened. If the effect is not good, please replace it in time.
  • Please use the used filter as non-burnable waste.

TECHNICAL PARAMETERS

TESY AC 96 HCIUV AIR CLEANER User Guide - TECHNICAL
PARAMETERS

Environment protection instructions.
Old electrical appliances contain valuable materials and therefore should not be treated as domestic waste! We kindly ask you to cooperate us with your active contribution to resources and environment preservation by disposing the appliance to authorized waste-disposal locations (if there are any).

COMMON PROBLEMS

If you can’t solve the problem after the above inspection, please contact the service network or technical service center provided by our customer service center. Do not disassemble and repair it yourself to avoid danger and damage to the machine.

TESY AC 96 HCIUV AIR CLEANER User Guide - COMMON
PROBLEMS

TESY Ltd – Head office 1166 Sofia, Sofia Park, Building 16V, Office 2.1. 2nd Floor PHONE: +359 2 902 6666, FAX: +359 2 902 6660,