Pureit G2 CLASSIC PURIFIER Instruction Manual

June 5, 2024
pureit

Pureit G2 CLASSIC PURIFIER

KNOW YOUR PUREIT CLASSIC G2 PURIFIER

  1. LED Indicator
  2. Tap
  3. Waste Water Tube
  4. Compound ESF Outlet Tube
  5. Water Level Indicator
  6. Compound ESF
  7. ESF Inlet Tube
  8. Diverter
  9. Ball Valve

UNIQUE FEATURES OF PUREIT CLASSIC G2 PURIFIER

Pureit G2 CLASSIC PURIFIER-fig3

PUREIT MAX WATER SAVER MINERAL RO+UV+MF PURIFIER’S ADVANCED PURIFICATION

PROCESS

Pureit RO Max water saver PURIFIER-fig4

This is a graphic representation of filters

  1. Pre Sediment
    Filter Removes visible dirt and impurities.

  2. Pre RO Carbon
    Filter Removes chlorine, harmful pesticides, bad taste and odour-causing organic compounds.

  3. Post Carbon
    Sediment Filter Removes any remaining impurities and dirt.

  4. RO Membrane
    Removes dissolved salts, hardness, pesticides and heavy metals like arsenic, lead and mercury, microbial contaminants like bacteria, virus, protozoa and cysts.

  5. UV Chamber^
    Additional stage of purication that destroys bacteria, virus and parasites.

  6. Micro Filtration (MF)
    Membrane^ Additional stage of purication to further purify water.

  7. Post RO Carbon Filter
    Acts as a polisher and enhances the taste of purified water

INSTALLING YOUR PUREIT CLASSIC G2 PURIFIER

  1. The purifier should be installed by a trained purifier technician.
  2. It can be wall-mounted or used as a table top purifier.
  3. The purifier should be placed in area which is free of ants/insects/other pests.
  4. The purifier should be placed close to the plumbed inlet connection (not more than 2 metres).
  5. Do not install the purifier above any electric socket.
  6. Avoid sharp bends to the pipes of the product.
  7.  Do not use an extension cord.
  8. Before installing the purifier please check the inlet pressure.
  9. Make sure you test the input water TDS (Total dissolved salts) before installing the purifier. The maximum input TDS should not exceed 2000 PPM.
  10. Do not connect the purifier to any hot water tap.
  11. Please do not terminate the reject line tubing directly into the drainage (keep it hanging over the drainage).
  12. Do not place the unit where it will be exposed to freezing and/or direct sunlight and ensure there is enough ventilation.

TAKING CARE OF YOUR PUREIT CLASSIC G2 PURIFIER

Cleaning

  1. Clean the tap nozzle using disinfectants like bleach/hypochlorite (50 PPM available chlorine). Discard 2 litres of water after cleaning the dispenser.
  2. Clean the external portion of the purifier using a dry cloth only. Do not use any detergent or soap.
  3. Do not clean aggressively or rub the surface as this might lead to scratches on the parts.
  4. Never splash water on the purifier while cleaning.
  5. Do not try to open the purifier for cleaning or for any replacements. This can be done only by a qualified company personnel or an authorised agent.
  6. You should maintain good hygiene in the area around your water purifier. Ensure that this area is free of ants/insects/other pests.
  7. Do take care of the reject line and other tubes while cleaning the purifier else water can ow into the kitchen.

Storage Tank

  1. Discard the water in the Storage Tank once in 15 days through the tap.
  2. Always drain the water in the Storage Tank if you have not used the purifier more than 2 days.
  3. Do not allow any foreign or unexpected material (like dust/ants/insects/other pests) to enter into the storage tank. The filtered water in the storage tank may deteriorate in the process.

Other Important Instructions

  1. When you are away / during over head tank cleaning always ensure to switch o the electrical power and the ball valve.
  2. Do not put any heavy or sharp objects on the purifier.
  3. Please dispose the used consumables like Sediment Filters, Carbon Filters and Membranes along with the other household waste through the municipal disposal system.
    Disposal Guidelines (Electrical): To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate electrical items in this product such as power supply adaptor, control circuits, LED panel and wiring from other types of waste and recycle them responsibly to promote sustainable use of material resources. Contact either the retailer where you purchased this product or local government oce for details of where and how these items can be taken for environmentally safe recycling.

KEEP YOURSELF SAFE

  1. Do not consume the water from the waste water tube for drinking purpose. However, you can use that water for gardening or cleaning the oors.
  2. Do not plug or unplug the power cord with wet hands. Ensure that the plug isn’t wet while plugging in, or plugging out to avoid risks such as electrical shock or re.
  3. Keep the cord away from wiring conjunctions to avoid hazard. Never put the cord under rugs, near heat resistors, radiators, stoves or heaters.
  4. If the power cord is damaged, the power cord must be replaced and not used.
  5. In case of any smoke or burning smell, remove the plug immediatey and call the Pureit Helpline.
  6. When shifting your house, get the purifier duly inspected and packed by the Pureit service technician. Remove water from the Storage Tank and pack the purifier properly in case of shifting.
  7. Please ensure to switch o the power whenever you turn o the Ball Valve.
  8. The point-of-use reverse osmosis drinking water treatment systems addressed by NSF-58 standard are designed to be used for reduction of specic substances that may be present in drinking water supplies (public or private) which are considered to be microbiologically safe and are of known quality.
  9. The output water may continue to have ora which are harmless and pose no health hazard to normal healthy adults and children.

