proceq Paperlink 2 Roll Testing Software Instruction Manual
- June 5, 2024
- proceq
Table of Contents
Paperlink 2 Roll Testing Software
Instruction Manual
Document Information
Document Revision:
Revision Date:
Document State:
Company:
Classification:| 1.2
–
Released
Proceq SA
Ringstrasse 2
CH-8603 Schwerzenbach
Switzerland Manual
---|---
Revision History
Rev | Date | Author, Comments |
---|---|---|
1 | Mar 14, 2022 | PEGG |
Initial document
1.1| Mar 31, 2022| DABUR,
product name updated (PS8000)
1.2| Apr 10, 2022| DABUR,
Images update and software name updated, redactional corrections
Legal Notices
This document can be changed without any prenotification or announcement.
The content of this document is the intellectual property of Proceq SA and is
prohibited from being copied neither in a photomechanical or electronic way,
nor in excerpts, saved, and/or passed on to other persons and institutions.
The features described in this instruction manual represent the complete
technology of this instrument. These features are either included in the
standard delivery or available as options at additional costs.
Illustrations, descriptions, and technical specifications conform to the
instruction manual at hand at the time of publishing or printing. However,
Proceq SA’s policy is one of continuous product development. All changes
resulting from technical progress, modified construction or similar are
reserved without obligation for Proceq to update.
Some of the images shown in this instruction manual are of a pre-production
model and/or are computer-generated; therefore the design/features on the
final version of this instrument may differ in various aspects.
The instruction manual has been drafted with the utmost care. Nevertheless,
errors cannot be entirely excluded. The manufacturer will not be liable for
errors in this instruction manual or for damages resulting from any errors.
The manufacturer will be grateful at any time for suggestions, proposals for
improvement, and references to errors.
Introduction
Paper Schmidt
The Paper Schmidt PS8000 is a precision instrument designed for testing roll
profiles of paper rolls with a high degree of repeatability.
Paperlink Software
Starting Paperlink 2
Download the Paperlink 2 from
https://www.screeningeagle.com/en/products/Paper Schmidt and locate the file
“Paperlink2_Setup” on your computer
Follow the instructions you see on the screen. This will install Paperlink 2on
your PC including the necessary USB driver. It will also create a desktop icon
for launching the program.
Either click on the desktop icon or click on the Paperlink 2 entry in the
“Start” menu. “Start – Programs –Proceq –Paperlink 2”.
Click on the “Help” icon to bring up the complete operating instructions.
Application settings
The menu item “File – Application settings” allows the user to select the
language and the date and time format to be used.
Connecting to the Paper Schmidt
Connect your Paper Schmidt to a free USB port, then click on the icon to bring
up the following window:
Leave the settings as default or if you know the COM port you can enter it
manually.
Click on “Next >”
The USB driver installs a virtual com port which is used to communicate with
the Paper Schmidt. When a Paper Schmidt has been found you will see a window
like this: Click on the “Finish” button to establish the connection.
Viewing the data
The data stored on your Paper Schmidt will be displayed on the screen:
- The test series is identified by the “Impact counter” value and by a “Roll ID” if assigned.
- The user may alter the Roll ID directly in the “Roll ID” column.
- The “Date & Time” when the measurement series was made.
- The “Mean value”.
- The “Total” number of impacts in this series.
- The “Lower limit” and “Upper limit” are set for that series.
- The “Range” of the values in this series.
- The “Std dev.” The standard deviation of the measurement series.
Click on the double arrow icon in the impact counter column to see the profile.
PaperLink – Manual
The user may also add a comment to the measurement series. To do so, click on
“Add”.
The user may alter the order in which the measurements are shown. Click on
“measurement order” to switch to “ordered by value”.
If limits have been set, they are displayed as follows with a blue band. It is also possible to adjust the limits directly in this window by clicking on the blue limit values.
In this example, the third reading can be clearly seen to be outside the limits.
Summary window
In addition to the “Series” view described above, Paperlink 2 also provides
the user with a “Summary” window. This may be useful when comparing a batch of
rolls of the same type.
Click on the respective tab to switch between views.
To include or exclude a series from the summary, click on the summary symbol in the impact counter column. This symbol is either “black” or “greyed out”, which shows whether or not the particular series is included in the summary. The summary view can be adjusted in a similar way to the detailed view of a series.
Adjusting the max/min settings
Maximum and Minimum settings that were used in the Paper Schmidt at the time
of the measurement series can be adjusted subsequently in Paperlink 2.
This can be done either by right-clicking directly on the item in the
appropriate column or by clicking on the blue setting item in the detailed
view of a measurement series.
In each case, a selection box will appear with the choice of setting.
Adjusting the date and time
The time will be adjusted for the selected series only.
