kogan KAVWAC2KYA VERTICAL WINDOW AIR CONDITIONER User Guide

June 5, 2024
Kogan

User Guide

VERTICAL WINDOW AIR CONDITIONER
(1.75KW, COOLING ONLY)
KAVWAC2KYA

SAFETY & WARNINGS

Warnings

  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority. This authorizes their competence to handle refrigerants’ safety by an industry-recognized assessment specification.

  •  Dispose of the appliance packaging responsibly.

  • The appliance shall be stored in a well-ventilated area. The size of the area corresponds to the room area specified for operating the appliance.

  • Store the appliance safely to prevent any mechanical damage.

  • Ensure the following regarding the refrigerant pipes:
    o The installation of pipework shall be kept to a minimum.
    o The pipework shall be protected from physical damage and, in the case of flammable refrigerants, shall not be installed in an unventilated space.
    o Compliance with national gas regulations shall be observed.
    o The mechanical connections shall be accessible for maintenance purposes.
    o For appliances containing flammable refrigerants, the minimum floor area of the room shall be mentioned in the form of a table or a single figure without reference to a formula.

  • Keep any required ventilation openings clear of obstruction.

  • Ensure ducts connected to the appliance do not contain a potential ignition source.

  • When the portable air conditioner or dehumidifier is turned on, the fan can work continuously under normal conditions to provide the minimum air volume of 100m3/h even when the compressor is closed due to the temperature controller.

  • Do not pierce or burn the appliance.

  • Use only implements recommended by the manufacturer for defrosting or cleaning.

  • Do not perforate any of the components in the refrigerant circuit. Refrigerant gas may be odorless.

  • Maintenance and repairs requiring the assistance of other qualified personnel must be carried out under the supervision of specialists in the use of inflammable refrigerants.

Appliance with R290 Refrigerant Gas

Note: Refer to the rating plate on your appliance to know the type of refrigerant gas used.


Caution:
Risk of fire

  • DANGER: It is hazardous for anyone other than an authorized service person to service this appliance. In Queensland, the authorized service person MUST hold a Gas Work Authorisation for hydrocarbon refrigerants to carry out servicing or repairs that involve the removal of covers.
  • This appliance contains approximately 150 grams of R290 refrigerant gas.
  • The appliance shall be installed, operated, and stored in a room with a floor area larger than 4 meters square.

Precautions

  • This appliance is not intended for use by persons (including children) with weak
    physical, sensory, or mental abilities or lack of experience and knowledge unless
    their use is supervised or instructed by personnel responsible for their safety.

  • Supervise children to ensure they do not play with this appliance.

  • Install the appliance correctly to ensure it is at a minimum allowable distance from
    the adjacent structures. See the Installation section of this user guide.

  • Follow the correct wiring connection type when operating or repairing.

  • Do not use the appliance in an explosion-hazardous room.

  • Do not use the appliance in a corrosive environment.

  • Keep the appliance upright and stable.

  • Allow the appliance to dry after wet cleaning. Do not operate when wet.

  • Do not use the appliance with wet hands.

  • Do not spray water directly on the appliance.

  • Never insert any objects or limbs into the appliance.

  • Do not cover or transport the appliance during operation.

  • Do not sit on the appliance.

  • Do not leave the device unattended during operation.

  • Electrical connections must meet technical requirements.

  • Insert the power plug into a properly secured power outlet.

  • When selecting an extension cord for a power cord, pay attention to the power input of the device, the cable length, and the intended use. Fully extend the expansion cable. Avoid electrical overload

  • Before repairing the appliance, unplug the power plug from the electrical outlet.
    Hold the power plug when doing this; do not pull on the cord.

  • When not using the appliance, turn off the device and unplug the power cord from the power outlet.

  • If you notice damage to the power plug or power cord, cease the use of the appliance and contact Kogan.com

  • When placing the appliance, pay attention to the minimum distance from walls and other objects. For storage and operating conditions, see the Cleaning and Care section of this user guide.

  • Ensure that air inlets and outlets are not blocked.

  •  Make sure the suction side is free of dust and lose objects

  • Do not remove any safety signs, stickers, or labels from the device.

  • Drain the collected condensate water before transportation and storage. Do not drink it as it is harmful to health.

OVERVIEW

Air Conditioner

| 1 Front Panel
2 Vertical Blade (Auto Swing)
3 Level Blade (Manually Swing)
4 Filter
5 Display Panel
6 Power Line
7 Indoor Water Hole
8 Back Panel
9 Outdoor Air Inlet
10 Outdoor Water Hole
11 Outdoor Air Outlet
12 Standard Frame
13 Chassis
---|---

Air Conditioner Window Frame

INSTALLATION

Before Installation

  • To avoid damage, place the unit in an upright position for at least 24 hours before installation.
  • Make sure that the air outlet and air inlet are never blocked.
  • Operate the unit on a horizontal surface to avoid water leakage.

Air Conditioner Window Frame Installation Requirements

  • The height of the window should be higher than 85cm.

  • The window should have a groove.

  • If there is no groove (e.g. wood window) contact professional people to install it.

  • The window height should be shorter than the max height of the frame to avoid the appliance from falling.

  • The following instruments are required:o Tape
    o Cross screwdriver
    o Scissor

  • Power supply details:o Connect to a power supply directly and do not use an extension cord.
    o, Ensure the plug is connected.

  • Sketch the map of the frame for installation:

Installation Steps
Step 1: Choose the installation location.

Note: To install the air conditioner, wait for two hours after delivery to keep the refrigerant gas stable.

Step 2: Install the air conditioner window frame.

Note: Cover the window completely with the Standard Frame.

  1. Open the window from left or right.

  2. Ensure the bottom of the Inside Frame is inserted at the first groove (as shown in the image I).

  3. Stretch the Inside Frame and ensure it is aligned to the groove of the window (II).

  4. Slide the Inside Frame to the side of the window (III).

  5. Use two screws to lock the Inside Frame. Position the protector between the top and bottom and tighten the screws (IV).
    Note: Ensure the air conditioner frame installation is stable.

  6. Use a suitable sponge to seal the remaining gaps (V).

Step 3: Install the air conditioner.

  1. Unscrew the standard frame.

  2. There are two holes with a locker on the backside of the air conditioner, push one time to lock.

  3. The grey bulge part is a Standard Frame. The Standard Frame bottom should be locked completely between the sponge and the inside groove.

  4. Tighten the Unit Fixed Screw to lock the air conditioner

Note: Ensure the air conditioner is installed securely.

Step 4: Disassemble the air conditioner

  1. Follow the air condition installation steps in reverse order to disassemble the air conditioner.
  2. Push the Unit Locker to left and hold the air conditioner to avoid dropping.

Note: Be careful when disassembling the air conditioner. Do not drop the air conditioner.

OPERATION

Operation Panel and Remote Control

1 AUTO Press this button to operate air conditioner in the automatic mode.
2 POWER Press this button to turn on the air conditioner.
3 CHILD LOCK Press this button to lock the operation panel.
4 TIMER Press this button to turn off or turn on the timer.
5 FAN Press this button to change the fan speed (high, middle, or low).
6 UP/DOWN Press to increase or decrease the temperature and timer settings.
7 SWING Press this button to turn on or off the swing function.
8 SLEEP Press this button to put the air conditioner to sleep mode.
9 MODE Press this button to switch between auto, cooling, fan, and dry

modes.

Time setting

  1. Standby State
    1. Press the TIMER button to start the timer. The timing range is 0-24 hours.
    2. Press the UP and DOWN keys to set the time. Before 6 hours, every up or down adjustment is 0.5 hours, after 6 hours, every up or down adjustment is 1 hour, and
    the corresponding timer status indicator lights up.

  2. Power-on State
    1. Press the TIMER button to set the timer shutdown.
    2. Press the UP and DOWN keys to set the time. Before 6 hours, every up or down adjustment is 0.5 hours, after 6 hours, every up or down adjustment is 1 hour, and the corresponding timer status indicator lights up.

Working Mode Operation

  • Cooling mode:
    1. Press the MODE button to select the cooling mode during the power-on state. At this point, the corresponding indicator lights up.
    2. Press the UP and DOWN keys to set the appropriate temperature. The setting range is 16~30°C. Each time you press the up or down button, the temperature will rise or fall by 1°C.
    3. Press the FAN button to select the appropriate fan speed and you can cycle through the low, mid, and high wind.
    4. Press the SWING button to turn the swing function on or off.

  • Dehumidify mode:
    1. Press the MODE button to select the dehumidification mode during the power-on state. The corresponding indicator lights up.
    2. Wind speed is not adjustable.
    3. Press the SWING button to turn the swing function on or off

  • Fan mode:
    1. Press the MODE button to select the fan mode during the power-on stage. The corresponding indicator lights up.
    2. Press the FAN button to select the appropriate fan speed and you can cycle through the low wind, mid and high speed.
    3. The temperature is not adjustable.
    4. Press the SWING button to turn the swing function on or off.

