ACT 5e Digital Keypad Installation Guide

July 2, 2024
ACT

ACT 5e Digital Keypad

INSTALLATION NOTES

Always remember to factory default the controller before you start programming. Always remember to place the supplied varistor across the terminals of the door strike coil to protect the relay contacts. Never use the onboard relay to switch AC mains voltage. An external relay isolated electrically from the ACT 5e should be used for this purpose. Don’t forget to change the programming code to something known only to yourself.

IMPORTANT
As with any access control system, always ensure that there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire.ACT-5e-Digital-Keypad-FIG-1

Mounting Instructions for Surface or Flush ACT 5e

  • Spacers break away from the main component when required by the installer for use
  • View shows mounting plate before spacers are broken away by installer

Note: Determine the distance between the patress box and the mounting plate, using the spacers that are labelled 1mm to 4mm. A spacer of the correct length is assembled by stacking the spacers together.

Surface Mount Unit

ACT-5e-Digital-Keypad-FIG-3

  • The surface mount collar is mounted on the wall using the fixing kit supplied in the box.
  • Place the reader / keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the surface mount collar.

Flush Mount Unit

ACT-5e-Digital-Keypad-FIG-4

  • The mounting plate is attached to the mattress using the screws supplied. Ensure the correct spacers have been used to bridge the gap between the mounting plate and the fixing wings of the pattress box to avoid the mounting plate being distorted.
  • Place the reader/keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the flush mount collar.

ACT 5e Digital Keypad Programming

To enter programming mode:
Press the button followed by the engineering code (initially 9999). The LED will flash amber while in programming mode. If is pressed at any time or no key is pressed within 30 seconds, programming mode is exited.

Changing Codes: from programming mode)

ACT-5e-Digital-Keypad-FIG-6

Toggle Relay (from programming mode):

ACT-5e-Digital-Keypad-FIG-7

Setting the Relay active time (from programmin a mode):

ACT-5e-Digital-Keypad-FIG-8

Settina the Backliaht: (from proarammina mode)

ACT-5e-Digital-Keypad-FIG-10

Restoring Factory Defaults: (from Programming Mode)
(Factory Defaults Restored & Keypad exits programming mode) If the programming code has been forgotten.

  1. Remove the power from the unit.
  2. Remove link LK1.
  3. Apply power to unit.
  4. Wait 3 seconds and remove power again.
  5. Replace link LK1.
  6. Restore power and proceed with programming.

Note: The keypad will not operate correctly without LK1 in place.

30 SECOND PROGRAMMING GUIDE

(for typical system)

  1. Enter Programming Mode. Press X button followed by the programming code (9999) The LED will flash Amber
  2. Change User 1 code. Press , then 1 followed by the new user 1 code (four digits)
  3. Change Programming Code. Press 0, then followed by the new programming code (four digits).
  4. Exit Programming Mode. Press the button. The LED will be Red. The keypad is now ready for normal use.

Note: The keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the key three times.

Incorrect Code Lockout
When three invalid codes have been entered in a row. The keypad will enter lockout mode for 20 seconds. During this time, the red indicator will flash and all user codes will be inactive.