UNIQUE ADVANCE ALERT SYSTEM

Pureit G2 CLASSIC PURIFIER-fig6

  • During the initial start up, the tank full LED and GKK LED will light up for 2 seconds. GKK LED will come on Red-Green-Blue
    sequence. The tank full LED will blink for max. 15 minutes and then restore to normal operation thereafter.

  • In case of any key electrical faults (RO Pump, UV Fault) GKK LED will start blinking Red-Green-Blue in sequence.

  • The blinking blue for sediment filter change will happen from approximately 165-180 days of clock time or 150-165 hours of
    pump running time,whichever is earlier, after device installation or GKK replacement. You can either clean the SF or call
    Pureit Helpline for buying a new SF at a nominal cost.

  • Approx. 330 hours of pump running time or 360 days of clock time, whichever is earlier the respective Germkill Kit needs to
    be changed. Approx. 330 hours of pump running time typically gives 6000 litres of purified water under test conditions of 10
    PSI input pressure. 750 ppm TDS and 25˚C temperature. In case of replacement. Variations from the test conditions could
    lead to variation in filtered water volume.

  • While the Germkill Kits and the Sediment Filter have a xed replacement schedule, you might be required to change the SF
    in the interim depending on the quality of your input water

TECHNICAL SPECIFICATIONS

Pureit G2 CLASSIC PURIFIER-fig7

  • 5.8 to 6.1 under running water conditions Permeate ow rate and recovery are based on standard test conditions and may vary depending on input water quality, TDS, pressure and life of Filter elements.
  • Input water quality and TDS content are important determinants of output water quality.
  • If input pressure exceeds 30 PSI, please install a company provided pressure reducing valve at an additional cost.
  • If the pressure is less than 10 PSI then you need to buy ‘Pressure enhancing pump’ at an additional cost.
  • Device should not be installed in a house where input pressure is greater than 60 PSI.
  • Post-RO Carbon Filter tted in the device may need to be changed intermittently at extra cost in case you face smell issues.
  • Technical specications are subject to change or improvement without prior notice.
  • In case the TDS is >1000 PPM, a company provided anti-scalant is recommended to be installed This has to be purchased at extra cost.
  • If the iron content in the input water is high, it is recommended to install a company provided iron removal lter at
    an additional cost. $ 7.6 to 8 litres in running water conditions at extra cost.

FAQs

  • How does Pureit Classic G2 purify water?
    Pureit Classic G2 has a 6-stage purication process which ensures you to get water that is ‘As Safe As Boiled Water’ and also removes excess Total Dissolved Solids (TDS) to make your water tastier.

  • Stage 1st
    Pre-Sediment Filter: Removes ne and coarse particulate impurities/dirt and improves the life of the Carbon Filter.

  • Stage 2nd:
    Pre-RO Carbon Filter: Removes chlorine and organic impurities like harmful pesticides. It also absorbs bad taste odour causing organic compounds from water.

  • Stage 3rd:
    Mini Filter: Filters water further to ensure removal of ner particulate impurities.

  • Stage 4th:
    RO Membrane: Removes dissolved salts, hardness, pesticides, uoride and heavy metals like arsenic, lead and mercury. It also removes microbial contaminants like bacteria, virus, protozoa and cysts.

  • Stage 5th:
    Micro Filtration Membrane(MF)/UV^: Micro Filtration Membrane (MF)/UV is added Post-RO, which ensures that the water is puried not once but twice.

  • Stage 6th:
    Post-RO Carbon Filter: Last level of purication acts as a polisher and enhances the taste of purified water.

  • What is the storage capacity of Pureit Classic G2?
    Pureit has Storage Tank capacity of upto 6L. The storage tank is fully automatic and well shielded and as and when you take water out of the tank, the purification process starts automatically again and rells the Storage Tank.

  • How much time does it take to purify water in Pureit Classic G2?
    Pureit can purify water upto 20 litres/hour depending on the device you have purchased. However, the time taken to purify depends on the life of the lters, the input water pressure, TDS and other impurities present in the water.

  • Does Pureit Classic G2 remove arsenic, uoride and nitrates?
    Like other ions, the RO technology can also remove arsenic, uoride and nitrates.

  • How will I get new consumables/membranes replaced?
    You need to call the Pureit Helpline and order the consumables. The customer care specialist will visit your place and replace the consumable/Germkill Kit at a nominal cost.

  • What are all the consumables which are to be replaced?
    You need to clean/replace Sediment Filter approximately every 6 months from the date of installation based on the input water quality conditions and GKK approximately every 1 year from date of installation.

  • Can I drink the rst purification cycle of water from the purier?
    No, recommendation is to throw the rst cycle of water that is lled in the Storage Tank when the new Pureit purifier is installed and also whenever the Germkill Kit are replaced.

  • Can I open and service my purier?
    It is not recommended to open and service purifier by an individual. Call our Pureit Helpline if you face any issue which requires servicing and opening of the purifier.

  • Can I use reject water?
    It is not recommended to use the reject water for any kind of human/pets consumption (drinking or cooking). It may be used for gardening or cleaning floors.

  • What should I do if any part of purifier is broken?
    Please call the Pureit Helpline. Our technicians will visit your house and guide you on the repairs required. There will be a nominal visiting charge and you would need to buy the parts required.

  • What should I do if there is leakage from the purifier?
    First switch o the Ball Valve if you nd any leakage from the purifier and turn o the power switch. Check for any visual improper tment and then call our Pureit Helpline number and register a service request.

  • How long the stored water in Pureit Classic G2 can be used for drinking?
    You can use stored water for 2 days. If it is not used for more than 2 days we advise you to discard that water, rell and then consume

Pureit Helpline
1860-210-1000
www.pureitwater.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

pureit User Manuals

Related Manuals