  • Automatic mode:
    1. Press the MODE key in the power-on state or press the AUTO button to select the automatic mode. The corresponding indicator lights up.
    2. The automatic mode operates in the cooling mode. The default setting temperature is 24°C. The setting range is 16~30C and the temperature can be adjusted within this range.
    3. The fan speed will adjust automatically to the set temperature and the ambient temperature and the speed is not adjustable.
    4. The automatic mode swing function is enabled by default and the swing function can be turned off or on by the SWING button.

  • Sleep mode:
    1. Press the SLEEP button to select the sleep mode in the power-on state. The corresponding indicator lights up. In this mode, it operates according to the cooling
    function.
    2. The default setting temperature is 26°C. The setting range is 16~30C and the temperature can be adjusted within this range.
    3. The fan speed is set to low and is not adjustable.
    4. Press the swing key to turn off and turn on the swing function.
    5. After entering sleep mode, the indicator light turns dark, and the set temperature increases by 2°C for two hours. After 8 hours of sleep mode, the air conditioner shuts down.

  • Child lock function:
    1. Press the CHILD LOCK button for 3 seconds to lock the operation panel. Press this button again for 3 seconds to unlock.
    Note: When the water level indicator shows water is full, the machine will stop working and you should drain the water. After draining, the machine can be restarted. See the Cleaning and Care section of this user guide.

REPAIR

Repairing Appliances Containing R290

  1. Checks to the area
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precaution shall be completed prior to conducting work on the system.

  2. Work procedure
    Work shall be undertaken under a controlled procedure to minimize the risk of flammable gas or vapor being present while the work is being performed.

  3. General work area
    All maintenance staff and others working in the local area shall be instructed on the nature of the work being carried out. Work in confined spaces shall be avoided.

  4. Checking for the presence of refrigerant
    The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.

  5. Presence of fire extinguisher
    If any hot work is to be conducted on the refrigerating equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  6. No ignition sources
    No person carrying out work in relation to a refrigerating system that involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removal, and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

  7. Ventilated area
    Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  8. Checks to the refrigerating equipment
    Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times, the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
    The following checks shall be applied to installations using flammable refrigerants:

• The actual refrigerant charge is in accordance with the room size within which the refrigerant-containing parts are installed.
• The ventilation machinery and outlets are operating adequately and are not obstructed.
• If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
• Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected.
• Refrigerating pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.

  1. Checks to electrical devices
    Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise the safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used.
    This shall be reported to the owner of the equipment, so all parties are advised.
    Initial safety checks shall include:
    • That capacitor is discharged: this shall be done safely to avoid the possibility of sparking,
    • That no live electrical components and wiring are exposed while charging, recovering, or purging the system,
    • That there is continuity of earth bonding.

  2. Repairs to sealed components
    During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon before any removal of sealed covers, etc. If it is necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
    Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, an excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
    Ensure that the apparatus is mounted securely.
    Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres.
    Replacement parts shall be by the manufacturer’s specifications.

  3. Repair to intrinsically safe components
    Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and currently permitted
    for the equipment in use.
    Intrinsically safe components are the only types that can be worked on while living in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
    Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

  4. Cabling
    Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverse environmental effects. The check shall also consider the effects of aging or continual vibration from sources such as compressors or fans.

  5. Detection of flammable refrigerants
    Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  6.  Removal and evacuation
    When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, for flammable refrigerants, best practices must be followed since flammability is a consideration.
    The following procedure shall be adhered to:
    • Remove refrigerant
    • Purge the circuit with inert gas
    • Evacuate
    • Purge with inert gas
    • Open the circuit by cutting or brazing.
    The refrigerant charge shall be recovered into the correct recovery cylinders. For appliances containing flammable refrigerants, the system shall be purged with oxygen-free nitrogen to render the appliance safe for flammable refrigerants. This process may need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems.
    For appliances containing flammable refrigerants, refrigerants purging shall be achieved by breaking the vacuum in the system with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then venting to the atmosphere and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final oxygen-free nitrogen charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is vital if brazing operations on the pipework are to take place.
    Ensure that the outlet for the vacuum pump is not close to any potential ignition sources and that ventilation is available.

  7. Charging procedures
    In addition to conventional charging procedures, the following requirements shall be followed.
    • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
    • Cylinders shall be kept in an appropriate position according to the instructions.
    • Ensure that the refrigerating system is earthed before charging the system with refrigerant.
    • Label the system when charging is complete (if not already).
    • Extreme care shall be taken not to overfill the refrigerating system.
    Before recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but before commissioning. A follow-up leak test shall be carried out before leaving the site.

