ERMENRICH RD40 Ping Radiation Detector User Manual

June 5, 2024
ERMENRICH

ERMENRICH-LOGO

ERMENRICH RD40 Ping Radiation Detector

Ermenrich Ping RD40 Radiation Detector
Specifications:

  • Dose measurement range
  • Cumulative dose range
  • Exposure dose rate (EDR) measurement range
  • Sensor Measurement accuracy
  • Measurement time
  • Audible alarm
  • Visual alarm
  • Timer
  • Display
  • History records
  • Water-/dustproof certification
  • Charging time
  • Operating temperature range
  • Power supply
  • Battery life
  • Dimensions
  • Weight

Product Usage Instructions

Charging the Device:

  •  This device uses a built-in rechargeable lithium battery. Connect the USB cable to the device and the DC adapter via a USB plug and connect it to the AC power supply to charge the device.
  • Note: The battery needs to be recharged once every 12 months.

Getting Started:

  • Press and hold the Power/Confirm button for 3 seconds to turn the device on/off. The device enters Radiation measurement mode by default. To switch to the main menu, press the Power/Confirm button.
  • Note: When the device is locked, select Schedule (Timed measurement) and click Stop timer to turn the timer off.

Usage:

  • History Records: A history record is automatically saved at the end of each measurement. View history records under Records (History records).
  • Data Deletion: Delete current and history data under Delete (Data deletion) menu.
  • Alarm Value Setting, Unit Setting, Sound Setting, Time Setting, Hibernation Setting: Adjust settings as needed.

Frequently Asked Questions (FAQ):

  • Q: How often should I recharge the battery?
    A: The battery needs to be recharged once every 12 months.

  • Q: How do I view history records?
    A: Select Records (History records) from the menu to view the history records.

  • Q: Can I delete specific data?
    A: Yes, you can delete current data or history data by selecting the appropriate option under Data deletion menu.

Ermenrich Ping RD40 Radiation Detector

  • Levenhuk Inc. (USA): 928 E 124th Ave. Ste D, Tampa, FL 33612, USA, +1-813-468-3001, [email protected]
    Levenhuk Optics s.r.o. (Europe): V Chotejně 700/7, 102 00 Prague 102, Czech Republic, +420 737-004-919, [email protected] Levenhuk®, Ermenrich® are registered trademarks of Levenhuk, Inc. © 2006–2024 Levenhuk, Inc. All rights reserved.

  • www.levenhuk.com

  • 20240522

LED indicator

EN Ermenrich Ping RD40 Radiation Detector

  • Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as specified in the user manual.
  • The kit includes: radiation detector, Type-C USB cable, user manual, and warranty.

Charging the device

  • This device uses a built-in rechargeable lithium battery. Connect the USB cable (included) to the device and the DC adapter (not included) via a USB plug and connect it to the AC power supply to charge the device.
  • The battery needs to be recharged once every 12 months.

Getting started

  • Press (5) and hold it for 3s in order to turn the device on/off. The device enters Radiation measurement mode by default. To switch to the main menu, press (5).
  • When the device is locked, it is not possible to turn the device off. Select Schedule (Timed measurement) and click Stop timer (Stop the timer) to turn the timer off.

Usage

Radiation measurement
Select Measure (Radiation measurement) in the main menu to check the real- time, average/cumulative dose rates, and total measurement time.

Timed measurement

  • Select Schedule (Timed measurement) to set the delay time. You can set the delay value between 00 and 99h and a timer value between 00 and 999h. Click Start timer (Start the timer). The device starts counting down. After the Start delay countdown is completed, the real-time dose rate, average dose rate, total measurement time, and cumulative dose rate are reset at the same time. The device starts to Measure the real-time dose and cumulative dose rate. After the countdown is finished and the measurement is completed, the device automatically saves the measured data in the history record.
  • The Start delay (Start the delay time) setting is the countdown to starting the measurement. It can be set in hours, minutes, and seconds. Press Start timer (Start the timer) to enter countdown mode. The measurement starts after the countdown is finished.

History records

  • A history record is automatically saved at the end of each measurement. When 10 history Records have been saved, the newly saved history record will overwrite the oldest one.
  • Select Records (History records) to view the history records.

Data deletion

  • To delete the current data and history data, select Delete (Data deletion) menu. Select Delete Current Data (Current data deletion) to delete the average dose rate and total measurement time. Select Delete History Data (History data deletion) to delete the history records.

Alarm value setting

  • Select Alarm (Alarm setting) to set the dose rate and total dose high alarm values using (4) or (6). The device will emit an audible and visible alarm signal when the radiation concentration exceeds the set alarm values.
  • Real-time dose rate limit value setting range: 0.1-999µSv.
  • Total dose rate limit value setting range: 1-9999µSv.

Unit setting

  • Select Unit (Unit of measurement setting) in the main menu. Press (4) or (6) to switch between µSv and µGy.

Sound setting

  • Select Sound (Audio setting) to set the alarm volume (0 to 9 levels), the number of alarms (0 to 10 times), and the particles sound (on/off). If the particles sound is on, the device will emit sound when the sensor detects ion particles.

Time setting

  • Select Clock (Time setting) to set the date and current time.
  • Date setting: Year > Month > Day
  • Time setting: Hours > Minutes > Seconds
  • Hibernation setting
    • Select Sleep (Hibernation setting) to set the screen off time (in minutes), auto power-off time (in hours), and screen brightness level.

Specifications

Dose measurement range 0.08µSv… 50mSv
Cumulative dose range 0.1µSv… 9999mSv
Exposure dose rate (EDR) measurement range 0.08µSv/h… 50mSv/h
Sensor Geiger–Müller counter tube
Measurement accuracy –17%…+25% based on 137Cs γ
Measurement time < 10s
Audible alarm +
Visual alarm +
Timer +
Display 2.0″ LCD color screen
History records 10 sets
Water-/dustproof certification IP3X
Charging time 3–4 hours
Operating temperature range –20… +50°C / –4… +122°F (operating/storage)
Power supply rechargeable Li-ion battery, 3.7V, 750mA·h; 5V, 2A adapter for

charging (not included)
Battery life| two weeks (provided that the particles sound is off)
Dimensions| 88x43x19 mm
Weight| 50g

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance

  • The device is designed to measure X-, β- and γ-radiation. The values for X-radiation are reference values. Do not expose the device
    to strong radiation. Do not use the device in explosive atmospheres. Do not use the device in humid and dust environments. Store
    the device in a dry cool place. Do not expose the device to shock, continuous vibrations, or extreme high or low temperatures. Do not try to disassemble the device on your own for any reason. For calibration, repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately.

Battery safety instructions

  • The device is equipped with a built-in rechargeable lithium-ion battery. This avoids frequent battery replacement. Always switch the device off when not in use. If the battery charge is low, please recharge the device in time to ensure that the measurements are accurate. Do not overheat the battery. Do not discharge the battery completely. Only use the original charger.

Levenhuk International Warranty

  • Levenhuk products, except for their accessories, carry a 5-year warranty against defects in materials and workmanship. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a
  • Levenhuk office is located if all the warranty conditions are met.
  • For further details, please visit: levenhuk.com/warranty
  • If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals