Danfoss FP720 Two Channel Timer User Guide
- June 11, 2024
- Danfoss
Table of Contents
FP720 Two Channel Timer
User Guide
FP720 Two Channel Timer
What is the FP720 Timer?
The FP720 is used to switch your heating and hot water at times to suit you.
The FP720 has made setting your on/off times easier than ever before.
Setting Time and Date
a. Press and hold the OK button for 3 seconds, the screen will change to show
the current year.
b. Adjust using or to set the correct year. Press OK to accept. Repeat step b
to set month and time settings.
On/Off Schedule Setup
The FP720 Timer Function allows you to set a timer-controlled program for your
heating and hot water.
See the example below to program for a 5/2 day setup (Monday-Friday & Sat-
Sunday)
a. Press button to access schedule setup.
b. Press the PR to choose between SET CH1, SET HW or between SET CH1, SET CH2
( if menu option P3 is set to 02) and press OK to confirm.
c. Mo. Tu. We. Th. Fr. will flash on the display.
d. You can select weekdays (Mo. Tu. We. Th. Fr.) or weekend (Sa. Su.) with or
buttons.
e. Press OK button to confirm days selected (e.g. Mon-Fri) The chosen day and
1st ON time is displayed.
f. Use or to select ON hour, press OK to confirm.
g. Use or to select ON minute, press OK to confirm.
h. Now the display changes to show the “OFF” time
i. Use or to select OFF hour, press OK to confirm.
j. Use or to select OFF minute, press OK to confirm.
k. Repeat steps f. to j. above to set 2nd ON, 2nd OFF, 3rd ON & 3rd OFF
events. Note: the number of events is changed in User Settings menu P2 (see
table)
l. After the last event time is set, if you were setting Mo. to Fr. the
display will display Sa. Su.
m. Repeat steps f. to k. to set Sa. Su.
n. After accepting Sa. Su. final event setting your FP720 will return to
normal operation.
If your FP720 is set for 7 day operation, the option will be given to select
each day separately. In 24 hr mode, option will only be given to select Mo. to
Su. together. To change this setting. see User Settings menu P1.
Where the FP720 is set for 3 periods, options will be given to select period 3
times. In 1 Period mode, option will be only given for one ON/OFF time. See
user setting menu P2.
Display and Navigation Details
Display & Navigations
Symbols| Function description| Symbols| Function
description
---|---|---|---
Mon–Sun| Current set day| | Domestic hot water heating active
| Current on/off period| | Holiday mode
SET CH1 CH2 HW ON OFF| Schedule setup| | Schedule setup (menu access)
| Current set time/parameter setup| OK| Confirm settings
(Date and time setup)
(Reset)
Day Mth Yr Hr Min| Time and date setup| | Menu navigation/day selection
(AUTO+1HR function)
| Heating active (1 or 2 Zone)| | Time and setting changes/channel mode
selection
CH1
AUTO +1HR ON OFF| Heating channel 1 current mode| PR| Programmable
channel selection (Holiday mode selection)(Reset)
CH2HW
AUTO +1HR ON OFF| Heating channel 2 or DHW current mode| –| –
- To access additional feature press and hold button for 3 seconds.
To reset the timer, press and hold the PR and OK buttons for 10 seconds. The reset is complete after ConF text appear on the display.
(Note: This does not reset service due timer or date and time settings.)
Holiday Mode
Holiday Mode temporarily disables the timing functions when away or out for a
period of time. (see User Settings menu P6)
a. Press PR button for 3 seconds to enter Holiday mode. icon will be shown on
the display.
b. Press PR button again to resume normal timings.
Channel Override
You can override the heating / hot water channels between AUTO, AUTO+1HR, ON
and OFF
a. Press the PR button and the selected channel will flash, along with the
current mode (AUTO etc).
b. Use or to select required option (AUTO+1HR, ON, OFF etc) and press OK to
select.
c. To alter the other channel (i.e. HW) press the PR button until the HW
channel is flashing.
d. Repeat step B to select operating mode.
Boost (AUTO+1HR) Function
a. To boost either heating or hot water channel for 1 hour press and hold the
or button for 3 seconds according to channel boost requirement.
b. With this selected, the heating/hot water will remain ON for an extra hour.
If it is selected while the programmed is OFF, the heating/hot water will
switch ON immediately for 1 hour then resume programmed time (AUTO mode)
again.
User Settings
a. Press for 3 seconds to enter the parameter setting mode. set the option
range via or .
b. To exit User Settings press or after 20 seconds if no button is pressed,
unit will return to main screen.
No. | Parameter settings | Settings range | Default |
---|---|---|---|
P1 | Working mode | 1: Schedule timer 7 day |
2: Schedule timer 5/2 day
3: Schedule timer 24hr| 02
P2| Schedule periods| 1:1 period (2 events)
2:2 periods (4 events)
3:3 periods (6 events)| 02
P3| Channel setup| 1: Heating + Domestic hot water
2: Two heating zones| 01
P4| Timer display| 1: 24hr
2: 12hr| 01
P5| Auto daylight saving| 01: 0n
02: Off| 01
P6| Holiday mode setup| 1: All channels off
2: Heating off only| 01
P7| Service due setup| Installer setting only|
Danfoss A/S
Heating Segment
danfoss.com
+45 7488 2222
E-mail: heating@danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues,
brochures and other printed material. Danfoss reserves the right to alter its
products without notice. This also applies to products already on order
provided that such alterations can be made without sub sequential changes
being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logo- type are trademarks of Danfoss A/S. All rights
reserved.
© Danfoss | FEC | 10.2020
www.danfoss.com
BC337370501704en-000104
087R1004
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>