  8. Decommissioning
    Before carrying out this procedure, the technician must be completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Before the task is carried out, an oil and refrigerant sample shall be taken in case analysis is required before re- use of recovered refrigerant. Electrical power must be available before the task is commenced.
    a) Become familiar with the equipment and its operation.
    b) Isolate the system electrically.
    c) Before attempting the procedure, ensure that:
    • Mechanical handling equipment is available, if required, for handling refrigerant cylinders.
    • All personal protective equipment is available and being used correctly.
    • The recovery process is always supervised by a competent person.
    • Recovery equipment and cylinders conform to the appropriate standards.
    d) Pump down the refrigerant system, if possible.
    e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
    f) Make sure that the cylinder is situated on the scales before recovery takes place.
    g) Start the recovery machine and operate by instructions.
    h) Do not overfill cylinders (no more than 80% volume liquid charge).
    i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
    j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off.
    k) Recovered refrigerant shall not be charged into another refrigerating system unless it has been cleaned and checked.

  9. Labeling
    Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. For appliances containing flammable refrigerants, ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

  10.  Recovery
    When removing refrigerants from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
    When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with a pressure-relief valve and associated shut- off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
    The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants. Also, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained, and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
    Consult the manufacturer if in doubt.
    The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
    If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out before returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When the oil is drained from a system, it shall be carried out safely.

CLEANING & CARE

Note: Turn off the air conditioner and remove the plug connected to a power supply before cleaning.

Cleaning the surface

  1. Wash the surface with a soft, damp cloth.
  2. Do not use chemical reagents such as benzene, alcohol, or gasoline. Otherwise, the surface of the air conditioner will be damaged or even the whole machine.

Cleaning the filter:
If the filter is clogged with dust it will affect the air conditioner’s performance. Clean the filter every two weeks.

  1. Remove the standard screws fixed on the grille and the front panel.
  2. Pull down the grille to remove it. Then remove the filter from the front panel.
  3. Put the filter into warm water (about 40°C or 104°F) which has neutral detergent, rinse it, and dry it in a cool place.

Draining Water
When the water level indicator shows water is full, the air conditioner will stop working. It is necessary to remove excess condensate water. You can select either the indoor condensate drain or the outdoor condensate drain when draining the condensate water.
Note: Draining water through the indoor drain hole requires a barrel or a bucket that can hold water to prevent the water from flowing to the floor directly.

Storing the Air Conditioner

  1. Remove the indoor plug, drain the water to other water containers or directly remove the outdoor condensate plug to drain the water out of the room.
  2. Adjust the fan mode to the low air condition. Keep this state for a long time until the catheter dries. This operation will dry the inside of the body and prevent mold.
  3. Turn off the machine and unplug the power cord. Wrap the power cord and install a water plug.
  4. Remove the machine from the window, remove the mounting bracket and keep it in a good condition.
  5. Put the air conditioner in a plastic bag and put it in a dry place to prevent dust. Do not let the children touch it.
  6. Take out the battery of the remote controller.

TROUBLESHOOTING

Note: Do not repair or disassemble the air conditioner yourself. Repairs done by unqualified persons will void the warranty and may cause damage to the air conditioner.

Problem Cause Solution
Air Conditioner is not working No power. Turn on the power after receiving

the power socket.
The water level indicator displays FL.| Drain water.
Temperature is too low or too high.| Recommend using the machine between 7-35°C.
The room temperature is lower than the set temperature in cooling mode.| Changeset temperature.
Low ambient temperature in dehumidification mode.| Place in a room with an ambient temperature greater than 17°C.
Insufficient cooling| There is direct sunlight.| Draw the curtains.
The doors and windows are open.

The frame is not sealed or there are some other heat sources.

| Close the door or window. Seal the frame.
The filter is dirty.| Clean or replace the filter.
The air inlet or outlet is blocked.| Clear obstacles.
The air conditioner makes a loud noise| The air conditioner is not installed correctly.| Check the frame and air conditioner to ensure proper and correct installation.
The compressor is not working| Overheat protection is on.| Wait for 3 minutes until the temperature drops and then turn it on.
The air conditioner remote does not work| The remote is used from a long distance.| Keep the remote control close to the air conditioner and make sure the remote control is facing the remote control.
The battery has drained completely| Change battery.
Displays “El”| The tube temperature sensor senses an abnormal temperature.| Check the tube temperature sensor and related circuits.
Displays “E2”| The room temperature sensor senses an abnormal temperature.| Check the room temperature sensor and related circuits.

Need more information?

We hope that this user guide has given you the assistance needed for a simple setup.
For the most up-to-date guide for your product, as well as any additional assistance you may require,
head online to help.kogan.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals