HUDSON VALLEY H836101L-AOB Elowen 7 Tall Wall Sconce Owner’s Manual

April 2, 2024
HUDSON VALLEY

HUDSON VALLEY H836101L-AOB Elowen 7 Tall Wall Sconce

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

FIXTURE INSTALLATION

  1. Disconnect the DRIVER (G)quick connect, and attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bar copper wire) or the GROUND SCREW (C) on the MOUNTINGPLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIREĞ FAILURE TO FOLLOW THIS COULDRESULT IN SERIOUS IN URY OR DEATHĞ
  2. Connect the DRIVER (G) neutral fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (D). Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUSSHORT CIRCUITĞ
  3. Connect the DRIVER (G) hot fixture leads to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TOFOLLOW THIS COULD RESULT IN SERIOUS IN URY OR DEATHĞ. Push the wires and DRIVER (G) into the junction box.
  4. Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on 2×3 junction box. The junction box must be securely mounted to the structure of the building.
  5. Attach the FIXTURE ASSEMBLY (F) (WITH LED) to the MOUNTING PLATE (A) and secure with the FIXTURE MOUNTING SCREWS (E).
  6. Restore power to the outlet at the breaker or fuse box.
PART(S) REPLACEMENT PART NAME NUMBER
A,B,C,D HARDWARE KIT HDW-H836101S
E FIXTURE MOUNTING SCREW SCR-M
G DRIVER DVR-H836101S