Exporting data
Paperlink 2 allows you to export selected series or the entire project for use
in third-party programs.
To export the selected series, click on the table of the measurement series
you wish to export. It will be highlighted as shown.
Click on the “Copy as text” icon.
The data for this measurement series is copied to the clipboard and can be
pasted into another program such as Excel. If you wish to export the
individual impact values of the series, you have to display them by clicking
on the double arrow icon as described above before you “Copy as text”.
Click on the “Copy as picture” icon
For exporting the selected items only into another document or report. This
performs the same action as above, but the data is exported in the form of a
picture and not as text data.
Click on the “Export as text” icon
Allows you to export the entire project data as a text file that can then be
imported into another program such as Excel. Click on the “Export as text”
icon.
This will open the “Save As” window where you can define the location in which
you wish to store the *.txt file.
Give the file a name and click on “Save” to save it.
Paperlink 2 has two “tabs” with two display formats. “Series” and “Summary”.
When performing this operation, the project data will be exported in the
format defined by the active “Tab”, i.e. either in “series” or “summary”
format.
To open the file in Excel, locate the file and right-click on it, and “Open
with” – “Microsoft Excel”. The data will be opened in an Excel document for
further processing. Or drag and drop the file into an open Excel window.
Deleting and restoring data
The menu item “Edit – Delete” allows you to delete one or more selected series
from the downloaded data.
This does not delete data from the Paper Schmidt, only data in the current
project.
The menu item “Edit – Select all”, allows the user to select all series in the
project for exporting etc.
Restoring the original downloaded data
Select the menu item: “File – Restore all original data” to restore the data
to the original format as it was downloaded. This is a useful feature if you
have been manipulating the data, but wish to go back to the raw data once
again.
A warning will be given to say that the original data is about to be restored.
Confirm to restore.
Any names or comments that have been added to the series will be lost.
Deleting data stored on the Paper Schmidt
Select the menu item “Device – Delete all Data on Device” to delete all data
stored on the Paper Schmidt.
A warning will be given to say that the data is about to be deleted on the
device. Confirm to delete.
Please note, that this will delete every measurement series and cannot be
undone. It is not possible to delete individual series.
**Further Functions
**
The following menu items are available via the icons at the top of the screen:
“Upgrade” icon
Allows you to upgrade your firmware via the Internet or from local files.
“Open project” icon
Allows you to open a previously saved project. It is also possible to drop a
*.pqr file onto
Paperlink 2 to open it.
“Save project” icon
Allows you to save the current project. (Note this icon is greyed out if you
have opened a
previously saved project.
“Print” icon
Allows you to print out the project. You may select in the printer dialog if
you want to print out all of the data or selected readings only.
**Technical Information Paperlink 2 software
**
System requirements: Windows XP, Windows Vista or newer, USB-Connector
An Internet connection is necessary for automatic updates, if available.
An Internet connection is necessary for firmware updates (using PqUpgrade), if
available.
PDF Reader is required to show the “Help Manual”.
For safety and liability information, please check
www.screeningeagle.com/en/legal
Subject to change. Copyright © Proceq SA. All rights reserved.
EUROPE
Proceq AG
Ringstrasse 2
8603 Schwerzenbach
Zurich | Switzerland
T +41 43 355 38 00| MIDDLE EAST AND AFRICA
Proceq Middle East and Africa
Sharjah Airport International
Free Zone | P.O.Box: 8365
United Arab Emirates
T +971 6 5578505
---|---
UK
Screening Eagle UK Limited
Bedford i-lab, Stannard Way
Priory Business Park
MK44 3RZ Bedford
London | United Kingdom
T +44 12 3483 4645| SOUTH AMERICA
Proceq SAO Equipamentos de Mediçao Ltda.
Rua Paes Leme 136
Pinheiros, Sao Paulo
SP 05424-010 | Brasil
T +55 11 3083 3889
USA, CANADA & CENTRAL AMERICA
Screening Eagle USA Inc.
14205 N Mopac Expressway Suite 533
Austin, TX 78728 | United States| CHINA
Proceq Trading Shanghai Co., Limited
Room 701, 7th Floor, Golden Block
407-1 Yishan Road, Xuhui District
200032 Shanghai | China
T +86 21 6317 7479
Screening Eagle USA Inc.
117 Corporation Drive
Aliquippa, PA 15001 | United States
T +1 724 512 0330| ASIA-PACIFIC
Proceq Asia Pte Ltd.
1 Fusionopolis Way
Connexis South Tower #20-02
Singapore 138632
T +65 6382 3966
© Copyright 2022, PROCEQ SA
Documents / Resources
|
proceq Paperlink 2 Roll Testing
Software
[pdf] Instruction Manual
Paperlink 2, Roll Testing Software, Paperlink 2 Roll Testing Software
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>